Skip to content
Opto Engineering LTCLCR080-W machine vision lighting
  • Rosepetal compatible
  • Recommended by AIS Vision

Opto Engineering LTCLCR080-W (LTCLHP CORE series)

LTCLCR080-W

Opto Engineering LTCLCR080-W telecentric illuminator — White, 6000 K, beam Ø = 98, x = 90 mm, WD 150–300 mm, 12-24 V, 2.5 W max, pulse current up to 2000 mA, M8 connector, A 118.9 mm, B 145.0 mm, C 158.4 mm (A/B/C), 2934 g.

Brand
Opto Engineering
Lighting type
Telecentric (Telecentric lights)
Color / wavelength
White, 6000 K
Available wavelengths
White, 6000 K
Color temperature
6000 K
Working distance
150–300 mm
Illuminated area
Ø = 98, x = 90 mm (minimum beam shape dimension; beam shape is not circular)
Supply voltage
12-24 V (tolerance ± 10%)
Power consumption
2.5 W max
Mode
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Connection
M8
Dimensions
A 118.9 mm, B 145.0 mm, C 158.4 mm (dimensions A/B/C as on the maker’s drawing) — nominal value, with no spacers in place

Technical overview

The LTCLCR080-W is a white telecentric illuminator with a 6000 K color temperature, part of the LTCLHP CORE series of compact telecentric illuminators. Telecentric illumination emits near-parallel (collimated) light. Paired with a telecentric lens, it helps keep a feature's apparent size and position stable over small changes in distance. The listed working distance of 150–300 mm sets the stand-off band in which the part and lens can be placed, and the listed beam of Ø = 98, x = 90 mm sets the area that is lit. The beam is not circular, and x = 90 mm is the minimum beam-shape dimension, so the feature footprint should be checked against both values rather than the diameter alone.

Electrically, the unit runs from a 12–24 V supply with a ±10% tolerance and draws 2.5 W max. Its light mode is continuous or pulsed. Continuous operation is limited to a maximum LED current of 350 mA, while pulsed operation allows a pulse current of up to 2000 mA, so the controller must be set for the mode in use. The connection is an M8 connector, and the 0–40 °C operating temperature range sets the ambient limit for the installation.

Mechanically, the listed dimensions are A 118.9 mm, B 145.0 mm and C 158.4 mm, as given on the maker's drawing, nominal and with no spacers in place, and the unit weighs 2934 g. That mass calls for a rigid bracket rather than a light clamp, so the mounting envelope should be drawn to those nominal figures. The output is white light at 6000 K, and whether that color gives the contrast the application needs is best confirmed with sample parts before the stand is fixed.

Best for

  • Silhouette and edge gauging of parts placed within the 150–300 mm working distance, paired with a telecentric lens.
  • Position and dimensional checks on small parts that fit inside the Ø = 98, x = 90 mm beam.
  • White-light telecentric inspection where 6000 K white light is the chosen light source.
  • Stations that alternate between continuous and pulsed illumination within the 350 mA continuous and 2000 mA pulse limits.

Selection notes

  • Set the stand-off so the part and lens sit within 150–300 mm, since the working distance is the main constraint on the mechanical layout.
  • Confirm that the non-circular Ø = 98, x = 90 mm beam covers the feature footprint with margin, using x = 90 mm as the minimum beam-shape dimension.
  • Budget a 12–24 V supply with ±10% tolerance for the 2.5 W max draw, and keep continuous LED current at or below 350 mA.
  • Draw the mounting envelope from A 118.9 mm, B 145.0 mm and C 158.4 mm (nominal, no spacers in place) and support the 2934 g mass on a rigid bracket.
  • Confirm in the manufacturer datasheet how pulsed mode is triggered and wired through the M8 connector before finalizing the cabling plan.

Specifications: General
BrandOpto Engineering
Lighting typeTelecentric (Telecentric lights)

Specifications: Interface
ConnectionM8

Specifications: Optical
Color / wavelengthWhite, 6000 K
Available wavelengthsWhite, 6000 K
Color temperature6000 K
Working distance150–300 mm

Specifications: Electrical
Supply voltage12-24 V (tolerance ± 10%)
Power consumption2.5 W max
ModeContinuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)

Specifications: Environment
Operating temperature0–40 °C

Specifications: Geometry
Illuminated areaØ = 98, x = 90 mm (minimum beam shape dimension; beam shape is not circular)

Specifications: Mechanical
DimensionsA 118.9 mm, B 145.0 mm, C 158.4 mm (dimensions A/B/C as on the maker’s drawing) — nominal value, with no spacers in place
Weight2934 g

Frequently asked questions

Related technical guides

Often used with

Lighting controllers

Strobe and intensity control for stable, repeatable illumination.

All lighting controllers →
  • DCM Sistemes VST11I machine vision lighting
    • Strobe (stroboscopic) drive mode
    • This is the controller itself (drives external strobe lighting)
    • 24 VDC
    • Terminal block
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Omron / Sentech FLV-TCC3HB machine vision lighting
    • Trigger (strobe) and continuous lighting
    • IP20 (IEC 60529)
    • Drive: 0ch constant-current, 1ch/2ch constant-voltage; PWM duty 100 kHz / voltage adjustment, 255 levels
    • Up to 15 W (24 V external trigger lighting; 12 V continuous up to 7.5 W)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Basler Light Controller 2C-1.25A-50W-24V machine vision lighting
    • Current-controlled
    • 100–240 VAC input / 8–24 VDC output
    • 50 W (total output)
    • 0–40 °C
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • DCM Sistemes VSC3100B machine vision lighting
    • RGB (drives RGB / mixed colour lighting via 3 channels)
    • Strobe (stroboscopic) drive mode, per-shot current regulation
    • This is the controller itself (drives external strobe/RGB lighting)
    • +24 VDC ±3%
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Lighting cables

Industrial Lighting cables with locking connectors. Check length and flex rating against your installation.

All cables →
  • Opto Engineering LTCLCR048-W machine vision lighting
    • Telecentric (Telecentric lights)
    • White, 6000 K
    • Ø = 56, x = 50 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Opto Engineering LTCLCR056-W machine vision lighting
    • Telecentric (Telecentric lights)
    • White, 6000 K
    • Ø = 74, x = 66 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Opto Engineering LTCLCR064-W machine vision lighting
    • Telecentric (Telecentric lights)
    • White, 6000 K
    • Ø = 86, x = 67 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Rosepetal · AI

Test this camera with Rosepetal

Validate your visual inspection with AI: send us sample images and we evaluate the case on your hardware.

AIS Vision · Integration

We validate camera + lens + lighting

AIS Vision defines and tests the optimal combination of camera, optics and lighting for your application before you buy.