iRAYPLE R5016PMG-12M — R5000 Series fixed-mount code reader; 1.6 MP (1440 × 1080) at 60 fps; 12 mm auto-focus lens; read distance 50–2000 mm; min. code 1D code 0.014 mm / 2D code 0.026 mm; integrated red/white illumination; Ethernet, RS-232, PROFINET, EtherNet/IP, Digital I/O; IP67.
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
Scan technology
2D area imager (global shutter)
Supported codes
1D: Code 39/Code 93/Code128/CodaBar/EAN8/EAN13/UPCA/UPCE/ITF25/2of5 (Industrial2of5)/standard25/GS1-128 etc. and 2D: Data Matrix/MQR/GS1 DM/GS1QR/PDF417 etc.
Fine sampling starts at 50 mm. At the near limit the 12 mm lens frames 12 × 9 mm, so one pixel covers 12 mm ÷ 1440 px ≈ 0.0083 mm, and the rated minimums, 0.014 mm for 1D and 0.026 mm for 2D, are about 1.7 px and 3.1 px.
The cost is a small window: the code must sit inside 12 × 9 mm, so fixture repeatability and part rotation matter more than the reader. Backing off widens it without another lens: scaled roughly with distance (an estimate), the window is about 24 × 18 mm at 100 mm, with pixels of about 0.017 mm. Deep-learning decoding is built in, and the IP67 body works from −20 to +50 °C.
Best for
Small Data Matrix marks on compact components, read from 50 mm where one pixel covers only 0.0083 mm of the part.
Robot or axis mounting where payload counts: the body is 57 × 37 × 39 mm and under 160 g.
Stationary or indexed parts that can be held within a few millimetres, so the code stays inside the 12 × 9 mm window at 50 mm.
Selection notes
If code height varies between parts, R5016PMG-12L adds ToF-assisted liquid-lens focus from 90 mm to 2000 mm.
For the same detail over a wider window, R5050PMG-12M frames 21 × 16 mm at 50 mm with the same minimums, at 50 fps instead of 60 and 100 codes/s instead of 120.
Fine marks depend on contrast: test the light option (red or white; polarized, non-polarized or diffuse) on your worst surface before ordering.
Specifications: General
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
AI / deep learning
Built-in deep-learning algorithms and multi-parameters polling to ensure effects of complex applications
Specifications: Sensor
Resolution
1.6 MP (1440 × 1080)
Horizontal resolution
1440 px
Specifications: Performance
FPS
60 fps
Specifications: Interface
Communication
100M Ethernet; protocols: SDK,TCP Client,TCP Server,FTP,RS232,Profinet,Modbus,EtherNet/IP,MC(SLMP),FINS/UDP,FINS/TCP
Connection
2 Industrial M12 connectors support GigE and GPIO
Specifications: Optical
Field of view
12 mm × 9 mm – 516 mm × 387 mm
Focal length
12 mm
Focus
Motorised auto focus (M10 lens)
Integrated lighting
Red, Polarized/Non-polarized; White,diffuse light · White, Polarized/Non-polarized/diffuse light — depending on order code
Illumination colour
Red, Polarized/Non-polarized; White,diffuse light · White, Polarized/Non-polarized/diffuse light — depending on order code
Specifications: Electrical
Supply voltage
16–26V DC, 1A input
Power consumption
<6 W(light included)
Specifications: Environment
IP rating
IP67
Operating temperature
-20 °C to +50 °C
Specifications: Reading
Scan technology
2D area imager (global shutter)
Supported codes
1D: Code 39/Code 93/Code128/CodaBar/EAN8/EAN13/UPCA/UPCE/ITF25/2of5 (Industrial2of5)/standard25/GS1-128 etc. and 2D: Data Matrix/MQR/GS1 DM/GS1QR/PDF417 etc.
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Integrated lighting ●
Illumination colour ●
Availability
red/white light Base
Red, Polarized/Non-polarized; White,diffuse light
Red, Polarized/Non-polarized; White,diffuse light
On request
white light
White, Polarized/Non-polarized/diffuse light
White, Polarized/Non-polarized/diffuse light
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
The rated minimum is 0.026 mm, about 3.1 px at the 50 mm near limit. At roughly 100 mm a pixel is about 0.017 mm, so 3 px per module needs modules of about 0.05 mm.
Two industrial M12 connectors carry network and GPIO, with RS232 and 2 opto-isolated inputs and 3 opto-isolated outputs. Protocols include PROFINET, EtherNet/IP, Modbus, TCP and FTP.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE