The MidOpt LP590 Red Longpass Filter is in the MidOpt LP Series, with a listed useful range of 605-1100nm. The manufacturer describes it as passing red and near-infrared (NIR) light while blocking the remaining visible and UV wavelengths. Installed in front of a camera, the filter limits the image to red light from 605nm and the NIR region up to 1100nm. That suits setups where the scene should be read mainly through its red and NIR content rather than its broadband visible light.
Peak transmission is at least 90% (≥90%) and the listed surface quality is 40/20. The high transmission keeps light within the 605-1100nm band largely intact, so the main effect is the removal of everything else. Because that removal is strong, the sensor receives a smaller share of the scene's light, and exposure, gain and lighting power should be re-set after installation. The illumination itself should be in the red or NIR band, since light below 605nm is blocked.
Mounting options are 27 threaded size options from M13.25–M105, a 25.4® C-Mount format, a slip mount, and unmounted or custom sizes. Match the threaded size to the lens filter thread, or use the slip mount or unmounted or custom version for a housing that does not follow a standard thread. The mount sets where the filter sits relative to the lens, so it should be decided early in the design.
Best for
Passing red and NIR light while blocking the remaining visible and UV content in the camera path
Red illumination setups where ambient visible light must be suppressed
Imaging with NIR light sources whose output sits within the 605-1100nm band
Retrofitting lenses or housings that use one of the 27 threaded sizes from M13.25–M105
Selection notes
Choose the mount from the listed options: 27 threaded size options from M13.25–M105, 25.4® C-Mount, slip mount, and unmounted/custom sizes.
Confirm that the illumination falls within the 605-1100nm useful range. Red sources with output below 605nm will be attenuated.
Re-set exposure and lighting power after installation. The passband is kept at ≥90% peak transmission, but removing the remaining visible light reduces the total light reaching the sensor.
Check the 40/20 surface quality against the optical requirement of the application, especially for measurement tasks.
Specifications: General
Brand
MidOpt
Specifications: Optical
Filter type
Longpass
Filter wavelength
605-1100nm (useful range)
Specifications: Mechanical
Thread / filter size
M13.25–M105 (27 threaded size options)
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Availability
25.4® C-Mount (threads between lens & sensor) / threaded M25.4 Base