The MidOpt DF075 is an acrylic diffuser filter with a listed total light transmission of 75% and a thickness of 1mm. Its useful range is 400-1100nm, extending from the visible spectrum into the near-infrared. As the manufacturer puts it, diffusers can be thought of as protective windows for lighting, and this one diffuses and scatters light from a point source such as an LED, lamp filament or laser diode. In practice the DF075 sits in front of that source, shielding the emitter while spreading its output.
At 75% transmission, the remainder of the light reaching the diffuser is not passed through. That loss should be built into the exposure time or LED drive level before the camera settings are chosen, so that the image brightness is set from the light that actually reaches the scene. Because the sheet is only 1mm thick, the mechanical design carries much of the optical result: the holder has to keep the diffuser flat and at a repeatable distance from the source so the light distribution on the scene stays consistent from build to build.
The DF075 is listed as available as unmounted/custom sizes, so the piece can be sized to a specific housing. Its listed color temperature is 6750 K. When specifying the part, treat the transmission, the 400-1100nm useful range and the 1mm thickness as the three figures that define how it behaves in the optical path.
Best for
Scattering the light from a point-source LED before it illuminates the scene.
Front protection for an illumination module that also needs diffused output, in line with the protective-window role described for diffusers.
Laser diode illumination that needs its output spread before reaching the sample, within the 400-1100nm range.
Custom-sized lighting housings where the diffuser must match a particular aperture.
Setups that can absorb the light lost to the diffuser at 75% transmission.
Selection notes
Include the untransmitted share of light in the exposure or LED drive calculation so the camera sees the brightness the design intends.
Check the emitter's wavelength against the 400-1100nm useful range, since that range is the basis for the part's suitability.
Fix the holder so the 1mm sheet sits flat and at a fixed distance from the source, which keeps the light repeatable.
Specify the piece by size, since it is available as unmounted or custom sizes.