Eight ports on 8 cores give twice the cores of the FH-5551-20, which spreads 4 cores over the same 8 ports. RAM is 32 GB (non-ECC). Real headroom still depends on the tools, the image size and how many cameras trigger together. This is the extended-storage version, so confirm the drive capacity if you plan to archive images from eight cameras.
Omron labels it FH next generation, with EtherNet/IP, PROFINET and EtherCAT, AI Fine Matching and the AI scratch-detection filter. For line-scan work, Omron's series statement allows up to four Omron Sentech GigE line-scan cameras, so a mixed design on the eight ports has to stay within that count.
Best for
Large multi-station machines where eight cameras each run a full program and several fire together, such as a rotary inspection table with one camera per position.
Combined AI and conventional inspection: AI filters on the critical views and rule-based tools on the rest, all on one controller.
Lines with an EtherCAT master, where all camera results must return on the same network.
Selection notes
Check the cycle time on real parts: eight views with AI filters is a heavy load. AIS Vision can run application validation with your sample parts before you commit.
If only 4 cameras are needed, FH-5552-10 has the same 8 cores and the extra ports here would stay unused.
The FH-UMAI1 USB licence dongle is an accessory; add it to the order if AI is in scope.
Specifications: General
Brand
Omron
AI / deep learning
Yes — AI Fine Matching + AI scratch-detection filter
Specifications: Performance
On-board processing
Intel Core i7 (8-core) — Omron performance class "Very high"
On-board memory
32 GB RAM (non ECC)
Specifications: Interface
Camera ports
8 cameras
Communication
Ethernet, EtherNet/IP, PROFINET, EtherCAT, RS-232, USB, digital I/O (PNP/NPN)
Trigger / GPIO
Parallel I/O, PNP/NPN outputs (parallel I/O cables listed as accessories)
Specifications: Electrical
Supply voltage
24 V DC (Omron category filter)
Specifications: Software
Operating systems
Windows 10 IoT Enterprise 2019 LTSC - 64 bit
Software / API
FH vision software; Open FH runs vision algorithms developed in MVTec HALCON HDevelop (FH-series feature)
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Availability
FH Next generation high-speed / high performance / extended storage, controller 8-core, NPN/PNP, 8 cameras, W10 IoT Enterprise LTSC 2019 64bit Base
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
These steps take an Omron Sentech (STC) camera from the box to a stable first image and on to your own application. They apply across the GigE Vision, USB3 Vision and CoaXPress STC families; the interface only changes how you cable and power the camera.
Download and install the Sentech SDK on the host PC. The package provides StViewer, the viewing and configuration software you use to bring the camera up, and StApi, the programming SDK you integrate later. Because the cameras are GenICam/GenTL-compliant, StApi also registers a GenTL producer, so any GenICam-compliant third-party vision software can discover and drive the camera as an alternative front end.
2. Cable, power and connect the camera
Connect according to the interface. GigE Vision: link to a Gigabit NIC (use PoE or the separate power input) and put the camera and host on the same subnet; for USB3 Vision use a USB 3.x port and a certified cable; for CoaXPress (STC) connect to a CoaXPress frame grabber, which also supplies Power-over-Coax. Then open StViewer and let it enumerate the camera. If a GigE camera does not appear, check the IP configuration and firewall, and on USB3 confirm the host bandwidth and driver.
3. Configure exposure, gain and white balance
Open the device in StViewer and start a live stream. Set exposure and gain for a well-exposed, low-noise image: raise exposure first and only add gain when more light or a faster shutter is not an option, keeping exposure short enough to freeze motion on global-shutter models. On colour cameras, run white balance under your actual production lighting. Adjust the lens aperture and focus on a representative target before tuning anything else.
4. Set the trigger and grab a first image
Start in free-run (continuous) acquisition to confirm a clean, stable image. For inline inspection switch to hardware or software triggering: select the trigger source, set the active edge and any delay, and wire the strobe or illumination to the camera's I/O so lighting fires with each exposure. Acquire and save a frame in StViewer; this saved image is your reference for the SDK stage and for downstream inspection.
5. Move to the StApi SDK (or any GenICam software)
Once the image is stable, reproduce the same settings in code. Use StApi to open the device, apply the GenICam features you validated in StViewer (exposure, gain, trigger, pixel format) and grab frames into your application via the bundled C++, C, C#/.NET or Python interfaces; the included samples are the fastest starting point. Prefer a different stack? The same GenICam/GenTL camera works with third-party vision libraries. With a reliable feed, you can route it into a deep-learning inspection such as Rosepetal for AI-based defect detection.
Frequently asked questions
It has 8 camera ports and 8 cores. Whether the full cycle fits depends on the tools and image sizes, so confirm it on sample parts.
No, there is no integrated monitor. Connect a display for set-up; the controller is powered from 24 V DC.