Skip to content
Lumher PDX-850nm machine vision lighting
  • Rosepetal compatible
  • Recommended by AIS Vision

Lumher PDX Infrared 850nm

PDX-850nm

Lumher PDX-850nm linear LED luminaire: Infrared 850 nm, 24 Vdc ±5%, IP40 or IP65 (order option), mode Continuous (1x) / Strobe (4x), 15 sizes (Length L1 120–1,380 mm, Length L2 138–1,398 mm), beam Semidiffuse 60° / Ultradiffuse 110°.

Brand
Lumher
Lighting type
Bar / linear (Linear series)
Color / wavelength
Infrared 850nm
Available wavelengths
Infrared 850 nm
Emission angle
Semidiffuse 60° / Ultradiffuse 110°
Diffuser
Yes (Polycarbonate)
Mode
Continuous (1x) / Strobe (4x)
Driver technology
Integrated controller
Supply voltage
24 Vdc ±5%
IP rating
IP40 or IP65 (order option)
Connection
M12A, 2m cable, M12A connector with cable
Housing material
Anodized aluminum

Technical overview

The Lumher PDX-850nm is a linear LED luminaire from the PDX series that emits infrared light at 850 nm, outside the visible range. It suits imaging where visible ambient light needs to stay out of the image. The manufacturer describes the PDX as a high-performance, stringable luminaire, with up to 47 modules of 90 mm depending on the operating mode. The series has 15 sizes, PDX 01 to PDX 15, with a length L1 of 120–1,380 mm and a length L2 of 138–1,398 mm.

The beam is listed as Semidiffuse 60° / Ultradiffuse 110°. Operating modes are Continuous (1x) and Strobe (4x), so the same bar supports both steady and pulsed operation. Control is by an integrated controller on a 24 Vdc ±5% supply, and the connection is M12A with a 2 m cable and an M12A connector with cable.

The housing is anodized aluminum, the enclosure is IP40 or IP65 chosen at order, and the operating temperature range is -10°C to +40°C. For installation, the bar length and the 2 m cable length should be planned together, so the luminaire sits within cable reach of its M12A connection while still covering the full imaged width.

Best for

  • Infrared linear illumination at 850 nm where visible ambient light must be kept out of the image.
  • Long linear layouts built from stringable modules, up to 47 of 90 mm depending on the operating mode.
  • Pulsed imaging of moving parts with the Strobe (4x) mode.
  • Installations on a 24 Vdc supply with an integrated controller.
  • Environments that need IP65 protection, selected at order.

Selection notes

  • Set the enclosure rating when ordering: IP40 or IP65 is an order option.
  • Plan the module count and the operating mode together, since the up to 47 modules of 90 mm figure depends on the mode.
  • Choose the PDX size whose length covers the imaged width, across PDX 01 to PDX 15.
  • Keep the installation within -10°C to +40°C and supply 24 Vdc ±5%.
  • For Strobe (4x) operation, check the trigger and I/O details in the manufacturer datasheet before wiring the pulsed signal.

Specifications: General
BrandLumher
Lighting typeBar / linear (Linear series)

Specifications: Interface
ConnectionM12A, 2m cable, M12A connector with cable

Specifications: Optical
Color / wavelengthInfrared 850nm
Available wavelengthsInfrared 850 nm
Emission angleSemidiffuse 60° / Ultradiffuse 110°
DiffuserYes (Polycarbonate)

Specifications: Electrical
ModeContinuous (1x) / Strobe (4x)
Driver technologyIntegrated controller
Supply voltage24 Vdc ±5%

Specifications: Environment
IP ratingIP40 or IP65 (order option)
Operating temperature-10°C to +40°C

Specifications: Mechanical
Housing materialAnodized aluminum
DimensionsLength L1 120–1,380 mm, Length L2 138–1,398 mm (15 sizes: PDX 01 … PDX 15)

Frequently asked questions

Related technical guides

Often used with

Lighting controllers

Strobe and intensity control for stable, repeatable illumination.

All lighting controllers →
  • DCM Sistemes VST11I machine vision lighting
    • Strobe (stroboscopic) drive mode
    • This is the controller itself (drives external strobe lighting)
    • 24 VDC
    • Terminal block
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Omron / Sentech FLV-TCC3HB machine vision lighting
    • Trigger (strobe) and continuous lighting
    • IP20 (IEC 60529)
    • Drive: 0ch constant-current, 1ch/2ch constant-voltage; PWM duty 100 kHz / voltage adjustment, 255 levels
    • Up to 15 W (24 V external trigger lighting; 12 V continuous up to 7.5 W)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Basler Light Controller 2C-1.25A-50W-24V machine vision lighting
    • Current-controlled
    • 100–240 VAC input / 8–24 VDC output
    • 50 W (total output)
    • 0–40 °C
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • DCM Sistemes VSC3100B machine vision lighting
    • RGB (drives RGB / mixed colour lighting via 3 channels)
    • Strobe (stroboscopic) drive mode, per-shot current regulation
    • This is the controller itself (drives external strobe/RGB lighting)
    • +24 VDC ±3%
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Lighting cables

Industrial Lighting cables with locking connectors. Check length and flex rating against your installation.

All cables →
  • Lumher PD-850nm machine vision lighting
    • Bar / linear (Linear series)
    • Infrared 850nm
    • Continuous (1x) / Strobe (4x)
    • Semidiffuse 60° / Ultradiffuse 110°
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Lumher P2D-850nm machine vision lighting
    • Bar / linear (Parallel series)
    • Infrared 850nm
    • Continuous (1x) / Strobe (4x)
    • Semidiffuse 60° / Ultradiffuse 110°
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Rosepetal · AI

Test this camera with Rosepetal

Validate your visual inspection with AI: send us sample images and we evaluate the case on your hardware.

AIS Vision · Integration

We validate camera + lens + lighting

AIS Vision defines and tests the optimal combination of camera, optics and lighting for your application before you buy.