The Omron E6B2-C is a compact incremental rotary encoder with a 40 mm diameter housing and a 6 mm solid shaft. Its resolution range is 20–2000 PPR in ten steps: 20, 100, 200, 360, 500, 600, 1000, 1024, 1800 and 2000 PPR. Line driver output models are available.
Output options are NPN, PNP and Line driver (RS-422), and the supply is 4.8-5.2 V / 12-24 V / 5-24 V depending on the variant. The order codes show how these combine: line driver models at 5 VDC, PNP models at 12-24 VDC, and NPN models at 5-24 VDC, some of the latter described as 3-phase. The connection is a cable, with 0.5 m and 2 m lengths in the order codes, so output type, supply, resolution and cable length are chosen through the order code.
In machine-vision systems an incremental encoder's general role is to deliver pulses that follow shaft rotation, so a controller can track conveyor motion or time image capture. A resolution range reaching 2000 PPR, along with an RS-422 line driver option, gives a choice of pulse resolution and signal type for different counting inputs.
Best for
Conveyor and roller feedback needing between 20 and 2000 PPR
Systems with RS-422 line driver, NPN or PNP counter inputs
Axes with a 6 mm shaft where a 40 mm housing fits
Machines supplied at 4.8-5.2 V, 12-24 V or 5-24 V, depending on the variant
Selection notes
Select the output type first (NPN, PNP or Line driver (RS-422)), because the supply range follows from the variant.
Choose the resolution from the ten values; resolution, output and cable length are ordered through separate codes.
The order codes show 0.5 m and 2 m cables; select the length that reaches the controller or terminal.
Check that the supply on the machine matches the variant: 4.8-5.2 V, 12-24 V or 5-24 V.
The shaft is solid and 6 mm in diameter, and the housing is 40 mm; check mounting space and coupling.
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Availability
Encoder, incremental, 1000 ppr, 5 VDC, Line driver 0.5 m cable Base
On request
Encoder, incremental, 1000ppr, 5 VDC, Line driver 2m cable
On request
Encoder, incremental, 1024ppr, 5 VDC, Line driver 0.5m cable
On request
Encoder, incremental, 2000ppr, 5 VDC, Line driver 0.5m cable
On request
Encoder, incremental, 2000ppr, 5 VDC, Line driver 2m cable
On request
Encoder, incremental, 200ppr, 5 VDC, Line driver 0.5m cable
On request
Encoder, incremental, 360 ppr, 5 VDC, Line driver 0.5 m cable
On request
Encoder, incremental, 500ppr, 5 VDC, Line driver 0.5m cable
These steps take an Omron Sentech (STC) camera from the box to a stable first image and on to your own application. They apply across the GigE Vision, USB3 Vision and CoaXPress STC families; the interface only changes how you cable and power the camera.
Download and install the Sentech SDK on the host PC. The package provides StViewer, the viewing and configuration software you use to bring the camera up, and StApi, the programming SDK you integrate later. Because the cameras are GenICam/GenTL-compliant, StApi also registers a GenTL producer, so any GenICam-compliant third-party vision software can discover and drive the camera as an alternative front end.
2. Cable, power and connect the camera
Connect according to the interface. GigE Vision: link to a Gigabit NIC (use PoE or the separate power input) and put the camera and host on the same subnet; for USB3 Vision use a USB 3.x port and a certified cable; for CoaXPress (STC) connect to a CoaXPress frame grabber, which also supplies Power-over-Coax. Then open StViewer and let it enumerate the camera. If a GigE camera does not appear, check the IP configuration and firewall, and on USB3 confirm the host bandwidth and driver.
3. Configure exposure, gain and white balance
Open the device in StViewer and start a live stream. Set exposure and gain for a well-exposed, low-noise image: raise exposure first and only add gain when more light or a faster shutter is not an option, keeping exposure short enough to freeze motion on global-shutter models. On colour cameras, run white balance under your actual production lighting. Adjust the lens aperture and focus on a representative target before tuning anything else.
4. Set the trigger and grab a first image
Start in free-run (continuous) acquisition to confirm a clean, stable image. For inline inspection switch to hardware or software triggering: select the trigger source, set the active edge and any delay, and wire the strobe or illumination to the camera's I/O so lighting fires with each exposure. Acquire and save a frame in StViewer; this saved image is your reference for the SDK stage and for downstream inspection.
5. Move to the StApi SDK (or any GenICam software)
Once the image is stable, reproduce the same settings in code. Use StApi to open the device, apply the GenICam features you validated in StViewer (exposure, gain, trigger, pixel format) and grab frames into your application via the bundled C++, C, C#/.NET or Python interfaces; the included samples are the fastest starting point. Prefer a different stack? The same GenICam/GenTL camera works with third-party vision libraries. With a reliable feed, you can route it into a deep-learning inspection such as Rosepetal for AI-based defect detection.
Frequently asked questions
20–2000 PPR in ten resolutions: 20, 100, 200, 360, 500, 600, 1000, 1024, 1800 and 2000 PPR.
NPN, PNP and Line driver (RS-422).
A solid shaft with a 6 mm diameter in a 40 mm housing.
The supply is 4.8-5.2 V / 12-24 V / 5-24 V depending on the variant, and the connection is a cable.