Skip to content
Opto Engineering LTCLCR120-B machine vision lighting
  • Rosepetal compatible
  • Recommended by AIS Vision

Opto Engineering LTCLCR120-B (LTCLHP CORE series)

LTCLCR120-B

Opto Engineering LTCLCR120-B telecentric illuminator — Blue, 460 nm, beam Ø = 156, x = 130 mm, WD 220–440 mm, 12-24 V, 2.5 W max, pulse current up to 2000 mA, M8 connector, A 181.4 mm, B 220.0 mm, C 230.6 mm (A/B/C), 9020 g.

Brand
Opto Engineering
Lighting type
Telecentric (Telecentric lights)
Color / wavelength
Blue, 460 nm
Available wavelengths
Blue, 460 nm
Working distance
220–440 mm
Illuminated area
Ø = 156, x = 130 mm (minimum beam shape dimension; beam shape is not circular)
Supply voltage
12-24 V (tolerance ± 10%)
Power consumption
2.5 W max
Mode
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Connection
M8
Dimensions
A 181.4 mm, B 220.0 mm, C 230.6 mm (dimensions A/B/C as on the maker’s drawing) — nominal value, with no spacers in place
Weight
9020 g

Technical overview

The LTCLCR120-B is a blue telecentric illuminator with a 460 nm output, part of the LTCLHP CORE series of compact telecentric illuminators. Telecentric illumination emits near-parallel (collimated) light, and paired with a telecentric lens it helps keep a feature's apparent size and position stable over small changes in distance. The listed working distance of 220–440 mm sets the stand-off band in which the part and lens can be placed. The lit area is given as Ø = 156, x = 130 mm; the beam is not circular, with x = 130 mm as the minimum beam-shape dimension, so the footprint should be checked against both values. The single 460 nm wavelength places the output in the blue part of the visible spectrum, where the choice of color can change how a feature contrasts with its surroundings.

The electrical interface is a 12–24 V supply with a ±10% tolerance, a 2.5 W max power draw, and an M8 connector. Light mode is continuous or pulsed. Continuous LED current is capped at 350 mA, while pulse current reaches up to 2000 mA, so the controller must keep steady and pulsed operation inside their separate limits. The operating temperature range is 0–40 °C.

The listed dimensions are A 181.4 mm, B 220.0 mm and C 230.6 mm, as given on the maker's drawing and nominal with no spacers in place. The head weighs 9020 g, so it needs a rigid, heavy-duty stand or bracket, and a repeatable mount helps the working distance hold from part to part. Because the output is a single 460 nm wavelength, check the camera and lens sensitivity at that wavelength when specifying the imaging side.

Best for

  • Silhouette and edge gauging of parts placed 220–440 mm from a telecentric lens.
  • Position and diameter checks within the Ø = 156, x = 130 mm beam.
  • Blue-light telecentric inspection where a 460 nm output is the chosen wavelength.
  • Fixtures where the 9020 g head is carried on a rigid, heavy-duty bracket.

Selection notes

  • Set the part and lens within the 220–440 mm working distance and keep that stand-off repeatable.
  • Check that the non-circular Ø = 156, x = 130 mm beam covers the feature footprint with margin.
  • Budget a 12–24 V supply with ±10% tolerance for the 2.5 W max draw, and keep continuous LED current at or below 350 mA.
  • Mount to the nominal A 181.4 mm, B 220.0 mm and C 230.6 mm envelope (no spacers in place) and support the 9020 g mass on a rigid bracket.
  • Confirm in the manufacturer datasheet how pulsed mode is triggered and wired through the M8 connector.

Specifications: General
BrandOpto Engineering
Lighting typeTelecentric (Telecentric lights)

Specifications: Interface
ConnectionM8

Specifications: Optical
Color / wavelengthBlue, 460 nm
Available wavelengthsBlue, 460 nm
Working distance220–440 mm

Specifications: Electrical
Supply voltage12-24 V (tolerance ± 10%)
Power consumption2.5 W max
ModeContinuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)

Specifications: Environment
Operating temperature0–40 °C

Specifications: Geometry
Illuminated areaØ = 156, x = 130 mm (minimum beam shape dimension; beam shape is not circular)

Specifications: Mechanical
DimensionsA 181.4 mm, B 220.0 mm, C 230.6 mm (dimensions A/B/C as on the maker’s drawing) — nominal value, with no spacers in place
Weight9020 g

Frequently asked questions

Related technical guides

Often used with

Lighting controllers

Strobe and intensity control for stable, repeatable illumination.

All lighting controllers →
  • DCM Sistemes VST11I machine vision lighting
    • Strobe (stroboscopic) drive mode
    • This is the controller itself (drives external strobe lighting)
    • 24 VDC
    • Terminal block
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Omron / Sentech FLV-TCC3HB machine vision lighting
    • Trigger (strobe) and continuous lighting
    • IP20 (IEC 60529)
    • Drive: 0ch constant-current, 1ch/2ch constant-voltage; PWM duty 100 kHz / voltage adjustment, 255 levels
    • Up to 15 W (24 V external trigger lighting; 12 V continuous up to 7.5 W)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Basler Light Controller 2C-1.25A-50W-24V machine vision lighting
    • Current-controlled
    • 100–240 VAC input / 8–24 VDC output
    • 50 W (total output)
    • 0–40 °C
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • DCM Sistemes VSC3100B machine vision lighting
    • RGB (drives RGB / mixed colour lighting via 3 channels)
    • Strobe (stroboscopic) drive mode, per-shot current regulation
    • This is the controller itself (drives external strobe/RGB lighting)
    • +24 VDC ±3%
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Lighting cables

Industrial Lighting cables with locking connectors. Check length and flex rating against your installation.

All cables →
  • Opto Engineering LTCLCR064-B machine vision lighting
    • Telecentric (Telecentric lights)
    • Blue, 460 nm
    • Ø = 86, x = 67 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Opto Engineering LTCLCR080-B machine vision lighting
    • Telecentric (Telecentric lights)
    • Blue, 460 nm
    • Ø = 98, x = 90 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Opto Engineering LTCLCR096-B machine vision lighting
    • Telecentric (Telecentric lights)
    • Blue, 460 nm
    • Ø = 120, x = 99 mm (minimum beam shape dimension; beam shape is not circular)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Rosepetal · AI

Test this camera with Rosepetal

Validate your visual inspection with AI: send us sample images and we evaluate the case on your hardware.

AIS Vision · Integration

We validate camera + lens + lighting

AIS Vision defines and tests the optimal combination of camera, optics and lighting for your application before you buy.