The iRAYPLE AH3B07CU000E is a 20 MP color camera on a GMAX2424 sensor, listed in a 1 inch CMOS format. It outputs 5472 × 3648 px at up to 19.2 fps in Bayer RG 8, so the host software must convert each frame to RGB. The shutter is listed as Rolling/GlobalResetRealease. For stationary or slow-moving subjects, the full 20 MP frame at 19.2 fps gives a useful balance of detail and throughput.
The USB 3.0 interface connects directly to a PC with a USB 3.0 port, with no frame grabber required. Power can come from the USB connection or from a DC supply of 9 V to 24 V through a Hirose connector, and the listed draw is 3.3 W. The body measures 29 mm × 29 mm × 30 mm (excluding lens mount and rear case connector), weighs 85 g, and is specified for -30 °C to +50 °C operation.
For optics, the C-mount takes a standard C-mount lens, and the image circle must cover the 1 inch CMOS format at 20 MP. This model suits high-resolution color inspection where 19.2 fps at 20 MP is needed and a PC-based USB 3.0 setup is preferred.
Best for
High-resolution color inspection at 20 MP and up to 19.2 fps
USB 3.0 PC-based systems that need 19.2 fps at 20 MP
Color verification where Bayer RG 8 output is converted to RGB on the host
Compact (29 mm × 29 mm × 30 mm) installations across a -30 °C to +50 °C range
Selection notes
Verify the exposure behavior of the Rolling/GlobalResetRealease shutter on your own moving parts before committing this camera to them.
Size the host for 20 MP: at 5472 × 3648 px and 19.2 fps, the PC, its USB 3.0 controller and the cable need to sustain the data rate, so test on target hardware.
Plan the debayering step: Bayer RG 8 output has to be converted in software, which adds processing load to the vision PC.
Match the lens to the 1 inch format and 2.4 μm pixels: the image circle and resolving power must suit both.
Specifications: General
Brand
iRAYPLE
Camera type
Area Scan
Specifications: Sensor
Sensor model
GMAX2424
Sensor manufacturer
Gpixel
Sensor size
1"CMOS
Shutter
Rolling/GlobalResetRealease
Mono / color
Color
Resolution
20 MP
Horizontal resolution
5472 × 3648 px
Pixel size
2.4 μm × 2.4 μm
Specifications: Performance
FPS
19.2 fps @5472 × 3648 Bayer RG 8
Specifications: Interface
Interface
USB 3.0
Specifications: Optics
Mount
C-mount
Specifications: Electrical
Supply voltage
Power supply via USB connector /DC power supply by Hirose connector, with voltage range from 9V to 24V
Power consumption
3.3 W
Specifications: Environment
Operating temperature
-30℃~+50℃
Specifications: Mechanical
Dimensions
29 mm×29 mm×30 mm (not including lens mount and rear case connector)
Weight
85 g
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
9 frame grabbers / interface cards are compatible with this camera.
Matched automatically by: card supports the camera interface (usb3 vision) · card link speed is at least the camera link speed (cxp-6 / cxp-12, 1–10 gige) — this camera: USB 3.0.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
Up to 19.2 fps at 5472 × 3648 px in Bayer RG 8.
Yes. It is a color camera with Bayer RG 8 output.
Its shutter is listed as Rolling/GlobalResetRealease.
USB 3.0, powered through the USB connector or a DC supply of 9 V to 24 V via a Hirose connector. Draw is 3.3 W.