Against the R3013MG/U-05H, which has the same 0.05 mm (1D) and 0.08 mm (2D) minimum modules over the same 40–150 mm, this model moves to 1440 × 1080 px behind a 6.72 mm lens in a smaller, sealed body: 45 × 35 × 25.5 mm, under 110 g and IP65. The field runs from 30 × 22 mm at 40 mm to 111 × 83 mm at 150 mm, which is 30 mm ÷ 1440 ≈ 0.021 mm per pixel near and 111 mm ÷ 1440 ≈ 0.077 mm per pixel far. The minimums therefore hold only at the near end (0.05 mm is about 2.4 px, 0.08 mm about 3.8 px); at 150 mm a 0.08 mm module is only about 1 px.
Built-in AI code-reading algorithms with multi-parameter polling are aimed at complex applications, and the supported codes include Data Matrix ECC 000–140, QR Model 1 and PDF417. Code-quality evaluation to ISO/IEC 15415, 15416 and 29158 is offered; use it to monitor print quality rather than as a replacement for a calibrated verifier.
Best for
Compact cells that need a sealed reader: IP65 in a 45 × 35 × 25.5 mm body that weighs under 110 g.
Older or less common marks, since Data Matrix ECC 000–140 and QR Model 1 are among the supported codes.
Moving products, with 50 codes/s decoding and a 3 m/s object-speed rating.
Selection notes
The communication link is 100M Ethernet with PROFINET, EtherNet/IP, Modbus, MC (SLMP) and FINS; for a USB version, look at the R3013MG/U-05H.
For modules below 0.08 mm, the R3016PMG-16H is rated down to 0.027 mm (2D) over 80–200 mm, with a smaller field of 21 × 16 to 58 × 44 mm.
Two order codes exist, with red or white light; choose by testing label contrast on your material. Supply is 9–26 V DC at under 9.5 W or 10.5 W depending on order code, so budget about 10.5 W per reader.
Specifications: General
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
AI / deep learning
Built-in AI code reading algorithms and multi-parameters polling to ensure effects of complex applications
Specifications: Sensor
Resolution
1.6 MP (1440 × 1080)
Horizontal resolution
1440 px
Specifications: Performance
FPS
60 fps
Specifications: Interface
Communication
100M Ethernet; protocols: SDK, TCP Client, TCP Server, FTP, RS232, Profinet, Modbus, EtherNet/IP, MC (SLMP), FINS/UDP, FINS/TCP
Connection
Industrial-grade M12 connectors are Ethernet and GPIO interfaces
Specifications: Optical
Field of view
30 × 22 mm – 111 × 83 mm
Focal length
6.72 mm
Focus
Manual focus
Integrated lighting
Red · White — depending on order code
Illumination colour
Red · White — depending on order code
Specifications: Electrical
Supply voltage
9–26VDC, 1A input
Power consumption
<9.5 W (R3016PMG-07H-RGF01E) · <10.5 W (R3016PMG-07H-WGN01E)
Specifications: Environment
IP rating
IP65
Operating temperature
-20 °C to +50 °C
Specifications: Reading
Scan technology
2D area imager (global shutter)
Supported codes
1D: Code 39/Code 93/Code128/CodaBar/EAN8/EAN13/UPCA/UPCE/ITF25/2of5 (Industrial2of5)etc. and 2D: QR/Data Matrix/MQR/GS1 DM/GS1QR/PDF417/QRModel1/DMECC000-140 etc.
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Integrated lighting ●
Illumination colour ●
Power consumption ●
Availability
red light Base
Red
Red
<9.5 W
On request
white light
White
White
<10.5 W
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
It is rated IP65 and operates from -20 to +50 °C.
The rating is up to 3 m/s, with decoding up to 50 codes/s. At 3 m/s a part moves 0.021 mm, one near-end pixel, in about 7 µs (0.021 mm ÷ 3000 mm/s), so exposure must be very short to stay sharp, and a code crosses the 30 mm near-end field in about 10 ms, less than one 60 fps frame (about 17 ms): time the capture to the part.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE