Skip to content
Opto Engineering LTCLHP024-W machine vision lighting
  • Rosepetal compatible
  • Recommended by AIS Vision

Opto Engineering LTCLHP024-W (LTCLHP series)

LTCLHP024-W

Opto Engineering LTCLHP024-W telecentric illuminator — White, 6000 K, beam Ø 30 mm, WD 45–90 mm, 12-24 V, 2.5 W max, pulse current up to 2000 mA, M8 connector, length 124.7 mm, front diameter 44.0 mm, 279 g.

Brand
Opto Engineering
Lighting type
Telecentric (Telecentric lights)
Color / wavelength
White, 6000 K
Available wavelengths
White, 6000 K
Color temperature
6000 K
Working distance
45–90 mm
Illuminated area
Ø 30 mm (beam diameter)
Supply voltage
12-24 V (tolerance ± 10%)
Power consumption
2.5 W max
Mode
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Connection
M8
Dimensions
Length 124.7 mm, front diameter 44.0 mm — nominal value, with no spacers in place

Technical overview

The Opto Engineering LTCLHP024-W is a telecentric high-performance (HP) illuminator from the LTCLHP series. Its white output is specified at 6000 K, and the beam is listed at Ø 30 mm, which sets the illuminated area. Telecentric illumination emits collimated light, so the rays run nearly parallel across the working distance and the apparent size of a part changes less when its distance from the light varies. That is the property that makes telecentric lighting suited to edge and outline measurement.

The working distance is 45–90 mm, so the object should be held inside that band during inspection. Power is 2.5 W max from a 12-24 V (tolerance ± 10%) supply. The light mode is continuous or pulsed: pulse current can reach 2000 mA, while the maximum continuous LED current is 350 mA, and those two limits set how the driver is configured. Continuous operation within the 350 mA limit suits steady, fixed-position checks, while pulsed operation can reduce motion blur on moving parts, provided the controller respects the listed pulse rating. The unit connects through an M8 connector.

The listed length is 124.7 mm, the front diameter is 44.0 mm and the weight is 279 g. These are nominal values with no spacers in place, so the mounting envelope should be checked with any spacers fitted. The operating temperature range is 0–40 °C. The 124.7 mm length and 44.0 mm front diameter are the figures to plan around when fitting the unit into a fixture with limited room.

Best for

  • Dimensional checks on parts that fit inside the Ø 30 mm illuminated area, held at a 45–90 mm working distance
  • Edge and outline detection where the area of interest is within the Ø 30 mm beam
  • Presence checks on components within the Ø 30 mm illuminated area
  • Pulsed illumination of parts in motion, kept within the 2000 mA maximum pulse current
  • Inspection fixtures with limited mounting room, planned around the 124.7 mm length, 44.0 mm front diameter and 279 g weight

Selection notes

  • Size the camera's field of view to fit inside the Ø 30 mm beam, because the illuminated area sets the region that is lit.
  • Hold the object within the specified 45–90 mm working distance.
  • For pulsed operation, keep pulse current at or below 2000 mA and continuous drive at or below the 350 mA maximum LED current, and set the controller limits before connecting the unit.
  • Power the unit from 12-24 V (tolerance ± 10%) with a supply sized for the 2.5 W maximum draw, and operate it within 0–40 °C.
  • Check the M8 pinout and any pulse-control wiring in the manufacturer datasheet before connecting a strobe controller.

Specifications: General
BrandOpto Engineering
Lighting typeTelecentric (Telecentric lights)

Specifications: Interface
ConnectionM8

Specifications: Optical
Color / wavelengthWhite, 6000 K
Available wavelengthsWhite, 6000 K
Color temperature6000 K
Working distance45–90 mm

Specifications: Electrical
Supply voltage12-24 V (tolerance ± 10%)
Power consumption2.5 W max
ModeContinuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)

Specifications: Environment
Operating temperature0–40 °C

Specifications: Geometry
Illuminated areaØ 30 mm (beam diameter)

Specifications: Mechanical
DimensionsLength 124.7 mm, front diameter 44.0 mm — nominal value, with no spacers in place
Weight279 g

Frequently asked questions

Related technical guides

Often used with

Lighting controllers

Strobe and intensity control for stable, repeatable illumination.

All lighting controllers →
  • DCM Sistemes VST11I machine vision lighting
    • Strobe (stroboscopic) drive mode
    • This is the controller itself (drives external strobe lighting)
    • 24 VDC
    • Terminal block
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Omron / Sentech FLV-TCC3HB machine vision lighting
    • Trigger (strobe) and continuous lighting
    • IP20 (IEC 60529)
    • Drive: 0ch constant-current, 1ch/2ch constant-voltage; PWM duty 100 kHz / voltage adjustment, 255 levels
    • Up to 15 W (24 V external trigger lighting; 12 V continuous up to 7.5 W)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Basler Light Controller 2C-1.25A-50W-24V machine vision lighting
    • Current-controlled
    • 100–240 VAC input / 8–24 VDC output
    • 50 W (total output)
    • 0–40 °C
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • DCM Sistemes VSC3100B machine vision lighting
    • RGB (drives RGB / mixed colour lighting via 3 channels)
    • Strobe (stroboscopic) drive mode, per-shot current regulation
    • This is the controller itself (drives external strobe/RGB lighting)
    • +24 VDC ±3%
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Lighting cables

Industrial Lighting cables with locking connectors. Check length and flex rating against your installation.

All cables →
  • Opto Engineering LTCLHP016-W machine vision lighting
    • Telecentric (Telecentric lights)
    • White, 6000 K
    • Ø 20 mm (beam diameter)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Opto Engineering LTCLHP023-W machine vision lighting
    • Telecentric (Telecentric lights)
    • White, 6000 K
    • Ø 16 mm (beam diameter)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Opto Engineering LTCLHP036-W machine vision lighting
    • Telecentric (Telecentric lights)
    • White, 6000 K
    • Ø 45 mm (beam diameter)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Rosepetal · AI

Test this camera with Rosepetal

Validate your visual inspection with AI: send us sample images and we evaluate the case on your hardware.

AIS Vision · Integration

We validate camera + lens + lighting

AIS Vision defines and tests the optimal combination of camera, optics and lighting for your application before you buy.