The Datalogic AMTX58-S is an absolute multi-turn rotary encoder in the solid-shaft version, with a Ø10 mm shaft and a Ø58 mm housing in metal (aluminium) measuring Ø58 mm x 51 mm. The resolution is listed as 27 bit (8192 cpr × 16384 turns), so the position value covers the angle within a revolution and up to 16384 turns.
Its communication options are EtherNet/IP, PROFINET and EtherCAT. The three order codes list one variant per protocol (Ethernet-IP, ProfiNet and EtherCAT), each described as having radial connectors, and the listed connection is an M12 connector. The protocol is therefore selected by order code.
The supply is 7.5-34 VDC. In machine vision, encoders in general serve as the position reference for a rotating axis or conveyor drive; this one delivers it to the controller as a digital value over the network.
Best for
Position feedback on a rotating axis with a Ø10 mm shaft end (solid-shaft mounting).
Multi-turn positioning that needs up to 16384 turns at 8192 cpr (27 bit).
Machines on EtherNet/IP, PROFINET or EtherCAT networks that read position over the network.
Providing a position reference for conveyor or axis drives in inspection lines, read through the controller.
Installations that fit a Ø58 mm x 51 mm aluminium-housing encoder with an M12 connector.
Selection notes
Choose the network first, because it is set by the order code: EtherNet/IP, ProfiNet or EtherCAT, each listed with radial connectors.
Make sure the controller can read a 27 bit value (8192 cpr × 16384 turns).
The shaft is Ø10 mm solid, so the mating drive must suit that diameter, and the housing is Ø58 mm x 51 mm.
Plan for an M12 connection and a supply within 7.5-34 VDC.
Check the manufacturer datasheet for the M12 pin assignment before designing the cabling.
Specifications: General
Brand
Datalogic
Sensor type
Encoder
Encoder type
Absolute multi-turn
Specifications: Performance
Absolute resolution
27 bit (8192 cpr × 16384 turns)
Specifications: Interface
Communication
EtherNet/IP, PROFINET, EtherCAT
Connection
M12 connector
Specifications: Electrical
Supply voltage
7.5-34 VDC
Specifications: Mechanical
Shaft
Solid shaft
Shaft / bore diameter
Ø10 mm
Dimensions
Ø58 mm x 51 mm
Housing diameter
Ø58 mm
Housing material
Metal - Aluminium
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Connection
Shaft / bore diameter
Absolute resolution
Communication ●
Availability
Encoder Absolute multiturn - shaft 10 mm -27 bit - Ethernet-IP with radial connectors Base
M12 connector
Ø10 mm
27 bit
EtherNet/IP
On request
Encoder Absolute multiturn - shaft 10 mm -27 bit - ProfiNet with radial connectors
M12 connector
Ø10 mm
27 bit
PROFINET
On request
Encoder Absolute multiturn - shaft 10 mm -27 bit - EtherCAT with radial connectors
M12 connector
Ø10 mm
27 bit
EtherCAT
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
1. Install the IMPACT Software Suite and connect the camera
Install the IMPACT Software Suite on your PC, which provides both the configuration/viewer tools and the SDK. For a GigE Vision model (E100, M or U series), connect it to a dedicated NIC and, for USB3 models, use a certified USB3 cable and port. Power the camera and confirm it enumerates.
2. Bring the camera online and verify the link
For GigE Vision, put the camera and the host NIC on the same subnet (a static IP on the camera matching the NIC range is the most reliable starting point); for USB3, confirm the device is recognized. Open the IMPACT viewer/device tool, discover the camera, and verify a stable connection before streaming. Enabling jumbo frames on the NIC helps GigE throughput.
3. Set exposure, gain and trigger, then grab a first image
In the IMPACT tools, start a live stream and adjust exposure and gain until the image is well-lit without saturation; set white balance on color models. Begin in free-run (continuous) mode to confirm imaging, then switch to hardware or software trigger as your application requires. Capture and save a reference image once the scene looks correct.
4. Build a vision tool or move to the SDK/API
Use the IMPACT point-and-click vision tools to assemble an inspection, or use the IMPACT SDK to access the camera and results programmatically and feed them into your HMI/PLC application. As these are GenICam/GenTL-compliant devices, you can alternatively drive them from any GenICam-compliant third-party vision library if your pipeline standardizes on one.
5. Route the stable feed to deep-learning inspection (optional)
Once you have a stable, repeatable image, the feed can be sent to a deep-learning inspection platform such as Rosepetal for defect detection or classification tasks that go beyond rule-based tooling. Keep lighting, optics and trigger timing fixed so the images reaching the model stay consistent.
Frequently asked questions
The resolution is 27 bit (8192 cpr × 16384 turns).
EtherNet/IP, PROFINET and EtherCAT, each ordered as a separate variant with radial connectors.
It is a solid shaft of Ø10 mm, in a Ø58 mm housing in metal (aluminium) measuring Ø58 mm x 51 mm.
The supply is 7.5-34 VDC and the connection is an M12 connector.