Skip to content
Opto Engineering LTCLHP056-W machine vision lighting
  • Rosepetal compatible
  • Recommended by AIS Vision

Opto Engineering LTCLHP056-W (LTCLHP series)

LTCLHP056-W

Opto Engineering LTCLHP056-W telecentric illuminator — White, 6000 K, beam Ø 70 mm, WD 100–200 mm, 12-24 V, 2.5 W max, pulse current up to 2000 mA, M8 connector, length 210.5 mm, front diameter 80.0 mm, 806 g.

Brand
Opto Engineering
Lighting type
Telecentric (Telecentric lights)
Color / wavelength
White, 6000 K
Available wavelengths
White, 6000 K
Color temperature
6000 K
Working distance
100–200 mm
Illuminated area
Ø 70 mm (beam diameter)
Supply voltage
12-24 V (tolerance ± 10%)
Power consumption
2.5 W max
Mode
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Connection
M8
Dimensions
Length 210.5 mm, front diameter 80.0 mm — nominal value, with no spacers in place

Technical overview

The Opto Engineering LTCLHP056-W is a telecentric high-performance illuminator from the LTCLHP series, with a white output at 6000 K over a Ø 70 mm beam. The telecentric light type collimates the output, so the rays run close to parallel across the 100–200 mm working distance. For an installer this means a backlit silhouette that stays consistent when the part or camera shifts slightly, which is the main reason to choose a telecentric backlight for edge and outline work. Parts that fit inside the 70 mm beam and sit within that working distance band are the intended targets.

A 6000 K white output makes a general-purpose backlight choice when the aim is a clean silhouette and the part's color is not the contrast mechanism being measured. The unit runs from 12-24 V (tolerance ± 10%) at 2.5 W max. Continuous LED current is limited to 350 mA, while pulsed operation allows a maximum pulse current of 2000 mA, so the drive should be configured for whichever mode the application uses.

The body is 210.5 mm long with an 80.0 mm front diameter (nominal value, with no spacers in place) and weighs 806 g. It uses an M8 connector and operates from 0–40 °C. Fix the mounting position and cable route with those figures in mind before commissioning.

Best for

  • General silhouette and outline inspection of parts within the Ø 70 mm beam, where a neutral white backlight is preferred.
  • Presence and absence checks on molded, stamped or machined parts.
  • Pulsed backlighting for parts moving past the camera.
  • Fixed-standoff gauging stations with a working distance of 100–200 mm.
  • Backlighting where part color is not the feature under test.

Selection notes

  • Center the feature of interest in the Ø 70 mm beam and keep the part within the 100–200 mm working distance.
  • Check the drive against the 350 mA continuous limit and the 2000 mA maximum pulse current before setting up pulsed operation.
  • Plan supply capacity for 12-24 V (tolerance ± 10%) and a 2.5 W max draw.
  • Allow for the 806 g body and 210.5 mm length (nominal, with no spacers in place) in the mechanical design, and keep the ambient within 0–40 °C.
  • Confirm trigger and I/O wiring in the manufacturer datasheet before designing the controller interface.

Specifications: General
BrandOpto Engineering
Lighting typeTelecentric (Telecentric lights)

Specifications: Interface
ConnectionM8

Specifications: Optical
Color / wavelengthWhite, 6000 K
Available wavelengthsWhite, 6000 K
Color temperature6000 K
Working distance100–200 mm

Specifications: Electrical
Supply voltage12-24 V (tolerance ± 10%)
Power consumption2.5 W max
ModeContinuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)

Specifications: Environment
Operating temperature0–40 °C

Specifications: Geometry
Illuminated areaØ 70 mm (beam diameter)

Specifications: Mechanical
DimensionsLength 210.5 mm, front diameter 80.0 mm — nominal value, with no spacers in place
Weight806 g

Frequently asked questions

Related technical guides

Often used with

Lighting controllers

Strobe and intensity control for stable, repeatable illumination.

All lighting controllers →
  • DCM Sistemes VST11I machine vision lighting
    • Strobe (stroboscopic) drive mode
    • This is the controller itself (drives external strobe lighting)
    • 24 VDC
    • Terminal block
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Omron / Sentech FLV-TCC3HB machine vision lighting
    • Trigger (strobe) and continuous lighting
    • IP20 (IEC 60529)
    • Drive: 0ch constant-current, 1ch/2ch constant-voltage; PWM duty 100 kHz / voltage adjustment, 255 levels
    • Up to 15 W (24 V external trigger lighting; 12 V continuous up to 7.5 W)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Basler Light Controller 2C-1.25A-50W-24V machine vision lighting
    • Current-controlled
    • 100–240 VAC input / 8–24 VDC output
    • 50 W (total output)
    • 0–40 °C
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • DCM Sistemes VSC3100B machine vision lighting
    • RGB (drives RGB / mixed colour lighting via 3 channels)
    • Strobe (stroboscopic) drive mode, per-shot current regulation
    • This is the controller itself (drives external strobe/RGB lighting)
    • +24 VDC ±3%
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Lighting cables

Industrial Lighting cables with locking connectors. Check length and flex rating against your installation.

All cables →
  • Opto Engineering LTCLHP016-W machine vision lighting
    • Telecentric (Telecentric lights)
    • White, 6000 K
    • Ø 20 mm (beam diameter)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Opto Engineering LTCLHP023-W machine vision lighting
    • Telecentric (Telecentric lights)
    • White, 6000 K
    • Ø 16 mm (beam diameter)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Opto Engineering LTCLHP024-W machine vision lighting
    • Telecentric (Telecentric lights)
    • White, 6000 K
    • Ø 30 mm (beam diameter)
    • Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Rosepetal · AI

Test this camera with Rosepetal

Validate your visual inspection with AI: send us sample images and we evaluate the case on your hardware.

AIS Vision · Integration

We validate camera + lens + lighting

AIS Vision defines and tests the optimal combination of camera, optics and lighting for your application before you buy.