Skip to content
Omron FQ2-CH machine vision vision sensor
  • Recommended by AIS Vision

Omron FQ2-CH vision sensor (OCR sensor)

FQ2-CH

Omron FQ2-CH vision sensor (OCR sensor) — 350,000 pixels; monochrome; tools: ocr / ocv; Ethernet / EtherNet/IP / PROFINET + digital I/O; IP67; 21.6 to 26.4 VDC (including ripple).

Brand
Omron
Inspection tools
OCR ⋅ Alphabet A to Z ⋅ Number 0 to 9 ⋅ Symbol ' - . : / Model dictionary
Resolution
350,000 pixels
Mono / color
Monochrome
Integrated lighting
White (pulse)
Field of view
Lens variants: Narrow View / Standard View / Wide View (Long-distance) / Wide View (Short-distance)
Communication
Ethernet TCP no-protocol, Ethernet UDP no-protocol, Ethernet FINS/TCP no-protocol, EtherNet/IP, PLC Link, or PROFINET; 100Base-TX/10Base-T; digital I/O (7 inputs, 3 outputs)
Output type
NPN / PNP
Supply voltage
21.6 to 26.4 VDC (including ripple)
Operating temperature
Operating: 0 to 40°C, Storage: -25 to 65°C (with no icing or condensation)
IP rating
IP67
Weight
Narrow View/Standard View: Approx.160 g Wide View: Approx. 150 g

Technical overview

The Omron FQ2-CH is the Optical Character Recognition Sensor of the Omron FQ2 vision sensor family. It combines a 350,000-pixel monochrome image with white (pulse) integrated lighting. The tool entry lists OCR with Alphabet A to Z, Number 0 to 9 and the symbols ' - . : /, together with a Model dictionary, and the technical summary names ocr / ocv as the tools.

The optical set-up is chosen through four lens variants: Narrow View, Standard View, Wide View (Long-distance) and Wide View (Short-distance). The order codes pair each variant with either NPN or PNP output, giving eight order codes, so lens variant and output polarity are fixed when the unit is ordered. Narrow View/Standard View units are listed at approx. 160 g and Wide View units at approx. 150 g. The sensor stores 32 scenes, so several character-reading set-ups can be kept on the unit.

Communication is Ethernet TCP no-protocol, Ethernet UDP no-protocol, Ethernet FINS/TCP no-protocol, EtherNet/IP, PLC Link, or PROFINET over 100Base-TX/10Base-T, plus digital I/O with 7 inputs and 3 outputs, with NPN / PNP output type. The supply is 21.6 to 26.4 VDC (including ripple), the enclosure is IP67, and the operating range is 0 to 40°C (storage -25 to 65°C, with no icing or condensation). Set-up uses the PC tool for FQ, which is listed for Microsoft Windows XP Home Edition/Professional SP2 or higher (32-bit version) and Microsoft Windows 7 Home Premium or higher (32-bit/64-bit version).

Best for

  • Reading printed or marked characters (alphabet A to Z, numbers 0 to 9) with the OCR tool.
  • Verifying marked text using the ocr / ocv tools named in the technical summary.
  • Marking that includes the symbols ' - . : / alongside letters and digits.
  • Stations that switch between products by recalling one of the 32 stored scenes.
  • Lines that report results to PLCs over EtherNet/IP, PROFINET or Ethernet TCP/UDP/FINS links, or through the digital I/O (7 inputs, 3 outputs).

Selection notes

  • Pick the lens variant (Narrow View, Standard View, Wide View (Long-distance) or Wide View (Short-distance)) from the character size and the mounting distance available at the station; the variant is part of the order code, so confirm the field of view and working distance of each lens variant in the manufacturer datasheet.
  • Choose NPN or PNP output to match the PLC input type; both are listed for every lens variant.
  • The built-in light is white (pulse) and the image is monochrome, so confirm that the marking contrasts well with its background under that illumination.
  • The listed character set is alphabet A to Z, numbers 0 to 9 and the symbols ' - . : /; check that the marking on your parts stays within it.
  • Allow for a 21.6 to 26.4 VDC supply (including ripple), an IP67 enclosure and a 0 to 40°C operating range at the mounting position, and make sure the programming PC matches the PC tool for FQ systems: Microsoft Windows XP Home Edition/Professional SP2 or higher (32-bit version) and Microsoft Windows 7 Home Premium or higher (32-bit/64-bit version).

Specifications: General
BrandOmron
Inspection toolsOCR ⋅ Alphabet A to Z ⋅ Number 0 to 9 ⋅ Symbol ' - . : / Model dictionary

Specifications: Sensor
Resolution350,000 pixels
Mono / colorMonochrome

Specifications: Performance
Stored programs32 scenes

Specifications: Interface
CommunicationEthernet TCP no-protocol, Ethernet UDP no-protocol, Ethernet FINS/TCP no-protocol, EtherNet/IP, PLC Link, or PROFINET; 100Base-TX/10Base-T; digital I/O (7 inputs, 3 outputs)

Specifications: Optical
Integrated lightingWhite (pulse)
Field of viewLens variants: Narrow View / Standard View / Wide View (Long-distance) / Wide View (Short-distance)

Specifications: Electrical
Supply voltage21.6 to 26.4 VDC (including ripple)

Specifications: Environment
Operating temperatureOperating: 0 to 40°C, Storage: -25 to 65°C (with no icing or condensation)
IP ratingIP67

Specifications: Output
Output typeNPN / PNP

Specifications: Mechanical
WeightNarrow View/Standard View: Approx.160 g Wide View: Approx. 150 g

Specifications: Software
Operating systemsPC tool for FQ: Microsoft Windows XP Home Edition/Professional SP2 or higher (32-bit version); Microsoft Windows 7 Home Premium or higher (32-bit/64-bit version)

Frequently asked questions

Related technical guides

Often used with

Ethernet / GigE cables

Industrial Ethernet / GigE cables with locking connectors. Check length and flex rating against your installation.

All cables →

I/O and power cables

Industrial I/O and power cables with locking connectors. Check length and flex rating against your installation.

All cables →

Mounts and housings

Brackets and protective housings to fix and protect the device on the line.

All mounts and housings →
  • Omron FQ2-S4 machine vision vision sensor
    • Search, shape search II, sensitive search, area, color data, edge position, edge pitch, edge width, labeling, OCR, Bar code, 2D-code, 2D-code (DMP), and Model dictionary
    • 350,000 pixels / 760,000 pixels / 1.3 million pixels
    • Lens variants: Narrow View / Standard View / Wide View (Long-distance) / Wide View (Short-distance) / C-mount
    • Ethernet TCP no-protocol, Ethernet UDP no-protocol, Ethernet FINS/TCP no-protocol, EtherNet/IP, PLC Link, or PROFINET; 100Base-TX/10Base-T; digital I/O (7 inputs, 3 outputs)
    • Recommended by AIS Vision
    On request
    View
  • Hikrobot MV-SC2004EM-06S-WBN-Mini machine vision vision sensor
    HikrobotHikrobot MV-SC2004EM-06S-WBN-MiniMV-SC2004EM-06S-WBN-Mini
    • Measurement, Existence, Count, Recognition, Location tool groups
    • 0.4 MP (704 × 540 px)
    • RS-232, TCP, UDP, FTP, PROFINET, Modbus, EtherNet/IP, MELSEC/SLMP, FINS, Keyence KV
    • IP65
    • Recommended by AIS Vision
    On request
    View

AIS Vision · Integration

We validate camera + lens + lighting