The iRAYPLE AH5169CU000E is a colour high-speed area-scan camera with an HR sensor in a 1/2.9 format, giving 1.6 MP at 1440 × 1080 px and a Global shutter. The listed rate is up to 249 fps at 1440 × 1080 Bayer RG 8. A Global shutter exposes all pixels together, so fast-moving objects are captured without rolling skew, and the high frame rate gives many captures per object as it passes. At 1.6 MP the resolution is modest, so this model suits capturing small fields at speed rather than wide fields that need fine detail.
The camera uses USB 3.0 and can be powered from the USB connector or from a DC supply of 9–24 V through a Hirose connector, drawing 2.6 W. Its C-mount accepts standard C-mount lenses. The body measures 29 mm × 29 mm × 30 mm (not including the lens mount and rear connector) and weighs 85 g, which suits compact high-speed stations. The rated operating range is -30 °C to +50 °C.
Capture at this speed depends on light: short, bright pulses are typically needed to freeze motion, so exposure timing should be planned with the lighting. The 249 fps figure is quoted at 1440 × 1080 Bayer RG 8, so keep the field of view and pixel format fixed when sizing the cycle.
Best for
High-speed capture of fast-moving parts on a pick, sort or conveyor line
Colour capture of small fields at high frame rates, where 1440 × 1080 px is sufficient
Global-shutter imaging of moving objects without rolling skew
Compact high-speed cameras for tight machine enclosures
Selection notes
Frame rate: 249 fps is quoted at 1440 × 1080 Bayer RG 8. Keep frame size and pixel format fixed when sizing the cycle.
Lighting and I/O: short, bright pulses suit this speed. Check the trigger and strobe I/O in the manufacturer datasheet before designing the lighting control.
Resolution: 1.6 MP in a 1/2.9 format. For a wider field or finer detail, a sensor with more pixels would be needed.
Host and power: USB 3.0 link, with 2.6 W drawn via USB or from 9–24 V DC via Hirose.
Specifications: General
Brand
iRAYPLE
Camera type
Area Scan
Specifications: Sensor
Sensor model
HR
Sensor size
1/2.9
Shutter
Global
Mono / color
Color
Resolution
1.6 MP
Horizontal resolution
1440 × 1080 px
Pixel size
3.45 μm × 3.45 μm
Specifications: Performance
FPS
249 fps @1440 × 1080 Bayer RG 8
Specifications: Interface
Interface
USB 3.0
Specifications: Optics
Mount
C-mount
Specifications: Electrical
Supply voltage
Power supply via USB connector /DC power supply by Hirose connector, with voltage range from 9V to 24V
Power consumption
2.6 W
Specifications: Environment
Operating temperature
-30℃~+50℃
Specifications: Mechanical
Dimensions
29 mm×29 mm×30 mm (not including lens mount and rear case connector)
Weight
85 g
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
9 frame grabbers / interface cards are compatible with this camera.
Matched automatically by: card supports the camera interface (usb3 vision) · card link speed is at least the camera link speed (cxp-6 / cxp-12, 1–10 gige) — this camera: USB 3.0.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
It is listed at up to 249 fps at 1440 × 1080 px in Bayer RG 8.
Yes. Its quoted output format is Bayer RG 8.
It uses a Global shutter.
It uses USB 3.0 and draws 2.6 W from the USB connector or from a DC 9–24 V supply through a Hirose connector.