Skip to content
Datalogic Matrix 220 STD 7 mm machine vision code reader
  • Recommended by AIS Vision

Datalogic Matrix 220 compact 2D imager, standard optics 7 mm

Matrix 220 STD 7 mm

Datalogic Matrix 220 STD 7 mm — fixed-mount industrial reader; 2D imager; 1.2 MP; 7 mm optics; reads 40–400 mm; 45 fps; IP65, IP67; interfaces Ethernet / RS-232 / PROFINET / EtherNet/IP / Modbus TCP / Digital I/O; operating 0 to 50 °C (datalogic.com); datasheet: 0 to 50 °C for the "X" P/Ns, -10 to 50 °C for the other P/Ns. 3 order codes on datalogic.com.

Brand
Datalogic
Reader type
Code reader
Form factor
Compact fixed-mount 2D imager
Scan technology
2D imager, 1/3" CMOS global shutter
Resolution
1.2 MP (1280 × 960 px)
Horizontal resolution
1280 px
FPS
45 frames/s
Focal length
7 mm
Field of view
Viewing angle 38.3° (7 mm optics)
Focus
Electronic focus control (remote focus change)
Min. code resolution
up to 2 mils (multicore platform)
Verification standards
Code quality metrics: 1D ISO/IEC 15416; 2D ISO/IEC 16022/18004, ISO/IEC 29158 (AIM-DPM), ISO/IEC 15415

Technical overview

On the 7 mm optics the 38.3° view, taken as horizontal, gives a field of about 0.69 × distance (2 × tan 19.15° ≈ 0.695): 28 mm wide at 40 mm and 278 mm at the 400 mm limit. One pixel covers 27.8 ÷ 1280 ≈ 0.022 mm at 40 mm and 278 ÷ 1280 ≈ 0.22 mm at 400 mm, so a 2 mil (0.051 mm) module gets only 0.051 ÷ 0.0217 ≈ 2.3 px at 40 mm. To use the platform's 2 mil capability, the 12 mm optics give 0.051 ÷ 0.0133 ≈ 3.8 px at the same distance and are the better fit.

Light is fixed by the order code: red high-power for Digimarc (322-01A), a PoE code (352-040) and an ultraviolet high-power code (3U2-01U, STD-UV 7MM HP), whose UV illuminator typically suits marks that fluoresce under UV. No polarizer is fitted. Electronic focus control allows remote changes of working distance, and ESD-safe and anti-YAG front covers are available as accessories.

Best for

  • Large labels or several codes in one frame at 40–400 mm, where a 38.3° view covers more than the 12 mm optics' 24.1°.
  • UV-reactive marks, read through the UV high-power illuminator of the 3U2-01U code.
  • Installations with a single cable run, using the 352-040 PoE code (M12 5-pin plus Ethernet PoE).

Selection notes

  • The reading range stops at 400 mm; the 12 mm version reaches 600 mm at 24.1°, with a smaller pixel footprint at the same distance.
  • The PoE code has 1 input, no outputs and only the auxiliary RS-232, so plan for results over Ethernet.
  • For glossy parts that reflect the illuminator back, the Matrix 220 DPM 7 mm embeds a polarizer and diffuser, but reads 40–300 mm instead of 40–400 mm.

Specifications: General
BrandDatalogic
Reader typeCode reader
Form factorCompact fixed-mount 2D imager

Specifications: Sensor
Resolution1.2 MP (1280 × 960 px)
Horizontal resolution1280 px

Specifications: Performance
FPS45 frames/s

Specifications: Interface
CommunicationEthernet 10/100 (TCP/IP, UDP, FTP, PROFINET IO, EtherNet/IP, Modbus TCP, OPC UA) + RS-232/RS-422 FD main + aux RS-232; PoE models: Ethernet PoE (Mode A / B) + aux RS-232; ID-NET; 2 inputs / 3 outputs (PoE models: 1 input, no outputs)
ConnectionM12 17-pin + Ethernet; PoE models: M12 5-pin + Ethernet PoE

Specifications: Optical
Focal length7 mm
Field of viewViewing angle 38.3° (7 mm optics)
FocusElectronic focus control (remote focus change)
Integrated lightingStandard white light, white high-power light, red high-power light (Digimarc -01A model) or ultraviolet high-power light; no polarizer
Illumination colourRed / White / Ultraviolet (per order code)

Specifications: Electrical
Power over cable (PoE / PoCXP / PoCL)PoE (Mode A and Mode B, 48 VDC) on the -040 POE order codes
Supply voltage10 – 30 VDC (all models except PoE); 48 VDC PoE
Power consumption4.2 W max (10 – 30 VDC); 4.8 W max (PoE models, 48 VDC)

Specifications: Environment
Operating temperature0 to 50 °C (datalogic.com); datasheet: 0 to 50 °C for the "X" P/Ns, -10 to 50 °C for the other P/Ns
IP ratingIP65, IP67

Specifications: Reading
Scan technology2D imager, 1/3" CMOS global shutter
Min. code resolutionup to 2 mils (multicore platform)
Verification standardsCode quality metrics: 1D ISO/IEC 15416; 2D ISO/IEC 16022/18004, ISO/IEC 29158 (AIM-DPM), ISO/IEC 15415
Read distance40 – 400 mm (STD-W, STD-W HP and STD-UV HP, 7 mm lens)
Supported codes1D: all standard symbologies; 2D: Data Matrix, QR Code, Micro QR, Maxicode, Aztec, Dot Code; postal: Royal Mail, Japan Post, Planet, Postnet and more; Digimarc Barcode (DWCODE)

Specifications: Mechanical
Dimensions78 x 47 x 38 mm (connector at 0°); 57 x 47 x 58 mm (connector at 90°)
Weight173 g
Housing materialAluminium case, plastic protective window cover

Frequently asked questions

Related technical guides

Often used with

Ethernet / GigE cables

Industrial Ethernet / GigE cables with locking connectors. Check length and flex rating against your installation.

All cables →

I/O and power cables

Industrial I/O and power cables with locking connectors. Check length and flex rating against your installation.

All cables →

Mounts and housings

Brackets and protective housings to fix and protect the device on the line.

All mounts and housings →

AIS Vision · Integration

We validate camera + lens + lighting

AIS Vision defines and tests the optimal combination of camera, optics and lighting for your application before you buy.