LTCLCR096-B

Opto Engineering LTCLCR096-B telecentric illuminator — Blue, 460 nm, beam Ø = 120, x = 99 mm, WD 200–350 mm, 12-24 V, 2.5 W max, pulse current up to 2000 mA, M8 connector, A 139.0 mm, B 171.9 mm, C 182.9 mm (A/B/C), 4142 g.

Brand
Opto Engineering
Lighting type
Telecentric (Telecentric lights)
Color / wavelength
Blue, 460 nm
Available wavelengths
Blue, 460 nm
Working distance
200–350 mm
Illuminated area
Ø = 120, x = 99 mm (minimum beam shape dimension; beam shape is not circular)
Supply voltage
12-24 V (tolerance ± 10%)
Power consumption
2.5 W max
Mode
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Connection
M8
Dimensions
A 139.0 mm, B 171.9 mm, C 182.9 mm (dimensions A/B/C as on the maker’s drawing) — nominal value, with no spacers in place
Weight
4142 g

Technical overview

The LTCLCR096-B is a blue telecentric illuminator with a 460 nm output, part of the LTCLHP CORE series of compact telecentric illuminators. Telecentric illumination emits near-parallel (collimated) light. Paired with a telecentric lens, it helps keep a feature's apparent size and position stable over small changes in distance, which is the basis for telecentric gauging. The listed working distance of 200–350 mm sets the stand-off band, and the lit area is given as Ø = 120, x = 99 mm. That beam is not circular, with x = 99 mm as the minimum beam-shape dimension, so the footprint of the feature should be checked against the beam shape as well as its diameter. The single 460 nm wavelength places the output in the blue part of the visible spectrum, where the choice of color can change how a feature contrasts with its surroundings.

The electrical interface is a 12–24 V supply with a ±10% tolerance, a 2.5 W max power draw, and an M8 connector. Light mode is continuous or pulsed. Continuous LED current is capped at 350 mA, and pulse current can reach up to 2000 mA, so the controller must keep steady and pulsed operation inside their separate limits. The operating temperature range is 0–40 °C, which should be the design ambient for the enclosure.

The listed dimensions are A 139.0 mm, B 171.9 mm and C 182.9 mm, as given on the maker's drawing and nominal with no spacers in place. The head weighs 4142 g, so the bracket and stand must carry a substantial static load, and a repeatable stand-off mount helps keep the 200–350 mm working distance constant from part to part. Because the output is a single 460 nm wavelength, the camera and lens chosen to pair with it should be checked for sensitivity at that wavelength.

Best for

  • Silhouette and edge gauging of parts placed 200–350 mm from the lens.
  • Position and diameter checks on components that fit within the Ø = 120, x = 99 mm beam.
  • Blue-light telecentric inspection where a 460 nm output is the chosen wavelength.
  • Measurement cells with a fixed stand-off band, where a rigid mount holds the 200–350 mm working distance.

Selection notes

  • Fix the part and lens within the 200–350 mm working distance, and keep that stand-off repeatable from part to part.
  • Verify that the non-circular Ø = 120, x = 99 mm beam covers the feature footprint with margin.
  • Power the head from 12–24 V with ±10% tolerance, budgeting 2.5 W max, and keep continuous LED current at or below 350 mA.
  • Mount to the nominal A 139.0 mm, B 171.9 mm and C 182.9 mm envelope (no spacers in place) and support the 4142 g mass on a rigid bracket.
  • Confirm in the manufacturer datasheet how pulsed mode is triggered and wired through the M8 connector.

Specifications: General
BrandOpto Engineering
Lighting typeTelecentric (Telecentric lights)

Specifications: Interface
ConnectionM8

Specifications: Optical
Color / wavelengthBlue, 460 nm
Available wavelengthsBlue, 460 nm
Working distance200–350 mm

Specifications: Electrical
Supply voltage12-24 V (tolerance ± 10%)
Power consumption2.5 W max
ModeContinuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)

Specifications: Environment
Operating temperature0–40 °C

Specifications: Geometry
Illuminated areaØ = 120, x = 99 mm (minimum beam shape dimension; beam shape is not circular)

Specifications: Mechanical
DimensionsA 139.0 mm, B 171.9 mm, C 182.9 mm (dimensions A/B/C as on the maker’s drawing) — nominal value, with no spacers in place
Weight4142 g

Frequently asked questions

Related technical guides

Often used with

Lighting controllers

Strobe and intensity control for stable, repeatable illumination.

All lighting controllers →
  • DCM Sistemes VST11I machine vision lighting
    • Strobe (stroboscopic) drive mode
    • This is the controller itself (drives external strobe lighting)
    • 24 VDC
    • Terminal block
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Omron / Sentech FLV-TCC3HB machine vision lighting
    • Trigger (strobe) and continuous lighting
    • IP20 (IEC 60529)
    • Drive: 0ch constant-current, 1ch/2ch constant-voltage; PWM duty 100 kHz / voltage adjustment, 255 levels
    • Up to 15 W (24 V external trigger lighting; 12 V continuous up to 7.5 W)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Basler Light Controller 2C-1.25A-50W-24V machine vision lighting
    • Current-controlled
    • 100–240 VAC input / 8–24 VDC output
    • 50 W (total output)
    • 0–40 °C
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • DCM Sistemes VSC3100B machine vision lighting
    • RGB (drives RGB / mixed colour lighting via 3 channels)
    • Strobe (stroboscopic) drive mode, per-shot current regulation
    • This is the controller itself (drives external strobe/RGB lighting)
    • +24 VDC ±3%
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Lighting cables

Industrial Lighting cables with locking connectors. Check length and flex rating against your installation.

All cables →
  • Opto Engineering LTCLCR064-B machine vision lighting
    • Telecentric (Telecentric lights)
    • Blue, 460 nm
    • Ø = 86, x = 67 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Opto Engineering LTCLCR080-B machine vision lighting
    • Telecentric (Telecentric lights)
    • Blue, 460 nm
    • Ø = 98, x = 90 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Opto Engineering LTCLCR120-B machine vision lighting
    • Telecentric (Telecentric lights)
    • Blue, 460 nm
    • Ø = 156, x = 130 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Rosepetal · AI

Test this camera with Rosepetal

Validate your visual inspection with AI: send us sample images and we evaluate the case on your hardware.

AIS Vision · Integration

We validate camera + lens + lighting

AIS Vision defines and tests the optimal combination of camera, optics and lighting for your application before you buy.