The Omron E6A2-C is a miniature incremental rotary encoder in a 25 mm diameter housing, from the E6A family. It has a 4 mm solid shaft and offers 60–500 PPR in five resolutions: 60, 100, 200, 360 and 500 PPR. The small body makes it suited to axes where space for an encoder is limited.
The output is NPN, and the order codes describe it as NPN open collector. Two supply ranges are given, 12-24 V and 5-12 V, depending on the variant, and the connection is a cable. The order codes show cable lengths of 0.5 m and 2 m, and some are described as 2-phase. Resolution, supply range and cable length are therefore chosen through the order code.
The general role of an incremental encoder in vision installations is to deliver a pulse train proportional to shaft rotation, which a controller can count to follow conveyor or roller travel or use to time image capture. With a resolution range of 60–500 PPR in a 25 mm housing, this encoder suits axes that need a small body and 60–500 pulses per revolution.
Best for
Small rollers and drive shafts with a 4 mm shaft where a 25 mm housing is needed
Conveyor feedback where 60–500 PPR is enough resolution
Systems with NPN-type inputs, using NPN open collector output
Machines using either a 12-24 V or a 5-12 V supply, depending on the variant
Selection notes
Pick the resolution from 60, 100, 200, 360 or 500 PPR; resolution, supply and cable length are ordered through separate codes.
The output is NPN (NPN open collector in the order codes); confirm that the receiving input suits an NPN output.
Choose the supply range, 12-24 V or 5-12 V, according to the variant, and check it against the supply on the machine.
The connection is a cable; the order codes show 0.5 m and 2 m lengths, and some codes are described as 2-phase.
The shaft is solid and 4 mm in diameter; plan a suitable coupling to the driven shaft.
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Availability
Encoder, incremental, 100ppr, 12-24 VDC, NPN open collector, 0.5 m cable Base
On request
Encoder, incremental, 100ppr, 12-24 VDC, NPN open collector, 2 m cable
On request
Encoder, incremental, 360ppr, 12-24 VDC, NPN open collector, 2 m cable
On request
Encoder, incremental, 60 ppr, 12 to 24 VDC, NPN open collector, 0.5 m cable
On request
Encoder, incremental, 60 ppr, 12 to 24 VDC, NPN open collector, 2 m cable
On request
Encoder, incremental, 200ppr, 5-12 VDC, NPN open collector, 0.5 m cable
On request
Encoder, incremental, 360 ppr, 5 to 12 VDC, 2-phase, NPN output, 2 m cable
On request
Encoder, incremental, 100ppr, 12-24 VDC, NPN open collector, 0.5m cable
On request
Encoder, incremental, 100ppr, 12-24 VDC, NPN open collector, 2m cable
These steps take an Omron Sentech (STC) camera from the box to a stable first image and on to your own application. They apply across the GigE Vision, USB3 Vision and CoaXPress STC families; the interface only changes how you cable and power the camera.
Download and install the Sentech SDK on the host PC. The package provides StViewer, the viewing and configuration software you use to bring the camera up, and StApi, the programming SDK you integrate later. Because the cameras are GenICam/GenTL-compliant, StApi also registers a GenTL producer, so any GenICam-compliant third-party vision software can discover and drive the camera as an alternative front end.
2. Cable, power and connect the camera
Connect according to the interface. GigE Vision: link to a Gigabit NIC (use PoE or the separate power input) and put the camera and host on the same subnet; for USB3 Vision use a USB 3.x port and a certified cable; for CoaXPress (STC) connect to a CoaXPress frame grabber, which also supplies Power-over-Coax. Then open StViewer and let it enumerate the camera. If a GigE camera does not appear, check the IP configuration and firewall, and on USB3 confirm the host bandwidth and driver.
3. Configure exposure, gain and white balance
Open the device in StViewer and start a live stream. Set exposure and gain for a well-exposed, low-noise image: raise exposure first and only add gain when more light or a faster shutter is not an option, keeping exposure short enough to freeze motion on global-shutter models. On colour cameras, run white balance under your actual production lighting. Adjust the lens aperture and focus on a representative target before tuning anything else.
4. Set the trigger and grab a first image
Start in free-run (continuous) acquisition to confirm a clean, stable image. For inline inspection switch to hardware or software triggering: select the trigger source, set the active edge and any delay, and wire the strobe or illumination to the camera's I/O so lighting fires with each exposure. Acquire and save a frame in StViewer; this saved image is your reference for the SDK stage and for downstream inspection.
5. Move to the StApi SDK (or any GenICam software)
Once the image is stable, reproduce the same settings in code. Use StApi to open the device, apply the GenICam features you validated in StViewer (exposure, gain, trigger, pixel format) and grab frames into your application via the bundled C++, C, C#/.NET or Python interfaces; the included samples are the fastest starting point. Prefer a different stack? The same GenICam/GenTL camera works with third-party vision libraries. With a reliable feed, you can route it into a deep-learning inspection such as Rosepetal for AI-based defect detection.
Frequently asked questions
60–500 PPR in five resolutions: 60, 100, 200, 360 and 500 PPR.
The housing diameter is 25 mm and the shaft is a solid shaft with a 4 mm diameter.
The output is NPN, and the supply is 12-24 V / 5-12 V depending on the variant.
It has a cable connection, with 0.5 m and 2 m cable lengths shown in the order codes.