The Datalogic ENC41-H is an incremental rotary encoder in a blind hollow-shaft version with a Ø6 mm shaft/bore and a Ø41 mm housing (Ø41x44 mm) made of Fibre glass / Aluminium. Resolution is 100–4096 PPR in 7 fixed values, and each value has its own order code: 100, 360, 500, 1000, 1024, 2048 and 4096 PPR.
Electrically, the output is Push-pull / Line driver with a 5-30 VDC supply, and the connection is a 1.5 m cable on all seven order codes. The PPR value fixes how many pulses the encoder delivers per shaft revolution, so it should be chosen together with the receiving device's input and the finest position step the application needs.
In vision systems an incremental encoder's general role is to convert motion into a pulse train. A controller or triggering hardware can count those pulses to follow conveyor travel or to time image capture, for example when line-scan acquisition has to follow the speed of the moving product. The Ø6 mm blind hollow shaft is mounted directly on a shaft end of that diameter.
Best for
Conveyor or roller position and speed feedback where 100–4096 PPR is enough
Shaft ends of Ø6 mm that accept a blind hollow-shaft encoder
Systems whose receiving input accepts a Push-pull or Line driver output
Machines with room for a Ø41x44 mm encoder body
Selection notes
Pick the PPR from the seven values (100, 360, 500, 1000, 1024, 2048, 4096 PPR); each one is a separate order code.
The output is Push-pull / Line driver; confirm that the receiving input and its voltage level suit the 5-30 VDC supply you intend to use.
The shaft/bore is Ø6 mm and the housing is Ø41x44 mm; verify the shaft end and mounting space.
All seven order codes are supplied with a 1.5 m cable, so plan terminations or junction points at the cable end.
Compare the PPR with the roller or wheel size and the position resolution the application requires before ordering.
Specifications: General
Brand
Datalogic
Sensor type
Encoder
Encoder type
Incremental
Specifications: Performance
Pulses per revolution
100–4096 PPR (7 fixed values)
Specifications: Interface
Connection
1.5 m cable
Specifications: Electrical
Supply voltage
5-30 VDC
Specifications: Mechanical
Shaft
Blind hollow shaft
Shaft / bore diameter
Ø6 mm
Dimensions
Ø41x44 mm
Housing diameter
Ø41 mm
Housing material
Fibre glass / Aluminium
Specifications: Output
Output type
Push-pull / Line driver
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Connection
Shaft / bore diameter
Pulses per revolution ●
Availability
Encoder incremental 41 mm - blind hollow 6 mm -100PPr - cable Base
1.5 m cable
Ø6 mm
100 PPR
On request
Encoder incremental 41 mm - blind hollow 6 mm -360PPr - cable
1.5 m cable
Ø6 mm
360 PPR
On request
Encoder incremental 41 mm - blind hollow 6 mm -500PPr - cable
1.5 m cable
Ø6 mm
500 PPR
On request
Encoder incremental 41 mm - blind hollow 6 mm -1000PPr - cable
1.5 m cable
Ø6 mm
1000 PPR
On request
Encoder incremental 41 mm - blind hollow 6 mm -1024PPr - cable
1.5 m cable
Ø6 mm
1024 PPR
On request
Encoder incremental 41 mm - blind hollow 6 mm -2048PPr - cable
1.5 m cable
Ø6 mm
2048 PPR
On request
Encoder incremental 41 mm - blind hollow 6 mm -4096PPr - cable
1.5 m cable
Ø6 mm
4096 PPR
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
1. Install the IMPACT Software Suite and connect the camera
Install the IMPACT Software Suite on your PC, which provides both the configuration/viewer tools and the SDK. For a GigE Vision model (E100, M or U series), connect it to a dedicated NIC and, for USB3 models, use a certified USB3 cable and port. Power the camera and confirm it enumerates.
2. Bring the camera online and verify the link
For GigE Vision, put the camera and the host NIC on the same subnet (a static IP on the camera matching the NIC range is the most reliable starting point); for USB3, confirm the device is recognized. Open the IMPACT viewer/device tool, discover the camera, and verify a stable connection before streaming. Enabling jumbo frames on the NIC helps GigE throughput.
3. Set exposure, gain and trigger, then grab a first image
In the IMPACT tools, start a live stream and adjust exposure and gain until the image is well-lit without saturation; set white balance on color models. Begin in free-run (continuous) mode to confirm imaging, then switch to hardware or software trigger as your application requires. Capture and save a reference image once the scene looks correct.
4. Build a vision tool or move to the SDK/API
Use the IMPACT point-and-click vision tools to assemble an inspection, or use the IMPACT SDK to access the camera and results programmatically and feed them into your HMI/PLC application. As these are GenICam/GenTL-compliant devices, you can alternatively drive them from any GenICam-compliant third-party vision library if your pipeline standardizes on one.
5. Route the stable feed to deep-learning inspection (optional)
Once you have a stable, repeatable image, the feed can be sent to a deep-learning inspection platform such as Rosepetal for defect detection or classification tasks that go beyond rule-based tooling. Keep lighting, optics and trigger timing fixed so the images reaching the model stay consistent.
Frequently asked questions
The resolution is 100–4096 PPR in 7 fixed values. The order codes are 100, 360, 500, 1000, 1024, 2048 and 4096 PPR.
The output is Push-pull / Line driver and the supply is 5-30 VDC.
It is a blind hollow-shaft version with a Ø6 mm shaft/bore.
The connection is a 1.5 m cable.
The housing is Ø41 mm, with overall dimensions of Ø41x44 mm, in Fibre glass / Aluminium.