The VCU06A turns one VCB 2-pole outlet into two: +VDC (pin 1) and GND (pin 2) of the male connector are repeated on each of two female connectors wired in parallel. A 2-pole connection has no Control contact, so both lights are powered together and run continuously.
In parallel, the currents add. Two lights of 0.6 A each, as an example, put 2 × 0.6 A = 1.2 A through the one male connector and the cable behind it, so size the supply and the outlet for the sum, not for one light. Four lengths are available: 30 cm, 50 cm, 1 m and 1.5 m.
Best for
Lighting a part from two opposite sides with two 2-pole lights that share one power outlet at the station.
Adding a second steady light after commissioning without pulling another power cable back to the cabinet.
Stations where both lights always run together, so no individual switching is needed.
Selection notes
The two outputs cannot be switched or dimmed separately through this cable. Lights that need independent behaviour each need their own outlet.
Add up the rated currents of both lights and compare the total with the supply output; ask us for the connector's current rating if the total is high.
More outputs on the same 2-pole wiring: VCU08A gives 3, VCU10A gives 4 and VCU13A gives 5.
Lights with a 3-pole plug use a Control contact that a 2-pole splitter does not carry; for those, the 2-branch VCU07A repeats it.
Specifications: General
Brand
DCM Sistemes
Cable type
Lighting interconnection / adapter cable
Specifications: Interface
Connector A
VCB 2-pole male
Connector B
VCB 2-pole female × 2 (parallel)
Specifications: Mechanical
Cable length
30 cm / 50 cm / 1 m / 1.5 m (longer than 150 cm on request)
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
No. Both female connectors are wired to the same +VDC and GND contacts and a 2-pole connection has no control contact, so both lights always receive the same supply.
30 cm (VCU06A003), 50 cm (VCU06A005), 1 m (VCU06A010) or 1.5 m (VCU06A015), with longer on request.