The Basler CXP-12 Interface Card 1C is a frame grabber for CoaXPress (CXP-12) with one camera port. Basler describes a maximum bandwidth of 12.5 Gbps via a 1-channel Micro-BNC (HD BNC) connection, and the card connects to the PC via PCIe 3.0 x4. Power over cable is PoCXP (17W/24V per connector), so a PoCXP camera can be powered through the same coax cable.
On the card are a Xilinx Ultrascale+ KU3P on-board processor and 1 GByte DDR4-RAM of on-board memory. GPIO is 4 in/2 out (max.), TTL or opto-coupled, with differential or single-ended signals depending on configuration. Software support covers Linux 64-Bit and Windows 11 / 10 (64-Bit), with the Framegrabber SDK, GenTL and pylon SDKs.
Mechanically it is a PCIe Standard height, low profile card: 167.64 mm length x 68.9 mm height, weighing 170 g. Power consumption is Typ. 13,4W@12V, excluding camera and I/O power output, so the PC power budget should add whatever the camera draws through PoCXP. The operating temperature range is 0 - 50 °C (32 - 122 °F).
Best for
Single-camera CoaXPress (CXP-12) acquisition at a maximum bandwidth of 12.5 Gbit/s
PCs with room for a PCIe Standard height, low profile card (167.64 mm x 68.9 mm)
Stations that need the GPIO lines (4 in/2 out max., TTL or opto-coupled)
Applications built on the pylon SDKs, GenTL or the Framegrabber SDK under Linux 64-Bit or Windows 11 / 10
Installations that power the camera over the coax cable via PoCXP (17W/24V per connector)
Selection notes
Use it with CoaXPress (CXP-12) cameras; the card has one camera port.
Include the camera's PoCXP draw in the PC power budget, since the card's Typ. 13,4W@12V figure excludes camera and I/O power output.
Check that the PC has a PCIe slot for PCIe 3.0 x4 and fits a low profile card of 167.64 mm length x 68.9 mm height.
Plan the GPIO wiring (TTL or opto-coupled, differential or single-ended depending on configuration) against the 4 in/2 out (max.) lines.
Confirm software support: Linux 64-Bit or Windows 11 / 10 (64-Bit), with the Framegrabber SDK, GenTL or pylon SDKs.
Specifications: General
Brand
Basler
Card type
Frame grabber
Specifications: Performance
Total bandwidth
12.5 Gbit/s
On-board processing
Xilinx Ultrascale+ KU3P
On-board memory
1 GByte DDR4-RAM
Specifications: Interface
Interface
CoaXPress (CXP-12)
Camera ports
1
PC bus
PCIe 3.0 x4
Trigger / GPIO
4 in/2 out (max.), TTL or opto-coupled; differential or single-ended signals (configuration dependent)
Specifications: Electrical
Power over cable (PoE / PoCXP / PoCL)
PoCXP (17W/24V per connector)
Power consumption
Typ. 13,4W@12V, excluding camera and I/O power output
Specifications: Environment
Operating temperature
0 - 50 °C (32 - 122 °F)
Specifications: Software
Operating systems
Linux 64-Bit; Windows 11 / 10 (64-Bit)
Software / API
Framegrabber SDK; GenTL; pylon SDKs
Specifications: Mechanical
Dimensions
PCIe Standard height, low profile card: 167.64 mm length x 68.9 mm height
Weight
170 g
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
Matched automatically by: camera interface matches the card (coaxpress) · card link speed is at least the camera link speed (cxp-6 / cxp-12, 1–10 gige) — this card: CoaXPress (CXP-12) · 1 camera port.
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
It has 1 camera port, with a maximum bandwidth of 12.5 Gbit/s via a 1-channel Micro-BNC (HD BNC) connection.
Yes. Power over cable is PoCXP (17W/24V per connector).
It has a Xilinx Ultrascale+ KU3P on-board processor and 1 GByte DDR4-RAM of on-board memory.
Linux 64-Bit and Windows 11 / 10 (64-Bit), with the Framegrabber SDK, GenTL and pylon SDKs.
GPIO of 4 in/2 out (max.), TTL or opto-coupled, with differential or single-ended signals depending on configuration.