The MidOpt BN880 is a bandpass filter from the BN Series (narrow bandwidth), with a useful range of 855-890nm and an FWHM of 45nm. Peak transmission is listed at ≥85% and surface quality at 40/20. The manufacturer designs it for 880nm infrared illumination and notes that it is suitable when other lighting wavelengths are also present. That second point is the practical one: the manufacturer positions it for scenes where other lighting wavelengths are also present, since the passband limits what reaches the camera outside 855-890nm.
The BN880 is offered in 24 threaded size options from M13.25 to M82, with 25.4® C-Mount, slip mount and unmounted/custom sizes also available. The threaded range ends at M82, so the lens filter thread should be checked against it before ordering. The 25.4® C-Mount and slip mount formats are the alternatives for other holder formats.
Pairing starts with the 880nm illuminator, which should sit inside the 855-890nm useful range, and the camera sensor needs to respond at 880nm. The 45nm FWHM is the passband width at half maximum, so keeping the source well inside the range protects signal. Because other lighting wavelengths may be present, the installer should verify with the full lighting setup in place that the unwanted wavelengths fall outside the passband. The ≥85% peak transmission belongs in the exposure budget.
Best for
Imaging with 880nm infrared illumination
Scenes where other lighting wavelengths are present, a use case the manufacturer cites
Lens-mounted filtering in 24 threaded sizes (M13.25–M82)
Installations that need a 45nm FWHM passband around 880nm
Selection notes
Set the 880nm illuminator inside the 855-890nm useful range, not at an edge.
Because other lighting wavelengths may be present, test with the full lighting setup to confirm the passband isolates the intended source.
Check that the lens filter thread falls within the 24 threaded sizes (M13.25–M82), or use the 25.4® C-Mount or slip mount formats.
Plan exposure around the ≥85% peak transmission.
Specifications: General
Brand
MidOpt
Specifications: Optical
Filter type
Bandpass
Filter wavelength
855-890nm (useful range), FWHM 45nm
Specifications: Mechanical
Thread / filter size
M13.25–M82 (24 threaded size options)
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Availability
25.4® C-Mount (threads between lens & sensor) / threaded M25.4 Base