iRAYPLE R5016PMG-05M — R5000 Series fixed-mount code reader; 1.6 MP (1440 × 1080) at 60 fps; 5 mm auto-focus lens; read distance 25–2000 mm; min. code 1D code 0.02 mm / 2D code 0.037 mm; integrated red/white illumination; Ethernet, RS-232, PROFINET, EtherNet/IP, Digital I/O; IP67.
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
Scan technology
2D area imager (global shutter)
Supported codes
1D: Code 39/Code 93/Code128/CodaBar/EAN8/EAN13/UPCA/UPCE/ITF25/2of5 (Industrial2of5)/standard25/GS1-128 etc. and 2D: Data Matrix/MQR/GS1 DM/GS1QR/PDF417 etc.
Focus runs from 25 mm, where the 5 mm lens frames 17 × 13 mm, to 2000 mm, where the field is 1198 × 898 mm. On 1440 px that is about 0.012 mm per pixel up close (17 mm ÷ 1440) and 0.83 mm at 2000 mm (1198 mm ÷ 1440). The 0.037 mm 2D minimum is about 3.1 px at the near end, so it is a close-range figure; at 2000 mm, 3 px per module means modules of about 2.5 mm (3 × 0.83 mm), which suits large labels rather than small marks.
AI decoding is built in (deep-learning algorithms with multi-parameter polling, aimed at complex applications), the light is integrated and set by order code, and a green light signals the read result. The IP67 body is 57 × 37 × 39 mm and under 160 g.
Best for
Tight installations where the reader sits within a few centimetres of the part: it focuses from 25 mm and still frames 17 × 13 mm there.
Cartons or stacks of varying size read from 1–2 m, provided the labels use large modules (about 2.5 mm or more at 2 m).
Dusty or splash-exposed spots on small machines, where an IP67 body under 160 g is easier to mount than a larger reader.
Selection notes
A larger sensor with this lens widens the field without sharpening detail: R5030PMG-05M frames 25 × 19 mm at 25 mm and R5050PMG-05M 32 × 24 mm, with pixel size staying near 0.012 mm.
For small marks, R5016PMG-12M starts at 50 mm and reaches 0.014 mm 1D and 0.026 mm 2D minimum modules from a 12 × 9 mm near field.
The supply is 16–26 V DC at 1 A, so a 12 V rail is below its input range. Confirm the light variant (red or white; polarized, non-polarized or diffuse) when ordering.
Specifications: General
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
AI / deep learning
Built-in deep-learning algorithms and multi-parameters polling to ensure effects of complex applications
Specifications: Sensor
Resolution
1.6 MP (1440 × 1080)
Horizontal resolution
1440 px
Specifications: Performance
FPS
60 fps
Specifications: Interface
Communication
100M Ethernet; protocols: SDK,TCP Client,TCP Server,FTP,RS232,Profinet,Modbus,EtherNet/IP,MC(SLMP),FINS/UDP,FINS/TCP
Connection
2 Industrial M12 connectors support GigE and GPIO
Specifications: Optical
Field of view
17 mm × 13 mm – 1198 mm × 898 mm
Focal length
5 mm
Focus
Motorised auto focus (M10 lens)
Integrated lighting
Red, Polarized/Non-polarized; White,diffuse light · White, Polarized/Non-polarized/diffuse light — depending on order code
Illumination colour
Red, Polarized/Non-polarized; White,diffuse light · White, Polarized/Non-polarized/diffuse light — depending on order code
Specifications: Electrical
Supply voltage
16–26V DC, 1A input
Power consumption
<6 W(light included)
Specifications: Environment
IP rating
IP67
Operating temperature
-20 °C to +50 °C
Specifications: Reading
Scan technology
2D area imager (global shutter)
Supported codes
1D: Code 39/Code 93/Code128/CodaBar/EAN8/EAN13/UPCA/UPCE/ITF25/2of5 (Industrial2of5)/standard25/GS1-128 etc. and 2D: Data Matrix/MQR/GS1 DM/GS1QR/PDF417 etc.
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Integrated lighting ●
Illumination colour ●
Availability
red/white light Base
Red, Polarized/Non-polarized; White,diffuse light
Red, Polarized/Non-polarized; White,diffuse light
On request
white light
White, Polarized/Non-polarized/diffuse light
White, Polarized/Non-polarized/diffuse light
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
Only with a precisely timed trigger. In the 17 mm near field a part at 3 m/s crosses in 17 ÷ 3000 s ≈ 5.7 ms, less than the 16.7 ms frame period at 60 fps, so free run can miss it.
Up to 120 codes/s, triggered by software, external input or free run.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE