iRAYPLE C03-GE-RJ45-RJ45-FC — Gigabit Ethernet cable (RJ45 to RJ45); End A RJ45 (with locking stud), End B RJ45; lengths 3–30 m (3, 5, 7, 10, 15, 20, 30 m); structure 26AWG*4P+NON WOVEN FABRIC+B; Ø 6.5 mm; PVC jacket; min. bending radius 60 mm; drag-chain rated (10 million cycles); operating -20 °C to +80 °C.
Brand
iRAYPLE
Cable type
Gigabit Ethernet cable (RJ45 to RJ45)
Cable length
3–30 m (3, 5, 7, 10, 15, 20, 30 m)
Connector A
RJ45 (with locking stud)
Connector B
RJ45
High-flex / drag chain
Yes — dynamic scene (drag chain), 10 million cycles
Compatible with
GigE industrial cameras (RJ45 with locking screws)
Flexing is the point of this GigE cable: four 26 AWG pairs in a 6.5 mm PVC jacket, rated for 10 million drag-chain cycles. Compared with the static C01/C03-GE-RJ45-RJ45 (6.3 mm, 70 mm radius), the jacket is 0.2 mm thicker and the minimum bending radius drops to 60 mm.
Choose from 3, 5, 7, 10, 15, 20 and 30 m. Clamp both ends of the chain run so the plugs never carry the load, with the locking-stud End A on the camera, and keep the chain's inner radius at or above 60 mm. The maximum operating voltage is 30 VDC, below the roughly 48 V of PoE, so confirm with us before powering a moving camera over this cable.
Best for
GigE cameras on moving axes such as scanner gantries, pick-and-place heads or sliding stages, with the cable in a chain.
Short moving runs of 3 m, below the 5 m minimum of the static version.
Tight chains, since the 60 mm minimum bending radius is 10 mm smaller than the 70 mm of the static cable.
Selection notes
Past 30 m, a moving camera has no cable of this kind: put a switch near the axis and run the long section as static C01/C03-GE-RJ45-RJ45, which goes to 70 m.
This cable's certification is RoHS2.0; the static C01/C03-GE-RJ45-RJ45 also carries UL, so confirm with us if your project requires UL on a moving cable.
Confirm the camera has an RJ45 with locking screws, the port the stud on End A mates with.
Specifications: General
Brand
iRAYPLE
Cable type
Gigabit Ethernet cable (RJ45 to RJ45)
Compatible with
GigE industrial cameras (RJ45 with locking screws)
Specifications: Interface
Connector A
RJ45 (with locking stud)
Connector B
RJ45
Specifications: Electrical
Supply voltage
30 VDC
Specifications: Environment
Operating temperature
-20 °C to +80 °C
Specifications: Mechanical
Cable length
3–30 m (3, 5, 7, 10, 15, 20, 30 m)
High-flex / drag chain
Yes — dynamic scene (drag chain), 10 million cycles
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
This is a Gigabit Ethernet cable. For 10GigE cameras the drag-chain option is C01-10GE-RJ45-RJ45-FC.
10 million drag-chain cycles, with connectors rated for ≥750 mating cycles.