The Datalogic DATAVS2-ID is a cubic vision sensor from the DataVS2 family configured for identification. Its tool set is "Identification: barcode / Data Matrix / QR / OCV", so it is aimed at reading barcodes, Data Matrix and QR codes and at OCV. The housing measures 52 x 60 x 40 mm and the supply is 24 VDC.
Integrated lighting is a Red LED and the working distance is 500 mm nominal. The lens is chosen through the order code: four codes cover 6, 8, 12 and 16 mm lenses, each a cubic vision sensor with Ethernet and RS232 for identification. Because the lens is fixed when ordering, it should be matched to the code or text size and to the area to be covered at the 500 mm nominal distance.
Communication is Ethernet and RS-232, and the sensor provides 3x PNP outputs. Results can be passed to a host over either link, while the PNP outputs give discrete signals that a PLC input can read, for example as a result flag after a code read or an OCV check.
Best for
Reading barcodes, Data Matrix and QR codes at a station with the code at the 500 mm nominal working distance
OCV alongside code reading, using the same "Identification: barcode / Data Matrix / QR / OCV" tool set
Identification stations where results go to a host over Ethernet or RS-232 and discrete signals go to a PLC through the 3x PNP outputs
Space-constrained stations that suit a 52 x 60 x 40 mm body with integrated Red LED lighting
Selection notes
Choose the lens by order code (6, 8, 12 or 16 mm) according to the size of the code or text and how much of the scene must fit in view at the 500 mm nominal working distance.
Illumination is Red LED. Evaluate the contrast of your labels, print or direct marking under red light on real samples before committing to the station layout.
The 3x PNP outputs need PLC or relay inputs that accept PNP signals, and the unit is supplied at 24 VDC.
Pick the host link that fits the machine: Ethernet for network integration, RS-232 where a serial device or controller consumes the read data.
Confirm the field of view of each lens at the nominal distance in the manufacturer datasheet before fixing the mounting position.
Specifications: General
Brand
Datalogic
Inspection tools
Identification: barcode / Data Matrix / QR / OCV
Specifications: Interface
Communication
Ethernet, RS-232
Specifications: Optical
Integrated lighting
Red LED
Working distance
500 mm nominal
Specifications: Electrical
Supply voltage
24 VDC
Specifications: Output
Output type
3x PNP
Specifications: Mechanical
Dimensions
52 x 60 x 40 mm
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
lens ●
Integrated lighting
Communication
Availability
Vision Sensor Cubic 6 mm lens, ethernet & RS232, identification Base
6 mm lens
Red LED
Ethernet + RS-232
On request
Vision Sensor Cubic 8 mm lens, ethernet & RS232, identification
8 mm lens
Red LED
Ethernet + RS-232
On request
Vision Sensor Cubic 12 mm lens, ethernet & RS232, identification
12 mm lens
Red LED
Ethernet + RS-232
On request
Vision Sensor Cubic 16 mm lens, ethernet & RS232, identification
16 mm lens
Red LED
Ethernet + RS-232
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
1. Install the IMPACT Software Suite and connect the camera
Install the IMPACT Software Suite on your PC, which provides both the configuration/viewer tools and the SDK. For a GigE Vision model (E100, M or U series), connect it to a dedicated NIC and, for USB3 models, use a certified USB3 cable and port. Power the camera and confirm it enumerates.
2. Bring the camera online and verify the link
For GigE Vision, put the camera and the host NIC on the same subnet (a static IP on the camera matching the NIC range is the most reliable starting point); for USB3, confirm the device is recognized. Open the IMPACT viewer/device tool, discover the camera, and verify a stable connection before streaming. Enabling jumbo frames on the NIC helps GigE throughput.
3. Set exposure, gain and trigger, then grab a first image
In the IMPACT tools, start a live stream and adjust exposure and gain until the image is well-lit without saturation; set white balance on color models. Begin in free-run (continuous) mode to confirm imaging, then switch to hardware or software trigger as your application requires. Capture and save a reference image once the scene looks correct.
4. Build a vision tool or move to the SDK/API
Use the IMPACT point-and-click vision tools to assemble an inspection, or use the IMPACT SDK to access the camera and results programmatically and feed them into your HMI/PLC application. As these are GenICam/GenTL-compliant devices, you can alternatively drive them from any GenICam-compliant third-party vision library if your pipeline standardizes on one.
5. Route the stable feed to deep-learning inspection (optional)
Once you have a stable, repeatable image, the feed can be sent to a deep-learning inspection platform such as Rosepetal for defect detection or classification tasks that go beyond rule-based tooling. Keep lighting, optics and trigger timing fixed so the images reaching the model stay consistent.
Frequently asked questions
The tool set is "Identification: barcode / Data Matrix / QR / OCV". It is the identification version of the DataVS2 cubic vision sensor.
There are 4 order codes, with 6, 8, 12 and 16 mm lenses. Each is the cubic vision sensor with Ethernet and RS232 for identification.
Communication is Ethernet and RS-232, and the outputs are 3x PNP. The supply voltage is 24 VDC.
Yes, it has integrated Red LED lighting. The working distance is 500 mm nominal.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE