- Ethernet cable
- 2 / 3 / 5 / 10 / 20 m
- M12
- FHV7 (listed on Omron's FHV7 model pages; description: "FHV7")
- Recommended by AIS Vision

V320-F 1.2 MP Plus Mode
Omron MicroHAWK V320-F 1.2 MP fixed-focus code reader, Plus Mode (1D/2D) decoder — 1.2 MP monochrome sensor; 42 fps; Fixed focus at 50 / 64 / 81 / 133 mm; 19–129 mm field-of-view width; lighting: Inner LEDs only; RS-232, USB (Ethernet over USB), digital I/O; IP40.
The 1.2 MP V320-F is the fine-detail version of the Plus Mode V320-F: fields run 19–129 mm over 1280 px, so each pixel covers 19 ÷ 1280 ≈ 0.015 mm at the narrowest and 129 ÷ 1280 ≈ 0.101 mm at the widest. Against the 0.3 MP V320-F, whose finest footprint is 34 ÷ 752 ≈ 0.045 mm, the narrowest field here is about three times finer (0.045 ÷ 0.015 ≈ 3.0).
| Brand | Omron |
|---|---|
| Reader type | Smart reader (Omron class "Fixed Mount AI-powered Smart Reader") |
| Form factor | Fixed-mount |
| Resolution | 1.2 MP (1280 × 960 px) |
|---|---|
| Horizontal resolution | 1280 px |
| FPS | 42 fps |
|---|
| Communication | RS-232, USB (Ethernet over USB), digital I/O |
|---|
| Focus | Fixed focus (factory-set focus distance per model) |
|---|---|
| Field of view | 19–129 mm field-of-view width (depends on view type and focus distance) |
| Integrated lighting | Inner LEDs only |
| IP rating | IP40 |
|---|
| Scan technology | 2D imager (global shutter, monochrome sensor) |
|---|---|
| Supported codes | 1D: PDF417, Micro PDF417, GS1 Databar (Composite and Stacked), Code 39, Code 128, BC412, Interleaved 2 of 5, UPC/EAN, Codabar, Code 93, Pharmacode; 2D: QR Code, Data Matrix (ECC200), Micro QR Code, Aztec Code, Dotcode; postal: PLANET, POSTNET, Japanese Postal, Australia Post, Royal Mail, Intelligent Mail, KIX |
| Read distance | Fixed focus at 50 / 64 / 81 / 133 mm (one focus distance per model) |
| Dimensions | 51.5 × 24.1 × 38.8 mm (W × H × D) |
|---|
How to size camera resolution from field of view and the smallest defect using the 3-5 px rule, plus why optics, lighting and bandwidth cap usable resolution.
A practical engineering guide to selecting image-based 1D, 2D and DPM code readers: how to match resolution and field of view to module size, set working distance and depth of field, pick DPM lighting and optics, and choose decode strategy, communication and grading.
How to choose laser or imager and fixed or handheld readers, and size conveyor and tunnel reading from belt speed, code density and depth of field.
Often used with
Industrial Ethernet / GigE cables with locking connectors. Check length and flex rating against your installation.




Industrial I/O and power cables with locking connectors. Check length and flex rating against your installation.




Brackets and protective housings to fix and protect the device on the line.







AIS Vision · Integration