Collimated illuminators that pair with telecentric lenses for high-contrast backlit gauging, with sharp edges and efficient light coupling.
A telecentric illuminator is a collimated backlight. Instead of scattering light in all directions as a diffuse panel does, it sends a near-parallel beam along the optical axis, designed to feed a telecentric lens. Because that lens accepts only rays close to parallel with its axis, most of the light is put to use, and the image is bright with a sharply defined part edge.
Its job is narrow: backlit gauging, particularly of parts with rounded or reflective sides, where diffuse backlights produce edge errors. This category comes from Opto Engineering. Selection is less a comparison of brightness than a matching exercise against the lens you have already specified. AIS Vision validates telecentric measurement setups on real parts, lens and illuminator together.
Opto Engineering LTCL4K060-G — Telecentric illuminator for line scan cameras, beam dimension 71 x 10 mm, green, 525 nm (LTCL4K series: Flat telecentric illuminators for line scan cameras).
Telecentric (Telecentric lights)
Green, 525 nm
71 × 10 mm (minimum beam shape dimension; beam shape is not circular)
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Opto Engineering LTCL4K060-W — Telecentric illuminator for line scan cameras, beam dimension 71 x 10 mm, white, 6000 K (LTCL4K series: Flat telecentric illuminators for line scan cameras).
Telecentric (Telecentric lights)
White, 6000 K
71 × 10 mm (minimum beam shape dimension; beam shape is not circular)
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Opto Engineering LTCL4K090-G — Telecentric illuminator for line scan cameras, beam dimension 102 x 10 mm, green, 525 nm (LTCL4K series: Flat telecentric illuminators for line scan cameras).
Telecentric (Telecentric lights)
Green, 525 nm
102 × 10 mm (minimum beam shape dimension; beam shape is not circular)
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Opto Engineering LTCL4K090-W — Telecentric illuminator for line scan cameras, beam dimension 102 x 10 mm, white, 6000 K (LTCL4K series: Flat telecentric illuminators for line scan cameras).
Telecentric (Telecentric lights)
White, 6000 K
102 × 10 mm (minimum beam shape dimension; beam shape is not circular)
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Opto Engineering LTCL4K120-G — Telecentric illuminator for line scan cameras, beam dimension 132 x 10 mm, green, 525 nm (LTCL4K series: Flat telecentric illuminators for line scan cameras).
Telecentric (Telecentric lights)
Green, 525 nm
132 × 10 mm (minimum beam shape dimension; beam shape is not circular)
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Opto Engineering LTCL4K120-W — Telecentric illuminator for line scan cameras, beam dimension 132 x 10 mm, white, 6000 K (LTCL4K series: Flat telecentric illuminators for line scan cameras).
Telecentric (Telecentric lights)
White, 6000 K
132 × 10 mm (minimum beam shape dimension; beam shape is not circular)
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Opto Engineering LTCL4K180-G — Telecentric illuminator for line scan cameras, beam dimension 187 x 10 mm, green, 525 nm (LTCL4K series: Flat telecentric illuminators for line scan cameras).
Telecentric (Telecentric lights)
Green, 525 nm
187 × 10 mm (minimum beam shape dimension; beam shape is not circular)
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Opto Engineering LTCL4K180-W — Telecentric illuminator for line scan cameras, beam dimension 187 x 10 mm, white, 6000 K (LTCL4K series: Flat telecentric illuminators for line scan cameras).
Telecentric (Telecentric lights)
White, 6000 K
187 × 10 mm (minimum beam shape dimension; beam shape is not circular)
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Opto Engineering LTCLCP144-G — Space-saving telecentric illuminator for LARGE FOV systems, minimun beam shape dimension 165 x 120 mm, green (LTCLHP CORE PLUS series: Compact telecentric illuminators for large FOV systems).
Telecentric (Telecentric lights)
Green, 525 nm
165 × 120 mm (minimum beam shape dimension; beam shape is not circular)
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Opto Engineering LTCLCP192-G — Space-saving telecentric illuminator for LARGE FOV systems, minimun beam shape dimension 220 x 160 mm, green (LTCLHP CORE PLUS series: Compact telecentric illuminators for large FOV systems).
Telecentric (Telecentric lights)
Green, 525 nm
220 × 160 mm (minimum beam shape dimension; beam shape is not circular)
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Opto Engineering LTCLCP260-G — Space-saving telecentric illuminator for LARGE FOV systems, minimun beam shape dimension 265 x 200 mm, green (LTCLHP CORE PLUS series: Compact telecentric illuminators for large FOV systems).
Telecentric (Telecentric lights)
Green, 525 nm
265 × 200 mm (minimum beam shape dimension; beam shape is not circular)
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
With a diffuse backlight, oblique rays can strike the side wall of a cylindrical or shiny part, reflect and enter the lens. That brightens the boundary and shifts the apparent edge, so the measured value depends on the part's surface finish. A collimated beam contains few such rays, so edge position stays more consistent across materials and finishes. Efficient coupling also permits shorter exposures than a diffuse panel needs for the same image brightness, which helps when parts are measured on the move.
Matching it to your lens
Treat the lens and illuminator as a pair, chosen together from the required field of view.
Illuminated area: the beam must cover the lens's object-side field of view; a smaller one leaves dark corners.
Working distance: position the illuminator within its stated range, leaving space for part handling.
Color / wavelength: use a wavelength the lens is well corrected for. Shorter wavelengths also tighten diffraction at the edge.
Mode, supply voltage and connection: check continuous or pulsed operation and how it will be driven from your system.
Alignment is part of the spec
Lens and illuminator both have narrow angular acceptance, so a small tilt between them shows up as uneven brightness or a darkened region. Mount them on one rigid base with fine adjustment for tilt and shift, then lock it. Vibration or thermal movement in the frame can degrade the match over time, so include the brightness profile in routine checks.
Frequently asked questions
Not always. A diffuse backlight works with a telecentric lens and is more tolerant of alignment, which is fine for flat parts or moderate tolerances. Choose collimated light when part geometry or a tight tolerance makes edge effects visible in your repeatability figures.
It rarely makes sense. A conventional lens accepts rays over a range of angles, so a collimated beam does not fill its view evenly and you tend to see a bright patch rather than a uniform background. Use a diffuse backlight with those lenses.
Start from the lens datasheet and the sensor's response. Shorter visible wavelengths give a tighter diffraction edge, which favours accuracy on fine features, and a monochromatic source avoids chromatic blur.