The Omron E6C3-A is an absolute rotary encoder in a 50 mm diameter housing with an 8 mm solid shaft. The resolution is 256–1024 steps per revolution (256, 360, 720, 1024), and the position is delivered as a Gray code output over a parallel interface. It is described as an improved water-resistant encoder with an IP65f drip-proof, oil-proof construction (IP65f as stated by Omron).
The output is NPN or PNP, and the supply is 12-24 V. The order codes show NPN open collector versions at 256, 360 and 720 ppr and a PNP open collector version at 360 ppr, all with Gray code output and a 2 m cable; a 1024ppr version with Gray code output is also shown. The connection is a cable or system connector (model-dependent), so the connection style depends on the model chosen.
An absolute encoder reports shaft position directly as a code value rather than a pulse count, and here the value is read over parallel Gray code lines. In vision installations that gives the controller a position reading of a rotary axis, such as a turntable or indexing stage, that image capture or handling steps can be tied to.
Best for
Rotary axes where the controller reads position as a parallel Gray code value
Locations that call for IP65f drip-proof, oil-proof construction (as stated by Omron)
Turntables or rotary stages with an 8 mm shaft
PLC inputs that accept NPN or PNP signals on a 12-24 V supply
Selection notes
Pick the resolution from 256, 360, 720 or 1024 steps per revolution; each is ordered through its own code.
Match the output type, NPN or PNP, to the controller's parallel inputs; the order codes show NPN open collector and PNP open collector models.
The output is parallel Gray code, so the controller needs parallel inputs to read it.
The supply is 12-24 V, and the connection is cable or system connector depending on the model.
The shaft is solid and 8 mm in diameter in a 50 mm housing; check the coupling and mounting space.
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
These steps take an Omron Sentech (STC) camera from the box to a stable first image and on to your own application. They apply across the GigE Vision, USB3 Vision and CoaXPress STC families; the interface only changes how you cable and power the camera.
Download and install the Sentech SDK on the host PC. The package provides StViewer, the viewing and configuration software you use to bring the camera up, and StApi, the programming SDK you integrate later. Because the cameras are GenICam/GenTL-compliant, StApi also registers a GenTL producer, so any GenICam-compliant third-party vision software can discover and drive the camera as an alternative front end.
2. Cable, power and connect the camera
Connect according to the interface. GigE Vision: link to a Gigabit NIC (use PoE or the separate power input) and put the camera and host on the same subnet; for USB3 Vision use a USB 3.x port and a certified cable; for CoaXPress (STC) connect to a CoaXPress frame grabber, which also supplies Power-over-Coax. Then open StViewer and let it enumerate the camera. If a GigE camera does not appear, check the IP configuration and firewall, and on USB3 confirm the host bandwidth and driver.
3. Configure exposure, gain and white balance
Open the device in StViewer and start a live stream. Set exposure and gain for a well-exposed, low-noise image: raise exposure first and only add gain when more light or a faster shutter is not an option, keeping exposure short enough to freeze motion on global-shutter models. On colour cameras, run white balance under your actual production lighting. Adjust the lens aperture and focus on a representative target before tuning anything else.
4. Set the trigger and grab a first image
Start in free-run (continuous) acquisition to confirm a clean, stable image. For inline inspection switch to hardware or software triggering: select the trigger source, set the active edge and any delay, and wire the strobe or illumination to the camera's I/O so lighting fires with each exposure. Acquire and save a frame in StViewer; this saved image is your reference for the SDK stage and for downstream inspection.
5. Move to the StApi SDK (or any GenICam software)
Once the image is stable, reproduce the same settings in code. Use StApi to open the device, apply the GenICam features you validated in StViewer (exposure, gain, trigger, pixel format) and grab frames into your application via the bundled C++, C, C#/.NET or Python interfaces; the included samples are the fastest starting point. Prefer a different stack? The same GenICam/GenTL camera works with third-party vision libraries. With a reliable feed, you can route it into a deep-learning inspection such as Rosepetal for AI-based defect detection.
Frequently asked questions
256–1024 steps per revolution, with values of 256, 360, 720 and 1024.
A Gray code output over a parallel interface, with NPN or PNP output type.
The supply is 12-24 V and the solid shaft has an 8 mm diameter.
IP65f (as stated by Omron), described as a drip-proof, oil-proof construction.
Through a cable or a system connector, depending on the model.