LTCLCR048-G

Opto Engineering LTCLCR048-G telecentric illuminator — Green, 525 nm, beam Ø = 56, x = 50 mm, WD 90–180 mm, 12-24 V, 2.5 W max, pulse current up to 2000 mA, M8 connector, A 76.9 mm, B 106.0 mm, C 117.1 mm (A/B/C), 1030 g.

Brand
Opto Engineering
Lighting type
Telecentric (Telecentric lights)
Color / wavelength
Green, 525 nm
Available wavelengths
Green, 525 nm
Working distance
90–180 mm
Illuminated area
Ø = 56, x = 50 mm (minimum beam shape dimension; beam shape is not circular)
Supply voltage
12-24 V (tolerance ± 10%)
Power consumption
2.5 W max
Mode
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Connection
M8
Dimensions
A 76.9 mm, B 106.0 mm, C 117.1 mm (dimensions A/B/C as on the maker’s drawing) — nominal value, with no spacers in place
Weight
1030 g

Technical overview

The LTCLCR048-G is a telecentric CORE illuminator from the LTCLHP CORE series, which the maker describes as compact telecentric illuminators. It emits green light at 525 nm, and its beam dimensions are listed as Ø = 56, x = 50 mm, given as the minimum beam shape dimension, with the beam shape not circular. The listed working distance is 90–180 mm. Because the output is telecentric and largely collimated, the illumination geometry stays consistent through that range rather than changing with distance.

Electrically the unit is rated at 12-24 V (tolerance ± 10%) with a 2.5 W max draw. Light mode is continuous or pulsed: continuous operation is limited to a maximum LED current of 350 mA, and pulsed operation allows a pulse current of up to 2000 mA. The M8 connector provides the cable interface, and the listed 0–40 °C operating temperature sets the ambient limit. For a compact station, continuous mode gives steady light for stationary parts, while pulsed mode supplies higher peak output for exposures timed to part motion.

Mechanically the unit is specified with drawing dimensions A 76.9 mm, B 106.0 mm and C 117.1 mm, shown on the maker's drawing as nominal values with no spacers in place. It weighs 1030 g, a mass that suits a compact bracket, but the mount still has to hold the working distance steady. Specify the lens together with the light, since a telecentric lens that views this collimated output lets measured positions follow the part geometry rather than lens perspective.

Best for

  • Telecentric measurement of parts that fit within the Ø = 56, x = 50 mm beam, using green 525 nm light.
  • Compact telecentric measurement across a 90–180 mm working distance.
  • Compact stations that need a telecentric light weighing 1030 g.
  • Pulsed exposures on moving parts, with pulse currents up to 2000 mA.
  • OEM integration of a 12-24 V, M8-connected telecentric light in a 0–40 °C environment.

Selection notes

  • Keep the part within the 90–180 mm working distance listed for this model.
  • Stay at or below 350 mA continuous LED current, and use pulsed mode for peak current up to 2000 mA.
  • Size the supply for 12-24 V (tolerance ± 10%) and the 2.5 W maximum draw.
  • Plan the bracket around the A 76.9 mm, B 106.0 mm and C 117.1 mm drawing dimensions and the 1030 g mass, with no spacers in place.
  • Check the M8 pin assignments and any trigger or I/O details in the manufacturer datasheet before wiring pulsed operation.

Specifications: General
BrandOpto Engineering
Lighting typeTelecentric (Telecentric lights)

Specifications: Interface
ConnectionM8

Specifications: Optical
Color / wavelengthGreen, 525 nm
Available wavelengthsGreen, 525 nm
Working distance90–180 mm

Specifications: Electrical
Supply voltage12-24 V (tolerance ± 10%)
Power consumption2.5 W max
ModeContinuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)

Specifications: Environment
Operating temperature0–40 °C

Specifications: Geometry
Illuminated areaØ = 56, x = 50 mm (minimum beam shape dimension; beam shape is not circular)

Specifications: Mechanical
DimensionsA 76.9 mm, B 106.0 mm, C 117.1 mm (dimensions A/B/C as on the maker’s drawing) — nominal value, with no spacers in place
Weight1030 g

Frequently asked questions

Related technical guides

Often used with

Lighting controllers

Strobe and intensity control for stable, repeatable illumination.

All lighting controllers →
  • DCM Sistemes VST11I machine vision lighting
    • Strobe (stroboscopic) drive mode
    • This is the controller itself (drives external strobe lighting)
    • 24 VDC
    • Terminal block
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Omron / Sentech FLV-TCC3HB machine vision lighting
    • Trigger (strobe) and continuous lighting
    • IP20 (IEC 60529)
    • Drive: 0ch constant-current, 1ch/2ch constant-voltage; PWM duty 100 kHz / voltage adjustment, 255 levels
    • Up to 15 W (24 V external trigger lighting; 12 V continuous up to 7.5 W)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Basler Light Controller 2C-1.25A-50W-24V machine vision lighting
    • Current-controlled
    • 100–240 VAC input / 8–24 VDC output
    • 50 W (total output)
    • 0–40 °C
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • DCM Sistemes VSC3100B machine vision lighting
    • RGB (drives RGB / mixed colour lighting via 3 channels)
    • Strobe (stroboscopic) drive mode, per-shot current regulation
    • This is the controller itself (drives external strobe/RGB lighting)
    • +24 VDC ±3%
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Lighting cables

Industrial Lighting cables with locking connectors. Check length and flex rating against your installation.

All cables →
  • Opto Engineering LTCLCR056-G machine vision lighting
    • Telecentric (Telecentric lights)
    • Green, 525 nm
    • Ø = 74, x = 66 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Opto Engineering LTCLCR064-G machine vision lighting
    • Telecentric (Telecentric lights)
    • Green, 525 nm
    • Ø = 86, x = 67 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Opto Engineering LTCLCR080-G machine vision lighting
    • Telecentric (Telecentric lights)
    • Green, 525 nm
    • Ø = 98, x = 90 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Rosepetal · AI

Test this camera with Rosepetal

Validate your visual inspection with AI: send us sample images and we evaluate the case on your hardware.

AIS Vision · Integration

We validate camera + lens + lighting

AIS Vision defines and tests the optimal combination of camera, optics and lighting for your application before you buy.