The 12 mm lens halves the field of the R5016MG-06M: 85 × 64 mm at 200 mm against 170 × 127 mm, so sampling improves from 0.118 mm to 85 mm ÷ 1440 px ≈ 0.059 mm per pixel. The minimum modules of 0.04 mm (1D) and 0.06 mm (2D) are specified for the red-light and white-light versions and can only hold near the 80 mm end, where the field is about 34 mm (85 mm × 80 ÷ 200) and a pixel covers 0.024 mm, so a 0.06 mm module spans about 2.5 px (0.06 ÷ 0.024). At the 1500 mm far end the field is about 638 mm (85 mm × 1500 ÷ 200) and a pixel covers 638 mm ÷ 1440 px ≈ 0.44 mm, so 2 px per module means modules of about 0.9 mm.
Blue, red and white lighting are offered by order code; blue darkens red print, so it helps on red-on-white labels. The reader runs built-in deep-learning algorithms with multi-parameter polling aimed at complex applications, takes 9–26 V DC at 2 A, uses GigE and decodes up to 90 codes/s.
Best for
Mixed work where autofocus moves from 80 mm to 1500 mm without any manual setup, with 0.06 mm 2D modules near 80 mm and about 0.9 mm modules at 1500 mm.
Red-printed labels under the blue-light version, which darkens red ink against a white background.
Fast conveyors rated up to 3 m/s: a pixel at 200 mm is 0.059 mm, crossed in about 20 µs (0.059 mm ÷ 3000 mm/s), so keep exposure short.
Selection notes
The 0.04 mm and 0.06 mm minimums are specified for the red and white versions; for the blue version, test your smallest code before committing.
Wider coverage comes from the R5016MG-06M, which sees 170 × 127 mm at 200 mm.
GigE cabling typically reaches 100 m on copper, so the reader can sit far from the PLC cabinet.
Specifications: General
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
AI / deep learning
Built-in deep-learning algorithms and multi-parameters polling to ensure effects of complex applications
1D code 0.04 mm / 2D code 0.06 mm (stated for red light / white light)
Specifications: Mechanical
Dimensions
82 × 55 × 53 mm (not including connector)
Weight
<350 g
Housing material
Aluminum alloy + Front cover
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Integrated lighting ●
Illumination colour ●
Min. code resolution ●
Availability
blue light Base
Blue, Polarized/Non-polarized
Blue, Polarized/Non-polarized
—
On request
red light
Red, Polarized/Non-polarized
Red, Polarized/Non-polarized
1D code 0.04 mm / 2D code 0.06 mm
On request
white light
White
White
1D code 0.04 mm / 2D code 0.06 mm
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
85 × 64 mm, against 170 × 127 mm on the R5016MG-06M. Both fields scale roughly in proportion to working distance.
The blue-light version, because blue light darkens red print and raises contrast on a white background.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE