The Datalogic AMT58-H is an absolute multi-turn rotary encoder in the blind hollow-shaft version, with a Ø15 mm shaft/bore and a Ø58 mm housing in metal (aluminium). Being absolute multi-turn, its position value covers both the angle within a revolution and the number of turns. The listed resolution is 25 bit (8192 cpr × 4096 turns) for the SSI, PROFIBUS, CANopen and DeviceNet versions, and 30 bit (65536 cpr × 16384 turns) for the FBUS version.
The interface is chosen when ordering. The seven order codes are: SSI 25 bit with cable, M12 or M23; 25 bit ProfiBus; 25 bit CanBus; 25 bit DeviceNet; and 30 bit fieldbus. The output for SSI is Gray SSI, RS-422, and the fieldbus option is listed as fieldbus via the AMT58-FBUS module. Overall size depends on the interface: Ø58x49 mm (SSI), Ø58x71 mm (PROFIBUS, CANopen, DeviceNet) and Ø58x43 mm (FBUS version), which matters for the available mounting depth.
The supply is 7.5-34 VDC, and the listed connections are a 1.5 m cable, an M12 connector or an M23 connector. In machine vision, encoders in general serve as the position reference for a rotating axis or conveyor drive; this one delivers it to the controller as a digital value over SSI or fieldbus.
Best for
Position feedback on a rotating axis where the encoder fits onto a Ø15 mm shaft (blind hollow-shaft mounting).
Multi-turn positioning where the number of revolutions must be tracked, up to 4096 turns at 25 bit or 16384 turns at 30 bit.
Connecting to SSI controllers or to PROFIBUS, CANopen and DeviceNet networks through the matching order code.
Providing a position reference for conveyor or axis drives in inspection lines, read as a digital value by the controller.
Installations that need a Ø58 mm aluminium-housing encoder with a cable, M12 or M23 connection.
Selection notes
Choose the interface first, because it is set by the order code: SSI 25 bit (cable, M12 or M23), 25 bit ProfiBus, CanBus or DeviceNet, or 30 bit fieldbus.
Make sure the controller can read the word length of the variant: 25 bit (8192 cpr × 4096 turns) or 30 bit (65536 cpr × 16384 turns).
Check the mounting depth against the interface: Ø58x49 mm (SSI), Ø58x71 mm (PROFIBUS, CANopen, DeviceNet) or Ø58x43 mm (FBUS version).
The shaft/bore is Ø15 mm blind hollow, so the drive shaft must match, and the supply must be within 7.5-34 VDC.
For the 30 bit fieldbus version, which uses the AMT58-FBUS module, confirm the supported fieldbus protocols in the manufacturer datasheet.
Specifications: General
Brand
Datalogic
Sensor type
Encoder
Encoder type
Absolute multi-turn
Specifications: Performance
Absolute resolution
25 bit (8192 cpr × 4096 turns) — SSI / PROFIBUS / CANopen / DeviceNet; 30 bit (65536 cpr × 16384 turns) — FBUS version
Ø58x49 mm (SSI) / Ø58x71 mm (PROFIBUS, CANopen, DeviceNet) / Ø58x43 mm (FBUS version)
Housing diameter
Ø58 mm
Housing material
Metal - Aluminium
Specifications: Output
Output type
Gray SSI, RS-422
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Connection ●
Shaft / bore diameter
Absolute resolution ●
Communication ●
Availability
Encoder Absolute multiturn - blind hollow 15 mm -SSI 25 bit - cable Base
1.5 m cable
Ø15 mm
25 bit
SSI
On request
Encoder Absolute multiturn - blind hollow 15 mm -SSI 25 bit - M12
M12 connector
Ø15 mm
25 bit
SSI
On request
Encoder Absolute multiturn - blind hollow 15 mm -SSI 25 bit - M23
M23 connector
Ø15 mm
25 bit
SSI
On request
Encoder Absolute multiturn - blind hollow 15 mm -25 bit - ProfiBus
M12 connector
Ø15 mm
25 bit
PROFIBUS
On request
Encoder Absolute multiturn - blind hollow 15 mm -25 bit - CanBus
M12 connector
Ø15 mm
25 bit
CANopen
On request
Encoder Absolute multiturn - blind hollow 15 mm -25 bit - DeviceNet
M12 connector
Ø15 mm
25 bit
DeviceNet
On request
Encoder Absolute multiturn - blind hollow 15 mm -30 bit - fieldbus
—
Ø15 mm
30 bit
FBUS version
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
1. Install the IMPACT Software Suite and connect the camera
Install the IMPACT Software Suite on your PC, which provides both the configuration/viewer tools and the SDK. For a GigE Vision model (E100, M or U series), connect it to a dedicated NIC and, for USB3 models, use a certified USB3 cable and port. Power the camera and confirm it enumerates.
2. Bring the camera online and verify the link
For GigE Vision, put the camera and the host NIC on the same subnet (a static IP on the camera matching the NIC range is the most reliable starting point); for USB3, confirm the device is recognized. Open the IMPACT viewer/device tool, discover the camera, and verify a stable connection before streaming. Enabling jumbo frames on the NIC helps GigE throughput.
3. Set exposure, gain and trigger, then grab a first image
In the IMPACT tools, start a live stream and adjust exposure and gain until the image is well-lit without saturation; set white balance on color models. Begin in free-run (continuous) mode to confirm imaging, then switch to hardware or software trigger as your application requires. Capture and save a reference image once the scene looks correct.
4. Build a vision tool or move to the SDK/API
Use the IMPACT point-and-click vision tools to assemble an inspection, or use the IMPACT SDK to access the camera and results programmatically and feed them into your HMI/PLC application. As these are GenICam/GenTL-compliant devices, you can alternatively drive them from any GenICam-compliant third-party vision library if your pipeline standardizes on one.
5. Route the stable feed to deep-learning inspection (optional)
Once you have a stable, repeatable image, the feed can be sent to a deep-learning inspection platform such as Rosepetal for defect detection or classification tasks that go beyond rule-based tooling. Keep lighting, optics and trigger timing fixed so the images reaching the model stay consistent.
Frequently asked questions
The SSI, PROFIBUS, CANopen and DeviceNet versions are 25 bit (8192 cpr × 4096 turns); the FBUS version is 30 bit (65536 cpr × 16384 turns).
The listed interfaces are SSI (Gray code, RS-422), PROFIBUS, CANopen, DeviceNet and fieldbus via the AMT58-FBUS module. The output type is Gray SSI, RS-422.
It is a blind hollow shaft with a Ø15 mm bore and a Ø58 mm housing in metal (aluminium).
There are seven order codes: SSI 25 bit with cable, M12 or M23; 25 bit ProfiBus, CanBus and DeviceNet; and 30 bit fieldbus.
The supply is 7.5-34 VDC. The listed connections are a 1.5 m cable, an M12 connector or an M23 connector.