DCM Sistemes VCU06A splitter cable VCB 2-pole (male) to 2 × VCB 2-pole (female)

VCU06A

DCM Sistemes VCU06A — splitter cable VCB 2-pole (male) to 2 × VCB 2-pole (female); 30 cm / 50 cm / 1 m / 1.5 m; 2-to-2-pole wiring (+VDC, GND).

Brand
DCM Sistemes
Cable type
Lighting interconnection / adapter cable
Cable length
30 cm / 50 cm / 1 m / 1.5 m (longer than 150 cm on request)
Connector A
VCB 2-pole male
Connector B
VCB 2-pole female × 2 (parallel)

Technical overview

The VCU06A turns one VCB 2-pole outlet into two: +VDC (pin 1) and GND (pin 2) of the male connector are repeated on each of two female connectors wired in parallel. A 2-pole connection has no Control contact, so both lights are powered together and run continuously.

In parallel, the currents add. Two lights of 0.6 A each, as an example, put 2 × 0.6 A = 1.2 A through the one male connector and the cable behind it, so size the supply and the outlet for the sum, not for one light. Four lengths are available: 30 cm, 50 cm, 1 m and 1.5 m.

Best for

  • Lighting a part from two opposite sides with two 2-pole lights that share one power outlet at the station.
  • Adding a second steady light after commissioning without pulling another power cable back to the cabinet.
  • Stations where both lights always run together, so no individual switching is needed.

Selection notes

  • The two outputs cannot be switched or dimmed separately through this cable. Lights that need independent behaviour each need their own outlet.
  • Add up the rated currents of both lights and compare the total with the supply output; ask us for the connector's current rating if the total is high.
  • More outputs on the same 2-pole wiring: VCU08A gives 3, VCU10A gives 4 and VCU13A gives 5.
  • Lights with a 3-pole plug use a Control contact that a 2-pole splitter does not carry; for those, the 2-branch VCU07A repeats it.

Specifications: General
BrandDCM Sistemes
Cable typeLighting interconnection / adapter cable

Specifications: Interface
Connector AVCB 2-pole male
Connector BVCB 2-pole female × 2 (parallel)

Specifications: Mechanical
Cable length30 cm / 50 cm / 1 m / 1.5 m (longer than 150 cm on request)

Frequently asked questions

Related technical guides

Often used with

Machine vision lights

Lights that use this kind of cable.

All lighting →
  • DCM Sistemes BKL1010A machine vision lighting
    • Backlight (posterior diffuse / bright field)
    • Available LED colors: white, red (630 nm), green (525 nm), blue (470 nm), IR (850 nm), RGB
    • Continuous (Type C); strobe (Type S) and overdrive (Type i / iBlueDrive) also available
    • IP40 standard (IP65 available as factory modifier)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Basler Light Ring-100OD-White machine vision lighting
    BaslerBasler Standard Light Ring-100OD-WhiteLight Ring-100OD-White
    • Ring light
    • White (5000 K)
    • 67-101 mm
    • Continuous and strobe (internal LED controller, 2 operating modes)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

AIS Vision · Integration

We validate camera + lens + lighting

AIS Vision defines and tests the optimal combination of camera, optics and lighting for your application before you buy.