The MidOpt LP550 Orange Longpass Filter belongs to the MidOpt LP Series and has a listed useful range of 560-1100nm. The manufacturer says it blocks UV and shorter wavelengths while passing orange, red and near-infrared (NIR) light. Light below the 560nm start of the useful range is meant to be attenuated, and the 560-1100nm band is the one the filter passes. Because orange, red and NIR are the transmitted light named by the manufacturer, the filter suits imaging and illumination whose relevant content sits in that part of the spectrum.
The listed peak transmission is at least 90% (≥90%) and the surface quality is 40/20. A high peak transmission keeps the passband efficient, so the image is shaped mainly by the removal of out-of-band light. The spectral mix reaching the sensor still changes, so exposure, gain and contrast should be checked after installation. Confirm that the 40/20 surface quality meets the optical requirement of the application if the image is used for measurement.
The mount options are 27 threaded size options from M13.25–M105, a 25.4® C-Mount format, a slip mount, and unmounted or custom sizes. Begin with the thread or mount on the lens or housing and pick the matching threaded size from that range. The slip mount and unmounted or custom versions give flexibility where a housing has no standard thread. Settle the mount early, because it defines where the filter sits in the optical path.
Best for
Blocking UV and shorter wavelengths in front of a camera while passing orange, red and NIR light
Imaging with orange, red or NIR illumination where short-wavelength ambient light must be kept out of the image
Fitting existing lenses or housings with one of the 27 threaded sizes from M13.25–M105
Bespoke optical stacks that need an unmounted or custom-sized filter
Selection notes
Choose the mount first. The listed options are 27 threaded sizes from M13.25–M105, plus 25.4® C-Mount, slip mount and unmounted/custom sizes.
Make sure the light source emits within the 560-1100nm useful range. Output concentrated below 560nm will be attenuated.
Plan exposure around the at-least-90% peak transmission. The passband is efficient, but the change in spectral content still affects brightness and contrast, so check after installation.
Check the 40/20 surface quality against the optical needs of the application, particularly where the filter sits in a measurement path.
Specifications: General
Brand
MidOpt
Specifications: Optical
Filter type
Longpass
Filter wavelength
560-1100nm (useful range)
Specifications: Mechanical
Thread / filter size
M13.25–M105 (27 threaded size options)
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Availability
25.4® C-Mount (threads between lens & sensor) / threaded M25.4 Base