The iRAYPLE AH7900CU200E is a color 9.0 MP area scan camera with an IMX267 sensor (listed sensor size of 1), a global shutter and a 4,096 x 2,160 pixel frame with 3.45 µm pixels. The rating is 41.6 fps at 4,096 x 2,160 in Bayer RG 8 output. The global shutter keeps moving parts free of rolling skew across the whole frame, so the model suits color inspection of full-frame images on moving product.
The interface is USB 3.0, so the camera connects to a USB 3.0 port on the host PC rather than a GigE network port. Power can come from the USB connector or from a DC supply of 9 V to 24 V on the Hirose connector, and the listed draw is 3.85 W. Bayer RG 8 is a raw mosaic format, so RGB images require debayering in host software. The C-mount flange accepts standard C-mount lenses, and the listed sensor size of 1 sets the image circle the lens must cover.
The housing is 29 x 44 x 58 mm (not including lens mount and rear case connector) and weighs 140 g, so mounting space should be checked. The listed operating temperature range is -30 to +50 °C. At 41.6 fps and 9.0 MP, the USB 3.0 link and the host need enough throughput to keep up with the full-frame stream.
Best for
Color inspection of full 9.0 MP frames on a PC-based vision system with a USB 3.0 port.
Fast-moving color parts where the global shutter and 41.6 fps at full frame support capture of the complete image.
Installations that use USB 3.0 cabling to a host PC rather than a GigE network.
Installations that need the -30 to +50 °C operating range.
Selection notes
Confirm the host has USB 3.0 and enough throughput for 41.6 fps at 4,096 x 2,160. The full-frame stream is demanding on the link and the PC.
Plan debayering of the Bayer RG 8 output in software if you need RGB images.
Pair a C-mount lens that covers the listed sensor size of 1 with the 3.45 µm pixels, and set the focal length for your field of view.
Use the 3.85 W draw in the power design. The two listed options are the USB connector or 9 V to 24 V DC on the Hirose connector.
Allow for the 29 x 44 x 58 mm body and 140 g in mounting and cable routing.
Specifications: General
Brand
iRAYPLE
Camera type
Area Scan
Specifications: Sensor
Sensor model
IMX267
Sensor manufacturer
Sony
Sensor size
1
Shutter
Global
Mono / color
Color
Resolution
9.0 MP
Horizontal resolution
4096 × 2160 px
Pixel size
3.45 μm × 3.45 μm
Specifications: Performance
FPS
41.6 fps @4096 × 2160 Bayer RG 8
Specifications: Interface
Interface
USB 3.0
Specifications: Optics
Mount
C-mount
Specifications: Electrical
Supply voltage
Power supply via USB connector /DC power supply by Hirose connector, with voltage range from 9V to 24V
Power consumption
3.85 W
Specifications: Environment
Operating temperature
-30℃~+50℃
Specifications: Mechanical
Dimensions
29 mm×44 mm×58 mm (not including lens mount and rear case connector)
Weight
140 g
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
9 frame grabbers / interface cards are compatible with this camera.
Matched automatically by: card supports the camera interface (usb3 vision) · card link speed is at least the camera link speed (cxp-6 / cxp-12, 1–10 gige) — this camera: USB 3.0.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
USB 3.0. It connects to a USB 3.0 port on the host PC.
41.6 fps at 4,096 x 2,160 in Bayer RG 8 output.
Color. The sensor is an IMX267 at 9.0 MP with a global shutter.
Through the USB connector, or with DC 9 V to 24 V on the Hirose connector. Power consumption is 3.85 W.
The listed operating temperature range is -30 to +50 °C.