Omron E6CP-A absolute rotary encoder — 50 mm housing diameter, 256 steps per revolution, 6 mm solid shaft, NPN output, 5-12 V / 12-24 V supply, cable or system connector connection (model-dependent).
The Omron E6CP-A is a low-cost absolute rotary encoder with a 50 mm external diameter and a 6 mm solid shaft. It has a resolution of 256 steps per revolution (8-bit) with Gray code output over a parallel interface, and it uses a lightweight plastic body.
The output is NPN, and the supply is 5-12 V / 12-24 V depending on the variant. The order codes show 256ppr, 8-bit versions with a 5-12 VDC model on a 2 m cable and 12-24 VDC models on 2 m and 5 m cables, plus 12-24 VDC models with an H8PS connector on a 2 m or 5 m cable. The connection is a cable or system connector (model-dependent), so the supply range and connection style are selected through the order code.
An absolute encoder reports the shaft position as a code value rather than counting pulses, and here the value is read as parallel Gray code. In vision installations this gives a control system a position reading of a rotary axis, such as a rotating stage, to which image capture or handling steps can be tied. With 256 steps per revolution it suits axes where that position step is sufficient.
Best for
Rotary axes needing a parallel Gray code position at 256 steps per revolution (8-bit)
Cost-conscious designs that can use a lightweight plastic-body encoder
Controllers with NPN-type inputs
Installations that need a cable or an H8PS connector connection, depending on the model
Selection notes
Resolution is 256 steps per revolution (8-bit); check that this is fine enough for the rotary position your application needs.
The output is NPN with Gray code over parallel lines; confirm the controller input suits this.
Select the supply range, 5-12 V or 12-24 V, via the order code.
Select the connection via the order code: 2 m or 5 m cable, with or without an H8PS connector.
The shaft is solid and 6 mm in diameter in a 50 mm housing; plan the coupling and mounting space.
Specifications: General
Brand
Omron
Sensor type
Encoder
Encoder type
Absolute (resolution per rotation)
Specifications: Performance
Absolute resolution
256 steps per revolution; Gray code output
Specifications: Interface
Communication
Parallel (Gray code output)
Connection
Cable or system connector (model-dependent)
Specifications: Electrical
Supply voltage
5-12 V / 12-24 V
Specifications: Mechanical
Shaft
Solid shaft, 6 mm diameter
Shaft / bore diameter
6 mm
Housing diameter
50 mm
Specifications: Output
Output type
NPN
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Availability
Encoder, absolute, 256ppr, 8-bit, 5-12 VDC, gray code output, 2 m cable Base
These steps take an Omron Sentech (STC) camera from the box to a stable first image and on to your own application. They apply across the GigE Vision, USB3 Vision and CoaXPress STC families; the interface only changes how you cable and power the camera.
Download and install the Sentech SDK on the host PC. The package provides StViewer, the viewing and configuration software you use to bring the camera up, and StApi, the programming SDK you integrate later. Because the cameras are GenICam/GenTL-compliant, StApi also registers a GenTL producer, so any GenICam-compliant third-party vision software can discover and drive the camera as an alternative front end.
2. Cable, power and connect the camera
Connect according to the interface. GigE Vision: link to a Gigabit NIC (use PoE or the separate power input) and put the camera and host on the same subnet; for USB3 Vision use a USB 3.x port and a certified cable; for CoaXPress (STC) connect to a CoaXPress frame grabber, which also supplies Power-over-Coax. Then open StViewer and let it enumerate the camera. If a GigE camera does not appear, check the IP configuration and firewall, and on USB3 confirm the host bandwidth and driver.
3. Configure exposure, gain and white balance
Open the device in StViewer and start a live stream. Set exposure and gain for a well-exposed, low-noise image: raise exposure first and only add gain when more light or a faster shutter is not an option, keeping exposure short enough to freeze motion on global-shutter models. On colour cameras, run white balance under your actual production lighting. Adjust the lens aperture and focus on a representative target before tuning anything else.
4. Set the trigger and grab a first image
Start in free-run (continuous) acquisition to confirm a clean, stable image. For inline inspection switch to hardware or software triggering: select the trigger source, set the active edge and any delay, and wire the strobe or illumination to the camera's I/O so lighting fires with each exposure. Acquire and save a frame in StViewer; this saved image is your reference for the SDK stage and for downstream inspection.
5. Move to the StApi SDK (or any GenICam software)
Once the image is stable, reproduce the same settings in code. Use StApi to open the device, apply the GenICam features you validated in StViewer (exposure, gain, trigger, pixel format) and grab frames into your application via the bundled C++, C, C#/.NET or Python interfaces; the included samples are the fastest starting point. Prefer a different stack? The same GenICam/GenTL camera works with third-party vision libraries. With a reliable feed, you can route it into a deep-learning inspection such as Rosepetal for AI-based defect detection.
Frequently asked questions
256 steps per revolution (8-bit), with Gray code output.
The output is NPN, and the supply is 5-12 V / 12-24 V depending on the variant.
A solid shaft with a 6 mm diameter in a 50 mm housing.
The connection is a cable or system connector, depending on the model. The order codes show 2 m and 5 m cables, including versions with an H8PS connector.
It is a lightweight construction using a plastic body.