The MidOpt LP530 Orange Longpass Filter is part of the MidOpt LP Series, with a listed useful range of 545-1100nm. The manufacturer describes it as blocking UV and blue-green light while passing the longer visible and near-infrared (NIR) wavelengths. The lower edge of the passband sits at 545nm, so the filter is designed to suppress the UV and blue-green content of a scene and pass the remaining visible light from 545nm up to 1100nm. For an installer, that defines the spectral band the camera sees through the filter.
Peak transmission is at least 90% (≥90%) and surface quality is listed as 40/20. The high transmission keeps the passband efficient, but the spectral balance reaching the sensor still shifts once the shorter wavelengths are removed. Plan to re-check exposure and contrast after installation, and confirm that the illumination has a meaningful share of its output above 545nm, since light concentrated at shorter wavelengths will be attenuated. For measurement tasks, verify that the 40/20 surface quality suits the optical requirement.
Mounting follows the same listed options: 27 threaded size options from M13.25–M105, a 25.4® C-Mount format, a slip mount, and unmounted or custom sizes. The threaded range spans from M13.25 to M105, so the lens thread can be matched directly if it falls within that span. Where the housing is non-standard, the slip mount or unmounted or custom option provides the alternative. Mounting should be settled early because it determines how the filter seats relative to the lens.
Best for
Suppressing UV and blue-green background light in the camera path while passing light from 545nm through NIR
Imaging with orange or longer-wavelength illumination where short-wavelength ambient light is a concern
Retrofitting lenses or housings that accept one of the 27 threaded sizes from M13.25–M105
Using a slip-mount or unmounted or custom filter in a bespoke optical stack
Selection notes
Match the mount before the optical layout is fixed: choose from 27 threaded sizes spanning M13.25–M105, or specify the 25.4® C-Mount, slip mount or unmounted/custom format.
Verify that the illumination output lies above 545nm. Sources that emit mainly at blue-green or shorter wavelengths will lose much of their output.
Re-check exposure after installation. Peak transmission is at least 90%, but the spectral balance reaching the sensor changes once the shorter wavelengths are removed.
Confirm that the 40/20 surface quality meets the optical requirement of the application, particularly where the image feeds a measurement.
Specifications: General
Brand
MidOpt
Specifications: Optical
Filter type
Longpass
Filter wavelength
545-1100nm (useful range)
Specifications: Mechanical
Thread / filter size
M13.25–M105 (27 threaded size options)
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Availability
25.4® C-Mount (threads between lens & sensor) / threaded M25.4 Base