Skip to content
MidOpt BP695 Near-IR Bandpass Filter machine vision optical filter
  • Rosepetal compatible
  • Recommended by AIS Vision

BP695 Near-IR Bandpass Filter

BP695

MidOpt BP695 Near-IR Bandpass Filter — Bandpass filter (BP Series - Broad Bandwidth): useful range 680-720nm, FWHM 70nm, peak transmission ≥90%, surface quality 40/20. Available as 27 threaded size options (M13.25–M105), 25.4® C-Mount, slip mount, unmounted/custom sizes.

Brand
MidOpt
Filter type
Bandpass
Filter wavelength
680-720nm (useful range), FWHM 70nm
Thread / filter size
M13.25–M105 (27 threaded size options)

Technical overview

The MidOpt BP695 Near-IR Bandpass Filter is a member of the BP Series, with a useful range of 680-720nm, an FWHM of 70nm and a peak transmission of ≥90%. The manufacturer recommends it for use with near-infrared LEDs, and also for imaging weak luminescence of subjects excited with a red LED light. The passband runs from 680nm to 720nm, spanning the deep red and near-infrared region.

The luminescence use case describes an excitation-and-emission arrangement: a red LED excites the subject and the weak emitted light is imaged. In that setup the filter passes the emitted light inside the 680-720nm window, and the excitation light should sit outside that window so it does not reach the camera. The 70nm FWHM describes the width of the transmitted band at half its peak, and the ≥90% peak transmission limits the loss of the weak signal within the band. Because the signal is weak, exposure settings and lighting power matter as much as the filter itself.

The filter is listed in 27 threaded size options from M13.25 to M105, along with 25.4® C-Mount, slip mount, and unmounted or custom sizes. The surface quality is given as 40/20. Select the mount that matches the lens or housing and the illumination arrangement in your system.

Best for

  • Imaging weak luminescence from subjects excited by red LED light
  • Near-infrared LED illumination work in the 680-720nm band
  • Excitation-and-emission setups with a red LED excitation source and emitted light inside 680-720nm
  • Lens-front integration using threaded sizes from M13.25 to M105
  • Applications that need a 680-720nm passband with a 70nm FWHM

Selection notes

  • Confirm that the red excitation LED sits outside the 680-720nm passband so the excitation light does not reach the camera.
  • Match near-infrared LED sources to the 680-720nm useful range.
  • Weak signals call for planning exposure and lighting power with the ≥90% peak transmission in mind.
  • Choose the threaded size, or the C-Mount, slip-mount, or custom option, that fits your optical train.
  • Check the listed surface quality of 40/20 against your application requirements.

Specifications: General
BrandMidOpt

Specifications: Optical
Filter typeBandpass
Filter wavelength680-720nm (useful range), FWHM 70nm

Specifications: Mechanical
Thread / filter sizeM13.25–M105 (27 threaded size options)

Frequently asked questions

Related technical guides

Often used with

C-mount lenses

Check the lens filter thread before choosing the filter size.

All C-mount lenses →

Rosepetal · AI

Test this camera with Rosepetal

Validate your visual inspection with AI: send us sample images and we evaluate the case on your hardware.

AIS Vision · Integration

We validate camera + lens + lighting

AIS Vision defines and tests the optimal combination of camera, optics and lighting for your application before you buy.