This is the fine-sampling member of the 1.6 MP family, and it pays with a narrow window. The 25 mm lens frames 36 × 27 mm at 200 mm, so one pixel covers 36 mm ÷ 1440 px = 0.025 mm and the rated minimum modules (0.04 mm for 1D, 0.05 mm for 2D) are only 1.6 px and 2.0 px. For production margin plan on about 0.075 mm (3 px). Focus covers 150–250 mm, so the code has to arrive in nearly the same place every cycle.
Motion is the other limit. At the rated 3 m/s a part crosses the 36 mm field in 36 mm ÷ 3000 mm/s = 12 ms, less than the 16.7 ms frame period at 60 fps, so trigger from part position. Keeping blur under one pixel at 3 m/s takes an exposure near 0.025 mm ÷ 3000 mm/s ≈ 8 µs, so for the smallest marks slow or stop the part. Decoding is AI-assisted (deep learning with multi-parameter polling) and the integrated red or white light is set by order code.
Best for
Fixtured stations such as nests or indexed tables, where each code lands in the same 36 × 27 mm window every cycle.
Small 2D marks held at a constant standoff near 200 mm, where a 0.05 mm module gets 2 px and a 0.075 mm module gets 3 px.
Shiny parts at close range, using the polarized red light option to keep glare off the code area.
Selection notes
The focus window is 100 mm deep. If part-height tolerance plus bracket drift can exceed it, or the code can sit anywhere in a wider area, R5016MG-16M reads 80–1500 mm over a 61 × 46 mm field at 200 mm, with coarser 0.042 mm pixels.
Scaling the 36 × 27 mm field roughly with distance gives about 27 × 20 mm at 150 mm and 45 × 34 mm at 250 mm (estimates), so check that the code fits at both ends of the range.
The 0.05 mm 2D minimum applies to order code R5016MG-25M-WGG01E; confirm it for the code you order if your marks are near that size.
Specifications: General
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
AI / deep learning
Built-in deep-learning algorithms and multi-parameters polling to ensure effects of complex applications
1D code 0.04 mm / 2D code 0.05 mm (stated for R5016MG-25M-WGG01E)
Specifications: Mechanical
Dimensions
82 × 55 × 53 mm (not including connector)
Weight
<350 g
Housing material
Aluminum alloy + Front cover
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Integrated lighting ●
Illumination colour ●
Min. code resolution ●
Availability
red light Base
Red, Polarized/Non-polarized
Red, Polarized/Non-polarized
—
On request
white light
White
White
1D code 0.04 mm / 2D code 0.05 mm
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
Yes. Software trigger, external trigger and free run are available, and the GPIO offers 2 opto-isolated inputs and 3 opto-isolated outputs for a part sensor and result signals.
The common linear symbologies (Code 39, Code 93, Code 128, Codabar, EAN-8/13, UPC-A/E, ITF-25, 2 of 5, GS1-128) and the 2D codes Data Matrix, Micro QR, GS1 DataMatrix and GS1 QR.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE