The MidOpt DB660/850 is a dual bandpass filter with a red window at 645–675 nm and a near-infrared window at 830–870 nm, both given as useful range. The manufacturer states it was designed primarily for NDVI imaging applications. NDVI, the Normalized Difference Vegetation Index, is calculated from red and near-infrared reflectance, which are the two bands this filter passes.
The FWHM values are 40 nm and 50 nm, peak transmission is ≥90%, and surface quality is 40/20. The filter is available in 23 threaded size options from M13.25 to M82, as 25.4® C-Mount, as a slip mount, and in unmounted/custom sizes. Light outside 645–675 nm and 830–870 nm is blocked, which limits the influence of ambient light on the red and NIR channels.
Installation depends on the camera and the illumination. The sensor needs to respond in both the red and the 830–870 nm windows, and the illumination should peak inside those windows. Because the filter passes only these two bands, each channel carries signal only from its own band, which is the red and near-infrared pairing that NDVI workflows use.
Best for
NDVI imaging of vegetation, the application the manufacturer names as its primary design target
Multispectral imaging that combines red and near-infrared channels through one lens
Plant-health and crop-monitoring setups that need red and NIR signal from the same scene
Ambient-light-limited imaging where only the 645–675 nm and 830–870 nm bands should reach the sensor
Lens retrofits that use a threaded M13.25–M82 filter or a 25.4® C-Mount filter
Selection notes
Confirm the sensor responds in both 645–675 nm and 830–870 nm, since both windows are needed for a two-band NDVI-style channel.
Use the FWHM values of 40 nm and 50 nm to judge how narrow each passband is when matching the illumination to the windows.
Select a mount from the 23 threaded sizes (M13.25–M82), 25.4® C-Mount, or slip mount, or request unmounted/custom sizes.
Plan exposure around the peak transmission of ≥90%.