Omron E6F-A absolute rotary encoder — 60 mm housing diameter, 256–360 steps per revolution, 10 mm solid shaft, NPN / PNP output, 5-12 V / 12-24 V supply, cable or system connector connection (model-dependent).
The Omron E6F-A is an absolute rotary encoder with a rugged housing, a 60 mm diameter body and a 10 mm solid shaft. Resolution is 256–360 steps per revolution (256, 360), with BCD / Gray code output over a parallel interface. The shaft is described as stronger and more durable than on previous E6F encoders, at 120 N in the radial direction and 50 N in the thrust direction, and the drip-proof construction meets IP64F standards.
The output is NPN or PNP and the supply is 5-12 V / 12-24 V depending on the variant. The order codes show 360 ppr models with BCD output at 5-12 VDC (2 m cable with an H8PR connector, or a 5 m cable with connector) and 12-24 VDC models with Gray code output at 256 and 360 ppr, supplied on a 2 m cable or with an H8PS connector. The connection is a cable or system connector (model-dependent). A faster response for high-speed control applications is quoted as grey code: 20 kHz.
An absolute encoder reports shaft position as a code value, so the controller reads where the axis is without counting pulses. In vision installations the E6F-A covers the general role of position feedback for a rotary axis, such as a turntable or rotating stage, where image capture or handling steps are tied to the angle. The choice between BCD and Gray code is made through the order code.
Best for
Rotary axes with a 10 mm shaft where the stated shaft strength figures of 120 N radial / 50 N thrust are relevant
Locations needing drip-proof construction to IP64F
Controllers that read parallel BCD or Gray code position values
High-speed control applications where the grey code response of 20 kHz is relevant
Selection notes
Choose between 256 and 360 steps per revolution and between BCD and Gray code output; the order codes show BCD at 5-12 VDC and Gray code at 12-24 VDC.
The output type is NPN or PNP; match it to the controller's parallel inputs.
The connection is a cable or system connector depending on the model; the order codes show 2 m and 5 m cables and H8PR / H8PS connector versions.
The 10 mm solid shaft is described with 120 N in the radial direction and 50 N in the thrust direction, and the housing is 60 mm in diameter; check the coupling and mounting space.
Check the supply on the machine against the variant: 5-12 V or 12-24 V.
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Availability
Encoder, absolute, 360 ppr, 10-bit, 5-12 VDC, BCD output, 2 m cable, H8PR connector Base
On request
Encoder, absolute, 360 ppr, 10-bit, 5-12 VDC, BCD output, 5 m cable with connector
These steps take an Omron Sentech (STC) camera from the box to a stable first image and on to your own application. They apply across the GigE Vision, USB3 Vision and CoaXPress STC families; the interface only changes how you cable and power the camera.
Download and install the Sentech SDK on the host PC. The package provides StViewer, the viewing and configuration software you use to bring the camera up, and StApi, the programming SDK you integrate later. Because the cameras are GenICam/GenTL-compliant, StApi also registers a GenTL producer, so any GenICam-compliant third-party vision software can discover and drive the camera as an alternative front end.
2. Cable, power and connect the camera
Connect according to the interface. GigE Vision: link to a Gigabit NIC (use PoE or the separate power input) and put the camera and host on the same subnet; for USB3 Vision use a USB 3.x port and a certified cable; for CoaXPress (STC) connect to a CoaXPress frame grabber, which also supplies Power-over-Coax. Then open StViewer and let it enumerate the camera. If a GigE camera does not appear, check the IP configuration and firewall, and on USB3 confirm the host bandwidth and driver.
3. Configure exposure, gain and white balance
Open the device in StViewer and start a live stream. Set exposure and gain for a well-exposed, low-noise image: raise exposure first and only add gain when more light or a faster shutter is not an option, keeping exposure short enough to freeze motion on global-shutter models. On colour cameras, run white balance under your actual production lighting. Adjust the lens aperture and focus on a representative target before tuning anything else.
4. Set the trigger and grab a first image
Start in free-run (continuous) acquisition to confirm a clean, stable image. For inline inspection switch to hardware or software triggering: select the trigger source, set the active edge and any delay, and wire the strobe or illumination to the camera's I/O so lighting fires with each exposure. Acquire and save a frame in StViewer; this saved image is your reference for the SDK stage and for downstream inspection.
5. Move to the StApi SDK (or any GenICam software)
Once the image is stable, reproduce the same settings in code. Use StApi to open the device, apply the GenICam features you validated in StViewer (exposure, gain, trigger, pixel format) and grab frames into your application via the bundled C++, C, C#/.NET or Python interfaces; the included samples are the fastest starting point. Prefer a different stack? The same GenICam/GenTL camera works with third-party vision libraries. With a reliable feed, you can route it into a deep-learning inspection such as Rosepetal for AI-based defect detection.
Frequently asked questions
256–360 steps per revolution (256, 360), with BCD / Gray code output.
A solid shaft with a 10 mm diameter in a 60 mm housing.
The shaft is described as stronger and more durable than on previous E6F encoders, at 120 N in the radial direction and 50 N in the thrust direction.
Drip-proof construction that meets IP64F standards.
The output is NPN or PNP, and the supply is 5-12 V / 12-24 V depending on the variant.