Opto Engineering CBSLH-24V-F LED illuminator cable, JST SM 3 way female connector to Flying leads
CBSLH-24V-F
Opto Engineering CBSLH-24V-F — Cables for LED illuminators: type Power, side 1 JST SM 3 way female connector, side 2 Flying leads; length 3 m (CBSLH-24V-F-3M), 5 m (CBSLH-24V-F-5M).
A two-conductor power feed for a broad group of illuminators: LTBCL, LTBFC, LTBRDC, LTCXC, LTDMC, LTLADC, LTLAIC, LTRNDC and LTTNC series. The cable type is power only, with two poles behind a JST SM 3-way female connector, so it carries the 24 V supply and nothing else. Any trigger, strobe or intensity control has to reach the light by another route, so check how your illuminator is switched before choosing it.
In 24 AWG (typically about 84 mΩ/m) the 5 m version has a loop resistance of 2 × 5 m × 0.084 Ω/m ≈ 0.84 Ω, so at its rated 2.0 A it loses about 1.7 V (0.84 Ω × 2.0 A), against about 1.0 V for the 3 m version (2 × 3 m × 0.084 Ω/m × 2.0 A). A lighter load loses proportionally less. The jacket is 4 mm with a 14 mm minimum bending radius.
Best for
Illuminators from the nine series above that are fed from a plain 24 V rail in the cabinet and switched there, with no separate signal wire.
Cramped brackets and small enclosures, where a 4 mm jacket with a 14 mm bending radius turns corners that a thicker cable would not.
Lights near warm equipment or in cool halls: the PVC jacket is rated -25 to +80 °C, a wider band than the 0 to +40 °C of the CBLT015 lighting cable.
Selection notes
Check the series against your illuminator before ordering; LTRNOB and LTRNST lights use the terminal-block version, CBSLH-24V-F-3M-TB, instead.
Choose 3 m or 5 m from the real route; the 5 m version loses about 0.7 V more at the full 2.0 A rating.
The cable is unshielded: route it apart from motor and drive wiring.
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Not with a signal: it has two conductors and no signal line. Switching has to be done on the 24 V supply or through a separate input on the illuminator, if it has one.
No: it is IP20, for protected locations only. Choose an illuminator that takes an IP67 cable such as CBLTM12-5P (LT2PRUP, LT2PRXP, LT3BC and LTSP series).