The Omron E6C2-C / E6C3-C is an incremental rotary encoder family with a 50 mm diameter housing and 6 mm / 8 mm solid shaft options. Resolution covers 10–3600 PPR in 12 values: 10, 60, 100, 200, 360, 500, 600, 1000, 1024, 1500, 2000 and 3600 PPR. The family is described as having improved water resistance, with an IP64f or IP65f drip-proof, oil-proof construction.
The outputs are NPN, Line driver (RS-422), PNP and Push-pull (complementary), and the supply is 4.8-5.2 V / 12-24 V / 5-24 V / 5-12 V depending on the variant. The order codes show line driver models at 5 VDC, PNP models at 12-24 VDC, and NPN models at 5-24 VDC, while the 8 mm shaft rugged-housing models are shown with line driver output at 5-12 VDC or complementary output at 12-24 VDC. Connection is a cable, with 1 m, 2 m and 5 m lengths appearing in the order codes.
For vision systems an incremental encoder's general role is to provide a pulse train that follows rotation, which a controller can count to track conveyor motion or use to time image capture. The drip-proof, oil-proof construction suits locations exposed to drips or oil, and the 10–3600 PPR range provides a choice of pulse resolution per revolution.
Best for
Conveyor or roller feedback in locations where drip-proof, oil-proof construction (IP64f or IP65f) is wanted
Systems needing a choice of NPN, Line driver (RS-422), PNP or Push-pull (complementary) outputs
Axes with a 6 mm or 8 mm solid shaft and room for a 50 mm housing
Applications that need anywhere from 10 to 3600 PPR
Selection notes
Pick the output type first, since the supply range follows from the variant (4.8-5.2 V, 12-24 V, 5-24 V or 5-12 V).
Choose between the 6 mm and the 8 mm shaft; the 8 mm shaft models in the order codes are described as rugged housing versions.
Select the resolution from the 12 values; resolution, output, supply and cable length are ordered through separate codes.
Cable lengths of 1 m, 2 m and 5 m appear in the order codes; choose the one that reaches the controller.
Confirm that the receiving input matches the output type, and check the 50 mm housing against the mounting space.
NPN, Line driver (RS-422), PNP, Push-pull (complementary)
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Availability
Encoder, incremental, 1000ppr, 5 VDC, Line driver output, 2m cable Base
On request
Encoder, incremental, 1000 ppr, 5 VDC, Line driver output, 5 m cable
On request
Encoder, incremental, 1024 ppr, 5 VDC, Line driver output, 2 m cable
On request
Encoder, incremental, 2000ppr, 5 VDC, Line driver output, 2m cable
On request
Encoder, incremental, 500ppr, 5 VDC, Line driver output, 2m cable
These steps take an Omron Sentech (STC) camera from the box to a stable first image and on to your own application. They apply across the GigE Vision, USB3 Vision and CoaXPress STC families; the interface only changes how you cable and power the camera.
Download and install the Sentech SDK on the host PC. The package provides StViewer, the viewing and configuration software you use to bring the camera up, and StApi, the programming SDK you integrate later. Because the cameras are GenICam/GenTL-compliant, StApi also registers a GenTL producer, so any GenICam-compliant third-party vision software can discover and drive the camera as an alternative front end.
2. Cable, power and connect the camera
Connect according to the interface. GigE Vision: link to a Gigabit NIC (use PoE or the separate power input) and put the camera and host on the same subnet; for USB3 Vision use a USB 3.x port and a certified cable; for CoaXPress (STC) connect to a CoaXPress frame grabber, which also supplies Power-over-Coax. Then open StViewer and let it enumerate the camera. If a GigE camera does not appear, check the IP configuration and firewall, and on USB3 confirm the host bandwidth and driver.
3. Configure exposure, gain and white balance
Open the device in StViewer and start a live stream. Set exposure and gain for a well-exposed, low-noise image: raise exposure first and only add gain when more light or a faster shutter is not an option, keeping exposure short enough to freeze motion on global-shutter models. On colour cameras, run white balance under your actual production lighting. Adjust the lens aperture and focus on a representative target before tuning anything else.
4. Set the trigger and grab a first image
Start in free-run (continuous) acquisition to confirm a clean, stable image. For inline inspection switch to hardware or software triggering: select the trigger source, set the active edge and any delay, and wire the strobe or illumination to the camera's I/O so lighting fires with each exposure. Acquire and save a frame in StViewer; this saved image is your reference for the SDK stage and for downstream inspection.
5. Move to the StApi SDK (or any GenICam software)
Once the image is stable, reproduce the same settings in code. Use StApi to open the device, apply the GenICam features you validated in StViewer (exposure, gain, trigger, pixel format) and grab frames into your application via the bundled C++, C, C#/.NET or Python interfaces; the included samples are the fastest starting point. Prefer a different stack? The same GenICam/GenTL camera works with third-party vision libraries. With a reliable feed, you can route it into a deep-learning inspection such as Rosepetal for AI-based defect detection.
Frequently asked questions
10–3600 PPR in 12 resolutions: 10, 60, 100, 200, 360, 500, 600, 1000, 1024, 1500, 2000 and 3600 PPR.
The solid shaft is 6 mm / 8 mm in diameter, in a 50 mm housing.
NPN, Line driver (RS-422), PNP and Push-pull (complementary).
It is described as having improved water resistance, with an IP64f or IP65f drip-proof, oil-proof construction.
Through a cable. The order codes show 1 m, 2 m and 5 m cable lengths.