The VCU01A lets several PLD and PLU lights share one power-supply cable run. Both ends are female VCB 2-pole connectors wired straight through, +VDC pin 1 to pin 1 and GND pin 2 to pin 2, so polarity is kept. It comes in 30 cm, 50 cm, 1 m and 1.5 m (order codes VCU01A003, 005, 010 and 015), longer on request, and the length sets the spacing between neighbouring lights.
Sharing a run loads the supply cable with the total current. As an example, three lights drawing 1 A each put 3 A on the first section, against the 5 A rating at 30 °C of the VCB power cable, and the voltage drop grows with every metre between the supply and the last light, so keep the chain short. The cable passes power straight through and adds no switching or control. Check its current rating against the combined draw before chaining several amps through it.
Best for
PLD and PLU light arrays where several units are fed from one supply cable run instead of a separate home run to each light.
Adding a light next to an existing one: a 30 cm or 50 cm link reaches the neighbour without new wiring back to the cabinet.
Arrays with regular spacing up to 1.5 m, where the four stock lengths cover common spacings without a made-to-order cable.
Selection notes
Choose the length from the spacing between lights, with enough slack that the cable is not under tension.
Add up the current of all lights in the chain and check the supply cable and the voltage drop against it.
It connects the PLD and PLU series; for other lights ask us. Cables longer than 150 cm are made on request.
Specifications: General
Brand
DCM Sistemes
Cable type
Lighting interconnection / adapter cable
Compatible with
DCM Sistemes PLD and PLU series
Specifications: Interface
Connector A
VCB 2-pole female
Connector B
VCB 2-pole female
Specifications: Mechanical
Cable length
30 cm / 50 cm / 1 m / 1.5 m (longer than 150 cm on request)