Opto Engineering LTCLHP120-W telecentric illuminator — White, 6000 K, beam Ø 150 mm, WD 220–440 mm, 12-24 V, 2.5 W max, pulse current up to 2000 mA, M8 connector, length 408.4 mm, front diameter 180.0 mm, 4595 g.
Brand
Opto Engineering
Lighting type
Telecentric (Telecentric lights)
Color / wavelength
White, 6000 K
Available wavelengths
White, 6000 K
Color temperature
6000 K
Working distance
220–440 mm
Illuminated area
Ø 150 mm (beam diameter)
Supply voltage
12-24 V (tolerance ± 10%)
Power consumption
2.5 W max
Mode
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Connection
M8
Dimensions
Length 408.4 mm, front diameter 180.0 mm — nominal value, with no spacers in place
The LTCLHP120-W is a white telecentric illuminator in the LTCLHP high-performance series, providing 6000 K white light over an illuminated area of Ø 150 mm (beam diameter). Telecentric illumination is collimated, so the light stays close to parallel across the working distance, supporting silhouette and edge measurement with telecentric optics. The working distance of 220–440 mm sets the placement window, and the part should sit within it so the Ø 150 mm illuminated area covers the features being measured.
The unit is powered by 12-24 V (tolerance ± 10%) with a maximum consumption of 2.5 W. In continuous mode the maximum LED current is 350 mA; in pulsed mode the maximum pulse current is 2000 mA. Steady white light serves continuous imaging, and pulsed mode provides a higher peak current when the application calls for it. The M8 connector provides the electrical connection, and the cable routing and supply should be planned around it.
Mechanically the illuminator is 408.4 mm long with a front diameter of 180.0 mm, and it weighs 4595 g. These dimensions are nominal, with no spacers in place, so the installation envelope and the mounting structure need to accommodate them. The operating temperature range is 0–40 °C. The 6000 K white model is intended for backlit measurement where white light is preferred over a single color and where a Ø 150 mm illuminated area is needed.
Best for
Silhouette measurement under 6000 K white collimated light at a 220–440 mm working distance.
Gauging of parts that fit within a Ø 150 mm illuminated area.
Backlit inspection where white light is preferred over a single color.
Pulsed white backlighting at up to 2000 mA peak current for switched, higher-output illumination.
Selection notes
Choose a telecentric lens with a field of view inside the Ø 150 mm illuminated area and the 220–440 mm working distance.
Provide a 12-24 V supply with ±10% tolerance, sized for the 2.5 W maximum consumption.
Keep continuous operation at or below 350 mA LED current, and use pulsed mode, up to 2000 mA, where higher peak output is needed.
Allow for the 4595 g weight and 408.4 mm length, using nominal dimensions with no spacers in place, when designing the mount.
Check the trigger and I/O details in the manufacturer datasheet before finalizing the M8 cabling.
Specifications: General
Brand
Opto Engineering
Lighting type
Telecentric (Telecentric lights)
Specifications: Interface
Connection
M8
Specifications: Optical
Color / wavelength
White, 6000 K
Available wavelengths
White, 6000 K
Color temperature
6000 K
Working distance
220–440 mm
Specifications: Electrical
Supply voltage
12-24 V (tolerance ± 10%)
Power consumption
2.5 W max
Mode
Continuous / pulsed (max pulse current 2000 mA, max continuous LED current 350 mA)
Specifications: Environment
Operating temperature
0–40 °C
Specifications: Geometry
Illuminated area
Ø 150 mm (beam diameter)
Specifications: Mechanical
Dimensions
Length 408.4 mm, front diameter 180.0 mm — nominal value, with no spacers in place
Weight
4595 g
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.