The VCU03A lets a 2-pole DCM Sistemes light run from a 3-pole VCC outlet. +VDC passes from VCC pin 1 to VCB pin 1 and GND from pin 2 to pin 2; the Control contact on VCC pin 3 has nothing to connect to on the VCB female, so it stops at the adapter.
The consequence is that the light is only powered, never controlled. It stays on whenever +VDC is present on the outlet, and nothing on the camera or controller side can switch it through the Control line. If the light has to follow the camera, use a 3-pole light on a path that carries Control, such as the VCU05A from a camera's M12 connector or the VCU07A splitter. The adapter comes in 30 cm, 50 cm, 1 m and 1.5 m, with longer on request.
Best for
Running a 2-pole light that only needs constant power from a 3-pole DCM Sistemes outlet, without a custom-wired connector.
Installations that mix 3-pole and 2-pole lights on one output, because each light then plugs in without rewiring the outlet.
Adding a steady fill light next to a controlled one on a 3-pole splitter branch, where the fill light needs power only.
Selection notes
This adapter suits 2-pole VCB lights. A light with a 3-pole VCC plug needs a path that carries Control, so use a 3-pole cable or splitter instead.
Check the genders: the VCC male end plugs into a female 3-pole outlet and the VCB female end takes a male 2-pole plug on the light.
Any off-time between inspections has to come from the supply, since the Control line is not passed on. Choose a 3-pole light if the light must switch with the process.
Specifications: General
Brand
DCM Sistemes
Cable type
Lighting interconnection / adapter cable
Specifications: Interface
Connector A
VCC 3-pole male
Connector B
VCB 2-pole female
Specifications: Mechanical
Cable length
30 cm / 50 cm / 1 m / 1.5 m (longer than 150 cm on request)