The VCU07A repeats all three VCC contacts on two female connectors: +VDC on pin 1, GND on pin 2 and Control on pin 3 each go to both branches in parallel. The shared Control line is the part to design around. Both lights get the same control signal and switch together, so this splitter suits two lights that should behave as one lighting group.
On the control side, one output now drives two light inputs, so check it has the capacity, and make sure the supply covers the sum of both lights' currents. Lights that need different timing, such as one switched with the image and one steady, need separate outputs rather than a splitter. The cable is made in 30 cm, 50 cm, 1 m and 1.5 m.
Best for
Two 3-pole lights that should switch together, such as a pair lighting opposite sides of a part.
Extending an existing 3-pole camera or controller output to a second light without using another control channel.
Stations where identical switching matters, since both lights receive the same Control signal and cannot drift apart in timing.
Selection notes
The branches are not independent: one control signal, one supply. Lights that must switch independently each need their own output.
The 2-pole VCU06A also has two outputs but no Control contact. Choose by whether your lights have a 3-pole or 2-pole plug.
For three, four or five 3-pole lights the same wiring is available as VCU09A, VCU11A and VCU12A.
Specifications: General
Brand
DCM Sistemes
Cable type
Lighting interconnection / adapter cable
Specifications: Interface
Connector A
VCC 3-pole male
Connector B
VCC 3-pole female × 2 (parallel)
Specifications: Mechanical
Cable length
30 cm / 50 cm / 1 m / 1.5 m (longer than 150 cm on request)
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Yes. Pin 3 (Control) of the male connector goes to pin 3 of both females in parallel, as do +VDC (pin 1) and GND (pin 2), so the two lights switch together.
The male connector carries the combined current of both lights, so the supply and the outlet must be rated for the sum of the two, not for one.