Skip to content
Opto Engineering LTCLCR048-W machine vision lighting
  • Rosepetal compatible
  • Recommended by AIS Vision

Opto Engineering LTCLCR048-W (LTCLHP CORE series)

LTCLCR048-W

Opto Engineering LTCLCR048-W telecentric illuminator — White, 6000 K, beam Ø = 56, x = 50 mm, WD 90–180 mm, 12-24 V, 2.5 W max, pulse current up to 2000 mA, M8 connector, A 76.9 mm, B 106.0 mm, C 117.1 mm (A/B/C), 1030 g.

Brand
Opto Engineering
Lighting type
Telecentric (Telecentric lights)
Color / wavelength
White, 6000 K
Available wavelengths
White, 6000 K
Color temperature
6000 K
Working distance
90–180 mm
Illuminated area
Ø = 56, x = 50 mm (minimum beam shape dimension; beam shape is not circular)
Supply voltage
12-24 V (tolerance ± 10%)
Power consumption
2.5 W max
Mode
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Connection
M8
Dimensions
A 76.9 mm, B 106.0 mm, C 117.1 mm (dimensions A/B/C as on the maker’s drawing) — nominal value, with no spacers in place

Technical overview

The LTCLCR048-W is a telecentric CORE illuminator from the LTCLHP CORE series, which the maker describes as compact telecentric illuminators. It produces white light at 6000 K, with beam dimensions listed as Ø = 56, x = 50 mm as the minimum beam shape dimension, and the beam shape is not circular. The listed working distance is 90–180 mm. Telecentric output is largely collimated, so the lighting geometry holds through that range, and the 6000 K color temperature gives a cool white source for measurements where white light is preferred.

Electrically the unit is rated at 12-24 V (tolerance ± 10%) with a 2.5 W maximum draw. Light mode is continuous or pulsed, with continuous LED current limited to 350 mA and pulse current up to 2000 mA. The M8 connector provides the cable interface, and the listed 0–40 °C operating temperature sets the environment. Continuous operation keeps the light steady for stationary parts, while pulsed operation provides higher peak output for exposures timed to part motion.

The drawing dimensions are A 76.9 mm, B 106.0 mm and C 117.1 mm, shown on the maker's drawing as nominal values with no spacers in place, and the unit weighs 1030 g. Allow for that envelope and any spacers in the mount design, and keep the working distance repeatable. Specify a telecentric lens with the light, so the camera views the collimated output and the measured edges reflect the part geometry.

Best for

  • Telecentric measurement of parts that fit a Ø = 56, x = 50 mm beam, under cool white 6000 K light.
  • Dimensional gauging across a 90–180 mm working distance.
  • Stations that prefer a white source over a single-color light.
  • Compact stations that need a 1030 g telecentric light.
  • Pulsed illumination for moving parts, using pulse currents up to 2000 mA.

Selection notes

  • Keep the part within the 90–180 mm working distance listed for this model.
  • Limit continuous operation to 350 mA LED current, and use pulsed mode, up to 2000 mA pulse current, for peak output.
  • Power the unit from 12-24 V (tolerance ± 10%), with 2.5 W max.
  • Lay out the mount around the A 76.9 mm, B 106.0 mm and C 117.1 mm drawing dimensions, nominal with no spacers in place.
  • Check the M8 pin assignments and any trigger or I/O details in the manufacturer datasheet before wiring pulsed operation.

Specifications: General
BrandOpto Engineering
Lighting typeTelecentric (Telecentric lights)

Specifications: Interface
ConnectionM8

Specifications: Optical
Color / wavelengthWhite, 6000 K
Available wavelengthsWhite, 6000 K
Color temperature6000 K
Working distance90–180 mm

Specifications: Electrical
Supply voltage12-24 V (tolerance ± 10%)
Power consumption2.5 W max
ModeContinuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)

Specifications: Environment
Operating temperature0–40 °C

Specifications: Geometry
Illuminated areaØ = 56, x = 50 mm (minimum beam shape dimension; beam shape is not circular)

Specifications: Mechanical
DimensionsA 76.9 mm, B 106.0 mm, C 117.1 mm (dimensions A/B/C as on the maker’s drawing) — nominal value, with no spacers in place
Weight1030 g

Frequently asked questions

Related technical guides

Often used with

Lighting controllers

Strobe and intensity control for stable, repeatable illumination.

All lighting controllers →
  • DCM Sistemes VST11I machine vision lighting
    • Strobe (stroboscopic) drive mode
    • This is the controller itself (drives external strobe lighting)
    • 24 VDC
    • Terminal block
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Omron / Sentech FLV-TCC3HB machine vision lighting
    • Trigger (strobe) and continuous lighting
    • IP20 (IEC 60529)
    • Drive: 0ch constant-current, 1ch/2ch constant-voltage; PWM duty 100 kHz / voltage adjustment, 255 levels
    • Up to 15 W (24 V external trigger lighting; 12 V continuous up to 7.5 W)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Basler Light Controller 2C-1.25A-50W-24V machine vision lighting
    • Current-controlled
    • 100–240 VAC input / 8–24 VDC output
    • 50 W (total output)
    • 0–40 °C
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • DCM Sistemes VSC3100B machine vision lighting
    • RGB (drives RGB / mixed colour lighting via 3 channels)
    • Strobe (stroboscopic) drive mode, per-shot current regulation
    • This is the controller itself (drives external strobe/RGB lighting)
    • +24 VDC ±3%
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Lighting cables

Industrial Lighting cables with locking connectors. Check length and flex rating against your installation.

All cables →
  • Opto Engineering LTCLCR056-W machine vision lighting
    • Telecentric (Telecentric lights)
    • White, 6000 K
    • Ø = 74, x = 66 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Opto Engineering LTCLCR064-W machine vision lighting
    • Telecentric (Telecentric lights)
    • White, 6000 K
    • Ø = 86, x = 67 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Opto Engineering LTCLCR080-W machine vision lighting
    • Telecentric (Telecentric lights)
    • White, 6000 K
    • Ø = 98, x = 90 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Rosepetal · AI

Test this camera with Rosepetal

Validate your visual inspection with AI: send us sample images and we evaluate the case on your hardware.

AIS Vision · Integration

We validate camera + lens + lighting

AIS Vision defines and tests the optimal combination of camera, optics and lighting for your application before you buy.