The -4100 is the standard-resolution DX8210 in its Extended version, with the same 900 × 900 mm X-pattern reading area and 60° aperture angle as the DX8210-2100. The supply, dimensions, weight and interfaces are also the same, so compare the Extended reading window with the -2100 at your belt distance before choosing between them.
It is an omnidirectional 1D station: the X-pattern lets labels arrive at any angle, and it decodes 22 symbologies (2/5 family, Code 39, Code 93, Code 128, EAN/UPC, EAN 128, ISBN 128). For the network it provides embedded EtherNet/IP, PROFINET-IO and PROFIBUS-DP support, 2 Ethernet TCP/IP ports and RS232/RS422 with an aux RS232.
Best for
Packages with 1D labels at random orientation over a 900 × 900 mm area, where the narrowest bar is within the standard resolution class.
Mixed fieldbus sites that standardise on one scanner housing across EtherNet/IP, PROFINET-IO and PROFIBUS-DP controllers.
Installations replacing or adding to a DX8210-2100 station, since the supply, dimensions, weight and interfaces are the same and the wiring and frame space carry over.
Selection notes
If labels carry fine bars, the DX8210-4200 adds high resolution to the same Extended version.
The head needs 20–30 VDC at 20 W, so allow up to 20 W ÷ 20 V = 1.0 A at the low end of the range, and a frame for 7.7 kg.
1D symbologies only: use an imager for Data Matrix, QR or DPM marks.
Specifications: General
Brand
Datalogic
Reader type
Code reader
Form factor
Fixed-mount all-in-one omnidirectional reading station
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Availability
DX8210-4100 Standard Resolution Extended Base
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
1. Install the IMPACT Software Suite and connect the camera
Install the IMPACT Software Suite on your PC, which provides both the configuration/viewer tools and the SDK. For a GigE Vision model (E100, M or U series), connect it to a dedicated NIC and, for USB3 models, use a certified USB3 cable and port. Power the camera and confirm it enumerates.
2. Bring the camera online and verify the link
For GigE Vision, put the camera and the host NIC on the same subnet (a static IP on the camera matching the NIC range is the most reliable starting point); for USB3, confirm the device is recognized. Open the IMPACT viewer/device tool, discover the camera, and verify a stable connection before streaming. Enabling jumbo frames on the NIC helps GigE throughput.
3. Set exposure, gain and trigger, then grab a first image
In the IMPACT tools, start a live stream and adjust exposure and gain until the image is well-lit without saturation; set white balance on color models. Begin in free-run (continuous) mode to confirm imaging, then switch to hardware or software trigger as your application requires. Capture and save a reference image once the scene looks correct.
4. Build a vision tool or move to the SDK/API
Use the IMPACT point-and-click vision tools to assemble an inspection, or use the IMPACT SDK to access the camera and results programmatically and feed them into your HMI/PLC application. As these are GenICam/GenTL-compliant devices, you can alternatively drive them from any GenICam-compliant third-party vision library if your pipeline standardizes on one.
5. Route the stable feed to deep-learning inspection (optional)
Once you have a stable, repeatable image, the feed can be sent to a deep-learning inspection platform such as Rosepetal for defect detection or classification tasks that go beyond rule-based tooling. Keep lighting, optics and trigger timing fixed so the images reaching the model stay consistent.
Frequently asked questions
Both are standard resolution; the -4100 is the Extended version. The reading area, supply, size and interfaces match, so test the Extended version against your belt distance and the narrowest bar on your labels.
EtherNet/IP is embedded; PROFINET-IO and PROFIBUS-DP are supported. The two NPN outputs switch to 0 V, so check that the receiving input is wired for that polarity.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE