The Basler blaze-112 is a Time of flight (ToF) 3D camera based on the Sony DepthSense™ IMX556 sensor, delivering 0.31 MP (640 × 480 px) in Mono at 30 fps. It supplies its own illumination from 4 x VCSEL laser diodes at 850 nm, class 1, and covers a working range of 0.3 m - 10 m.
A key figure is the 108° x 77° field of view, a wide angle that frames a large area at a given distance. Typical accuracy is ±5 mm (0.5 – 3.5 m). Output data comprises point cloud (XYZ), range map, intensity image and confidence map, so the application receives geometry plus an intensity view and a confidence map. With 640 px spread across such a wide angle and ±5 mm typical accuracy, the data suits scene-level geometry such as presence and position rather than fine detail on small features.
Integration details are a GigE interface, a 24 VDC ±10% supply (<11.5 W mean; <38 W peak), an IP67 housing of 100 mm x 81 mm x 64 mm, a weight of 680 g and an operating temperature of 0 °C - 50 °C.
Best for
Capturing large workspaces or zones, thanks to the 108° x 77° field of view
Scene-level 3D tasks within 0.5 – 3.5 m where the typical ±5 mm accuracy is sufficient
Applications that need point cloud (XYZ), range map, intensity image and confidence map from one GigE device
Installations that require an IP67 housing and a 24 VDC supply with <11.5 W mean and <38 W peak consumption
Selection notes
Typical accuracy of ±5 mm is quoted for 0.5 – 3.5 m, a narrower band than the full 0.3 m - 10 m working range, so place the critical measurement region inside it.
The 108° x 77° field of view spreads the 640 × 480 px over a wide angle; calculate the coverage and pixel density at your working distance before fixing the mounting position.
Power the camera from 24 VDC ±10% and size the supply for the <38 W peak figure.
Allow for the 0 °C - 50 °C operating temperature range when mounting in cabinets or enclosed housings.
Check in the manufacturer datasheet how accuracy behaves beyond 3.5 m if the scene extends toward the 10 m end of the working range.
Specifications: General
Brand
Basler
Camera type
3D camera
Specifications: Sensor
Resolution
0.31 MP (640 × 480 px)
Horizontal resolution
640 px
Mono / color
Mono
Sensor model
Sony DepthSense™ IMX556
Specifications: Performance
FPS
30 fps
Specifications: Interface
Interface
GigE
Specifications: Optical
Field of view
108° x 77°
Specifications: Electrical
Power
24 VDC ±10%; <11.5 W mean; <38 W peak
Supply voltage
24 VDC ±10%; <11.5 W mean; <38 W peak
Specifications: Environment
IP rating
IP67
Operating temperature
0 °C - 50 °C
Specifications: 3D
3D technology
Time of flight (ToF)
Working range
0.3 m - 10 m
Accuracy
±5 mm (0.5 – 3.5 m); typical
Illumination / laser class
4 x VCSEL laser diodes; 850 nm; class 1
3D data output
point cloud (XYZ); range map; intensity image; confidence map
Specifications: Mechanical
Dimensions
100 mm x 81 mm x 64 mm
Weight
680 g
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
30 frame grabbers / interface cards are compatible with this camera.
Matched automatically by: card supports the camera interface (gige vision) · card link speed is at least the camera link speed (cxp-6 / cxp-12, 1–10 gige) — this camera: GigE.
By brand
All 30Hikrobot 15Basler 9iRAYPLE 4Opto Engineering 2
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
It is a Time of flight (ToF) 3D camera with 4 x VCSEL laser diodes at 850 nm, laser class 1, and a Sony DepthSense™ IMX556 sensor.
The field of view is 108° x 77° and the working range is 0.3 m - 10 m.
Accuracy is ±5 mm (0.5 – 3.5 m); typical.
It outputs point cloud (XYZ), range map, intensity image and confidence map at 0.31 MP (640 × 480 px), 30 fps, over GigE.
Supply is 24 VDC ±10% with <11.5 W mean and <38 W peak. The housing is IP67, measures 100 mm x 81 mm x 64 mm and weighs 680 g.