Skip to content
Opto Engineering LTCLCR080-R machine vision lighting
  • Rosepetal compatible
  • Recommended by AIS Vision

Opto Engineering LTCLCR080-R (LTCLHP CORE series)

LTCLCR080-R

Opto Engineering LTCLCR080-R telecentric illuminator — Red, 625 nm, beam Ø = 98, x = 90 mm, WD 150–300 mm, 12-24 V, 2.5 W max, pulse current up to 2000 mA, M8 connector, A 118.9 mm, B 145.0 mm, C 158.4 mm (A/B/C), 2933 g.

Brand
Opto Engineering
Lighting type
Telecentric (Telecentric lights)
Color / wavelength
Red, 625 nm
Available wavelengths
Red, 625 nm
Working distance
150–300 mm
Illuminated area
Ø = 98, x = 90 mm (minimum beam shape dimension; beam shape is not circular)
Supply voltage
12-24 V (tolerance ± 10%)
Power consumption
2.5 W max
Mode
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Connection
M8
Dimensions
A 118.9 mm, B 145.0 mm, C 158.4 mm (dimensions A/B/C as on the maker’s drawing) — nominal value, with no spacers in place
Weight
2933 g

Technical overview

The LTCLCR080-R is a red telecentric illuminator from Opto Engineering's LTCLHP CORE series of compact telecentric illuminators. It emits at 625 nm, which is red light, and it is listed as a telecentric light, so its role is collimated lighting, with rays that run close to parallel across the working distance rather than spreading from a point. That keeps the light direction and edge definition more consistent as the part moves within the working range, which is why telecentric lighting suits dimensional measurement. Red light at 625 nm suits targets whose contrast is better in that band, a point to confirm on sample parts.

The working distance is listed as 150–300 mm, which defines the band of part-to-illuminator spacing the light is specified for. The illuminated area is listed as Ø = 98, x = 90 mm, given as the minimum beam shape dimension; because the beam is not circular, plan the field of view against both listed dimensions rather than a single round spot. The body measures A 118.9 mm, B 145.0 mm and C 158.4 mm, nominal values from the maker's drawing with no spacers in place, and it weighs 2933 g, which sets the mounting envelope and the load the bracket must carry.

Electrically the unit runs from a 12–24 V supply with ±10% tolerance and draws 2.5 W at most. Continuous and pulsed operation are both listed, with a maximum continuous LED current of 350 mA and a pulse current of up to 2000 mA. Steady-on use should be designed against the continuous limit, and strobed use against the pulse rating. The M8 connector and the 0–40 °C operating range complete the installation details.

Best for

  • Dimensional gauging and edge measurement of parts held 150–300 mm from the illuminator
  • Red-light inspection at 625 nm where the target's contrast is better at a longer visible wavelength
  • Pulsed (strobed) illumination using a pulse current of up to 2000 mA
  • Fixed inspection stations with repeatable geometry in a 0–40 °C environment

Selection notes

  • Hold the part-to-illuminator spacing inside 150–300 mm, the working distance range for this model.
  • Plan the field of view against the Ø = 98, x = 90 mm illuminated area, and remember the beam is not circular.
  • Keep steady-on drive within the 350 mA maximum continuous LED current, and reserve the pulse current of up to 2000 mA for pulsed operation.
  • Allow for the A 118.9 mm, B 145.0 mm and C 158.4 mm envelope and the 2933 g mass; the dimensions are nominal with no spacers in place.
  • Check the trigger and I-O wiring in the manufacturer datasheet before committing to pulsed operation.

Specifications: General
BrandOpto Engineering
Lighting typeTelecentric (Telecentric lights)

Specifications: Interface
ConnectionM8

Specifications: Optical
Color / wavelengthRed, 625 nm
Available wavelengthsRed, 625 nm
Working distance150–300 mm

Specifications: Electrical
Supply voltage12-24 V (tolerance ± 10%)
Power consumption2.5 W max
ModeContinuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)

Specifications: Environment
Operating temperature0–40 °C

Specifications: Geometry
Illuminated areaØ = 98, x = 90 mm (minimum beam shape dimension; beam shape is not circular)

Specifications: Mechanical
DimensionsA 118.9 mm, B 145.0 mm, C 158.4 mm (dimensions A/B/C as on the maker’s drawing) — nominal value, with no spacers in place
Weight2933 g

Frequently asked questions

Related technical guides

Often used with

Lighting controllers

Strobe and intensity control for stable, repeatable illumination.

All lighting controllers →
  • DCM Sistemes VST11I machine vision lighting
    • Strobe (stroboscopic) drive mode
    • This is the controller itself (drives external strobe lighting)
    • 24 VDC
    • Terminal block
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Omron / Sentech FLV-TCC3HB machine vision lighting
    • Trigger (strobe) and continuous lighting
    • IP20 (IEC 60529)
    • Drive: 0ch constant-current, 1ch/2ch constant-voltage; PWM duty 100 kHz / voltage adjustment, 255 levels
    • Up to 15 W (24 V external trigger lighting; 12 V continuous up to 7.5 W)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Basler Light Controller 2C-1.25A-50W-24V machine vision lighting
    • Current-controlled
    • 100–240 VAC input / 8–24 VDC output
    • 50 W (total output)
    • 0–40 °C
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • DCM Sistemes VSC3100B machine vision lighting
    • RGB (drives RGB / mixed colour lighting via 3 channels)
    • Strobe (stroboscopic) drive mode, per-shot current regulation
    • This is the controller itself (drives external strobe/RGB lighting)
    • +24 VDC ±3%
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Lighting cables

Industrial Lighting cables with locking connectors. Check length and flex rating against your installation.

All cables →
  • Opto Engineering LTCLCR048-R machine vision lighting
    • Telecentric (Telecentric lights)
    • Red, 625 nm
    • Ø = 56, x = 50 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Opto Engineering LTCLCR056-R machine vision lighting
    • Telecentric (Telecentric lights)
    • Red, 625 nm
    • Ø = 74, x = 66 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Opto Engineering LTCLCR064-R machine vision lighting
    • Telecentric (Telecentric lights)
    • Red, 625 nm
    • Ø = 86, x = 67 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Rosepetal · AI

Test this camera with Rosepetal

Validate your visual inspection with AI: send us sample images and we evaluate the case on your hardware.

AIS Vision · Integration

We validate camera + lens + lighting

AIS Vision defines and tests the optimal combination of camera, optics and lighting for your application before you buy.