Datalogic Matrix 220 DPM 7 mm — fixed-mount DPM reader; 2D imager; 1.2 MP; 7 mm optics; reads 40–300 mm; 45 fps; DPM codes; IP65, IP67; interfaces Ethernet / RS-232 / PROFINET / EtherNet/IP / Modbus TCP / Digital I/O; operating 0 to 50 °C (datalogic.com); datasheet: 0 to 50 °C for the "X" P/Ns, -10 to 50 °C for the other P/Ns. 5 order codes on datalogic.com.
With the 7 mm lens the 38.3° view, if horizontal, gives a field of about 0.69 × distance: 28 mm wide at 40 mm and 208 mm at 300 mm. The pixel footprint then runs from 27.8 ÷ 1280 ≈ 0.022 mm to 208 ÷ 1280 ≈ 0.16 mm. For a small DPM code that matters: an example 0.4 mm module spans 0.4 ÷ 0.163 ≈ 2.5 px at 300 mm but about 18 px at 40 mm.
The all-in-one illuminator (12 diffused, 2 polarized and 2 non-polarized LEDs, red or blue) is configurable: diffused light evens out highlights, and the polarizer reduces glare on engraved, embossed or laser-etched marks.
Best for
Parts presented with position scatter, where the 38.3° view keeps the mark in frame at the cost of fewer pixels per module.
Curved or machined metal such as shafts or housings, using the diffused LEDs to flatten highlights.
Ethernet-only wiring with the PoE order codes, accepting 1 input and no outputs.
Selection notes
Red or blue is fixed by the order code, and coloured, anodised or textured surfaces respond differently to each, so test both on samples.
For AI-based decoding of DPM codes (DecodeX), the Matrix 220 XAI DPM 7 mm has the same 38.3° optics, at 5.1 W max against 4.2 W here.
Specifications: General
Brand
Datalogic
Reader type
Code reader
Form factor
Compact fixed-mount 2D imager
Specifications: Sensor
Resolution
1.2 MP (1280 × 960 px)
Horizontal resolution
1280 px
Specifications: Performance
FPS
45 frames/s
Specifications: Interface
Communication
Ethernet 10/100 (TCP/IP, UDP, FTP, PROFINET IO, EtherNet/IP, Modbus TCP, OPC UA) + RS-232/RS-422 FD main + aux RS-232; PoE models: Ethernet PoE (Mode A / B) + aux RS-232; ID-NET; 2 inputs / 3 outputs (PoE models: 1 input, no outputs)
All-in-one multi-light DPM illuminator: red or blue light with embedded polarizer and diffuser (12 diffused + 2 polarized + 2 non-polarized LEDs, configurable)
Illumination colour
Red / Blue (per order code)
Specifications: Electrical
Power over cable (PoE / PoCXP / PoCL)
PoE (Mode A and Mode B, 48 VDC) on the -040 POE order codes
Supply voltage
10 – 30 VDC (all models except PoE); 48 VDC PoE
Power consumption
4.2 W max (10 – 30 VDC); 4.8 W max (PoE models, 48 VDC)
Specifications: Environment
Operating temperature
0 to 50 °C (datalogic.com); datasheet: 0 to 50 °C for the "X" P/Ns, -10 to 50 °C for the other P/Ns
DPM codes (engraved, embossed, laser-etched on metal, plastic, glass); 1D: all standard symbologies; 2D: Data Matrix, QR Code, Micro QR, Maxicode, Aztec, Dot Code; postal codes
Specifications: Mechanical
Dimensions
78 x 47 x 38 mm (connector at 0°); 57 x 47 x 58 mm (connector at 90°)
Weight
173 g
Housing material
Aluminium case, plastic protective window cover
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Illumination colour ●
Power over cable (PoE / PoCXP / PoCL) ●
Availability
MATRIX 220 382-010 1.2MP DPM-R 7MM ESD X Base
Red (DPM)
—
On request
MATRIX 220 382-040 1.2MP DPM-R 7MM POE
Red (DPM)
PoE (48 VDC)
On request
MATRIX 220 392-010 1.2MP DPM-B 7MM
Blue (DPM)
—
On request
MATRIX 220 392-010 1.2MP DPM-B 7MM ESD X
Blue (DPM)
—
On request
MATRIX 220 392-040 1.2MP DPM-B 7MM POE
Blue (DPM)
PoE (48 VDC)
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
1. Install the IMPACT Software Suite and connect the camera
Install the IMPACT Software Suite on your PC, which provides both the configuration/viewer tools and the SDK. For a GigE Vision model (E100, M or U series), connect it to a dedicated NIC and, for USB3 models, use a certified USB3 cable and port. Power the camera and confirm it enumerates.
2. Bring the camera online and verify the link
For GigE Vision, put the camera and the host NIC on the same subnet (a static IP on the camera matching the NIC range is the most reliable starting point); for USB3, confirm the device is recognized. Open the IMPACT viewer/device tool, discover the camera, and verify a stable connection before streaming. Enabling jumbo frames on the NIC helps GigE throughput.
3. Set exposure, gain and trigger, then grab a first image
In the IMPACT tools, start a live stream and adjust exposure and gain until the image is well-lit without saturation; set white balance on color models. Begin in free-run (continuous) mode to confirm imaging, then switch to hardware or software trigger as your application requires. Capture and save a reference image once the scene looks correct.
4. Build a vision tool or move to the SDK/API
Use the IMPACT point-and-click vision tools to assemble an inspection, or use the IMPACT SDK to access the camera and results programmatically and feed them into your HMI/PLC application. As these are GenICam/GenTL-compliant devices, you can alternatively drive them from any GenICam-compliant third-party vision library if your pipeline standardizes on one.
5. Route the stable feed to deep-learning inspection (optional)
Once you have a stable, repeatable image, the feed can be sent to a deep-learning inspection platform such as Rosepetal for defect detection or classification tasks that go beyond rule-based tooling. Keep lighting, optics and trigger timing fixed so the images reaching the model stay consistent.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE